DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

ProcessLogix R500.1 Selection Guide

From:A-B | Author:LIAO | Time :2025-08-13 | 1419 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Enhancements Description

Engineering Tools Enhancements • History Configuration

• Cross Reference and Wiring Improvement

• Compare Parameters

• SCM Memory Enhancements

• Server Scripting

Server Enhancements

New Alarm/Event subsystem • Flexible filtering, sorting and layout

• Common presentation for Alarms, Events, Journal, etc.

Updated Station & HMIWeb Display Builder • Improved menu/toolbar configuration

• Support for IKB/OEP Operator keyboards

• Define which monitor to start on, on multi-monitor systems.

• Faceplates

• Chart object

• Hyperlink support

• Rotation of static text on HMIWeb displays

• Third-party HTML displays

• Simplified appearance of HMIWeb object model in script editor

• Multiple Static Stations

Plant Data Model Enhancements • Supports 40 character Point ID's

Updated OPC Support • OPC Alarm and Event Server

Windows 2000 Security • Optionally allows the use of Windows user accounts for ProcessLogix 

operators.

Updated System Displays • Supports screen resolutions of 1280x1024

Updated Application Development • Service Pack 5 for Microsoft Visual Studio v6.0 has been qualified for 

use with ProcessLogix.

• Includes Microsoft Visual C/C++ v6.0 and Microsoft Visual Basic v6.0.

Hardware Enhancements

Additional Module Support The following modules have been qualified for use with ProcessLogix:

• 1756-ENET/B

• 1756-ENB/T

• 1794-IF4I

• 1794-OF4I

• 1756-DNB

• 1757-ABRIO

Engineering Tools 

Enhancements

Server Enhancements New Alarm/Event subsystem

The new Alarm/Event subsystem in this release of ProcessLogix can manage 

notifications from ProcessLogix and third party OPC systems. The alarm 

management presentation includes common presentation components for 

Alarms, Messages, Journal, etc. based on HMIWeb technologies. These 

displays support flexible filtering, sorting and layout. This new subsystem 

utilizes Microsoft's SQL Server for the Event Store. Optional journalling of 

full user name is also supported.

Table 1.B Enhancements to Engineering Tools 

Enhancement Description

History Configuration Historical data collection, Group display assignment, and Trend 

display assignment are now standard part of CB point 

configuration.

Cross Reference and 

Wiring Improvement

This feature improves the wiring algorithm and results in better 

wiring paths during control configuration. The cross reference 

provides an optional wire label that clearly identifies wire paths 

as they cross page boundaries.

Compare Parameters This enhancement is provided as an option during download of a 

CM/SCM or selection of CMs/SCMs. It allows reading 

parameters from the controller and comparing them with the 

Monitoring or Project version. If this option is selected, a dynamic 

form shows all parameters that differ; each of them has a 

selection box indicating if the user wants to override the value or 

not. Those parameters selected to override are sent to the 

controller.

SCM Memory 

Enhancements

CEE memory is now optimized for the actual contents of SCM 

expressions instead of a maximum sized allocation, resulting in a 

memory savings of 30-35% for the average sized SCM 

configuration.

Server Scripting Server scripts can now be attached to CM's. Server Scripts allow 

VBScript to be executed based on events happening on 

ProcessLogix like a CM going into Alarm or parameter of a CM 

changing.

Updated Station & HMIWeb Display Builder

The following updates have been made to Station & HMIWeb Display Builder: 

• Improved menu/toolbar configuration

• Support for IKB/OEP Operator keyboards

• Define which monitor to start on, on multi-monitor systems.

• Faceplates - does not depend on hard-coded references to data, instead, 

links to point when called up. “Pin” function allows pop-up to stay open 

even after underlying display is changed. Includes pre-built faceplates 

for 1757-PLX52 and Standard points.

• Chart object

• Hyperlink support

• Rotation of static text on HMIWeb displays

• Alarm object

The following updates have been made to HMIWeb Display Builder:

• Ability to edit HTML pages created in third-party tools in HMIWeb 

Display Builder.

• Simplified appearance of HMIWeb object model in script editor

• The licensing for Stations has been changed so that up to four Station 

windows can be opened from the same machine and these four Station 

windows only count as one Station License. Works only with Stations 

that have a reserved (static) connection to the server, i.e. not for rotary 

Station connections or Web browsers.

TIP The 1757-PLX52 faceplates are provided in a zipped 

package per faceplate. To use these faceplates, double-click 

on the related package in the displays directory to extract 

the files from the package.

Plant Data Model Enhancements

This release of ProcessLogix has been enhanced to support 40 character Point 

ID's (standard points only, i.e. analog, status, accumulator). Point descriptor 

and area codes have been lengthened to support 132 and 40 characters 

respectively. Users using the ProcessLogix ODBC Driver for reports or 

  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 8DIO / 2UAI
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500S-27-1550 Slice I/O, RS232/485. 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1550 Slice I/O, RS232/485. 8DIO / 2UAI
  • CTI 2500S-23-1550 Slice I/O, RS232/485. 4DI / 4DO / 2UAI / 2AO
  • CTI 2500S-27-1050 Slice I/O, Ethernet, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1050 Slice I/O, Ethernet, 8DIO / 2UAI
  • CTI 2500S-23-1050 Slice I/O, Ethernet, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500C-32F-CJC 32-Pin Field Wiring Connector with Cold Junction Compensation
  • CTI 2500C-32F 32-Pin Field Wiring Connector
  • CTI 2500C-8-TC Eight Thermocouple Inputs
  • CTI 2500C-8-RTD Eight RTD Inputs
  • CTI 2500C-8-RL-FC 8 Form-C Relay Outputs
  • CTI 2500C-8-IDO-24V 8 Isolated 24VDC Outputs
  • CTI 2500C-8-IDO-120V 8 Isolated 120VAC Outputs
  • CTI 2500C-16-DO-24V Sixteen 24VDC Digital Outputs
  • CTI 2500C-16-DO-120V Sixteen 120VAC Digital Outputs
  • CTI 500C-16-IDI-24V Sixteen Isolated 24V AC/DC Digital Inputs
  • CTI 2500C-16-IDI-120V Sixteen Isolated 120V AC/DC Digital Inputs
  • CTI 2500C-16-DIDO-SIM Sixteen Digital Input and Output SImulator
  • CTI 2500C-16-DI-24V Sixteen 24V AC/DC Digital Inputs
  • CTI 2500C-16-DI-120V Sixteen 120V AC/DC Digital Inputs
  • CTI 2500C-RBC-RS485 RS485 Remote Base Controller
  • CTI 2500C-RBC-PRF Profibus Remote Base Controller
  • CTI 2500C-PS-24V-35 35-Watt DC Power Supply
  • CTI 2500C-PS-120V-35 35-Watt AC Power Supply
  • CTI 2500C-R8 Eight-Slot Base
  • CTI 2500C-R4 Four-Slot Base
  • CTI 2500C-R16 Sixteen-Slot Base
  • CTI 2500C-2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2500C-J750 Compact Janus PAC with 3MB Project Memory
  • CTI 2500C-C300 CPU with 512K User Memory
  • CTI 2500C-C200 CPU with 256K User Memory
  • CTI 2500C-C100 CPU with 128K User Memory
  • CTI 2500C-8-AO 8 Analog Outputs
  • CTI 2500C-8-AI 8 Analog Inputs
  • CTI 2559-FCAL Precision Calibration Connector
  • CTI 2559-FPC 40-Position Screw-Terminal Connector
  • CTI 2500-RFC PLC to RF Modem Cable
  • CTI 2500-40F 40-Position Standard Screw-Terminal Connector
  • CTI 2505 Vibration Sensor Interface Module
  • CTI 2554-A 4-Channel Isolated High Speed Counter Module
  • CTI 2553-A 2-Channel Mag Meter Input Module
  • CTI 2502 2-Channel High Speed Counter Input Module
  • CTI 2559-TC 8-Channel Thermocouple Input Module
  • CTI 2556-A 16-Channel Isolated Thermocouple Input Module
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2551-A 8-Channel Isolated Thermocouple Input Module
  • CTI 2559-RTD 8-Channel RTD Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2557 16-Channel RTD Input Module
  • CTI 2552-A 8-Channel Isolated RTD Input Module
  • CTI 2534 8-Point Form-C Relay Output Module
  • CTI 2532 16-Point Form-A Relay Output Module
  • CTI  2531 32-Point Form-A Relay Output Module
  • CTI  2530 8-Point Form-C Relay Output Module
  • CTI  2562 8-Channel Analog Output Module
  • CTI  2560-A 8-Channel Isolated Analog Output Module
  • CTI  2501 8in/4out Analog Module
  • CTI  2558 8-Channel Analog Input Module
  • CTI  2555-A 16-Channel Analog Input Module
  • CTI  2550-A 8-Channel Isolated Analog Input Module
  • CTI  2599 8/16/32-Point AC Output Module
  • CTI  2598-8 8-Point AC Output Module
  • CTI   2598 8/16-Point AC Output Module
  • CTI   2597 8/16/32-Point DC Output Module
  • CTI 2596-8 8-Point DC Output Module
  • CTI 2596 8/16-Point DC Output Module
  • CTI 2595 16-Point TTL/Word Output Module
  • CTI 2591-EF 16-Point Isolated 11-146 VDC Output with Front Panel Accessible Fuses
  • CTI 2591-A 16-Point Isolated 11-146 VDC Output Module
  • CTI 2590-EF 16-Point Isolated 20-132 VAC Output with Front Panel Accessible Fuses
  • CTI 2590-A 16-Point Isolated Discrete 20-132 VAC Output Module
  • CTI 2589-B 8/16/32-Point Universal Discrete Input Module
  • CTI 2589-A 8/16/32-Point Universal Discrete Input Module
  • CTI 2588-8 8-Point Universal Discrete Input Module
  • CTI 2585 16-Point TTL/Word Input Module
  • CTI 2582 16-Point Isolated 125 VDC Input Module
  • CTI 2581 16-Point Isolated 12-56 VDC Input Module
  • CTI 2580 16-Point Isolated 95-132 VAC Input Module
  • CTI 2500-TAP RS485 Network Tap
  • CTI 2500-RIO-B RS485 Remote Base Controller
  • CTI 2500-RIO-A RS485 Remote Base Controller
  • CTI 2500-RBC Profibus Remote Base Controller
  • CTI 2515-A 100-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2515 100-Watt AC Power Supply (MATURE - replaced by 2515-A)
  • CTI 2513-A 75-Watt DC Power Supply with Redundancy Support
  • CTI 2513 75-Watt 24VDC Power Supply
  • CTI 2512-A 75-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2512 75-Watt AC/DC Power Supply
  • CTI 2510 125 VDC Power Supply
  • CTI 2500-SSB Single Slot Blank Front Panel
  • CTI 2500-R11-A Eleven-Slot Redundant Base
  • CTI 2500P-R16 Sixteen-Slot Base with High-Speed Channel
  • CTI 2500P-R8 Eight-Slot Base with High-Speed Channel
  • CTI 2500P-R4 Four-Slot Base with High-Speed Channel
  • CTI 2541 Redundant Processor Manager Module
  • CTI 2577 Profibus DP Slave Adapter
  • CTI 2573-MOD Serial Interface Adapter with MODBUS
  • CTI 2572-AF Fast Ethernet TCP/IP Adapter with Optical Fiber Connection
  • CTI 2572-A Fast Ethernet TCP/IP Adapter
  • CTI 2572 Ethernet TCP/IP Adapter
  • CTI 2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2576 DeviceNet™ Scanner Module (MATURE)
  • CTI 2500P-ECC1 Ethernet Communications Coprocessor
  • CTI 2500P-JACP Janus Application Coprocessor
  • CTI 2500P-ACP1 Application Coprocessor (MATURE - replaced by 2500P-JACP)
  • CTI 2500P-J450 Janus PAC with 2MB Project Memory
  • CTI 2500-C400 CPU with 3072K User Memory
  • CTI 2500-C300 CPU with 512K User Memory
  • CTI 2500-C200 CPU with 256K User Memory
  • CTI 2500-C100 CPU with 128K User Memory
  • CTI 2500P-J750 Janus PAC with 3MB Project Memory
  • Shinkawa WHF3006M Displacement Converter
  • Shinkawa JBP-220 (P-24-94A / P-24-94B) Circuit Board Module
  • SHINKAWA   WKN-142K5  2-WIRE VIBRATION TRANSDUCER
  • Shinkawa FRP-321 (P-26-54A / P-26-54B) Circuit Board Module
  • Shinkawa IOP-160 (P-25-72A / P-25-72B) Circuit Board Module
  • Shinkawa PK-147B-1 / PK-147A-1 Circuit Board Module
  • Shinkawa CPP-91A Circuit Board Module
  • Shinkawa FRP-177 PCB Module
  • Shinkawa CPP-127 (P-26-74A / P-26-74B) Circuit Board Module
  • Shinkawa FRP-227 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa MDP-104 (P-25-83A / P-25-83B) Circuit Board Controller
  • Shinkawa VK-143P2 High-precision eddy current sensor driver/signal conditioner
  • Shinkawa FRP-226 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa CPP-107A P-22-99A P-22-99B Circuit Board Module