Rated surge volt.(Vsurge) .................................................... 2.5 kV
and 400 Vac [4] Rated (Vrated) .......................................... 277/480 Vac
Max. value (Vmax) ......................................... 346/600 Vac
Rated surge volt.(Vsurge) .................................................... 4.0 kV
Accuracy .......................................................................................... Class 1
Measurable alternator windings ..................... 3p-3w, 3p-4w, 1p-2w, 1p-3w
Setting range ..................... primary .................................50 to 650.000 Vac
Linear measuring range .............................................................. 1.25×Vrated
Measuring frequency................................................50/60 Hz (40 to 85 Hz)
High Impedance Input; Resistance per path ....... [1] 0.498 MΩ, [4] 2.0 MΩ
Max. power consumption per path ................................................ < 0.15 W
Current (Isolated) Rated (Irated) .............................. [1] ../1 A or [5] ../5 A
Linear measuring range ....................................................... Igen = 3.0×Irated
Imains/ground = 1.5×Irated
Setting range .......................................................................... 1 to 32.000 A
Burden .......................................................................................... < 0.15 VA
Rated short-time current (1 s) ................................ [1] 50×Irated, [5] 10×Irated
Power .........................................................................................................
Setting range .......................................................... 0.5 to 99.999.9 kW/kvar
Discrete inputs .............................................................................. isolated
Input range ............................................................. 12/24 Vdc (8 to 40 Vdc)
Input resistance .............................................................. approx. 20 kOhms
Power supply .......................................................... 12/24 Vdc (8 to 40 Vdc)
Intrinsic consumption .................................................................. max. 17 W
Ambient temperature (operation) ....................... -20 to 70 °C / -4 to 158 °F
Ambient temperature (storage) ........................ -30 to 80 °C / -22 to 176 °F
Ambient humidity ...................................................... 95 %, non-condensing
Voltage ............................................................................................... ( /Δ)
100 Vac [1] Rated (Vrated) ............................................ 69/120 Vac
Max. value (Vmax) ........................................... 86/150 Vac
Rated surge volt.(Vsurge) .................................................... 2.5 kV
and 400 Vac [4] Rated (Vrated) .......................................... 277/480 Vac
Max. value (Vmax) ......................................... 346/600 Vac
Rated surge volt.(Vsurge) .................................................... 4.0 kV
Accuracy .......................................................................................... Class 1
Measurable alternator windings ..................... 3p-3w, 3p-4w, 1p-2w, 1p-3w
Setting range ..................... primary .................................50 to 650.000 Vac
Linear measuring range .............................................................. 1.25×Vrated
Measuring frequency................................................50/60 Hz (40 to 85 Hz)
High Impedance Input; Resistance per path ....... [1] 0.498 MΩ, [4] 2.0 MΩ
Max. power consumption per path ................................................ < 0.15 W
Current (Isolated) Rated (Irated) .............................. [1] ../1 A or [5] ../5 A
Linear measuring range ....................................................... Igen = 3.0×Irated
Imains/ground = 1.5×Irated
Setting range .......................................................................... 1 to 32.000 A
Burden .......................................................................................... < 0.15 VA
Rated short-time current (1 s) ................................ [1] 50×Irated, [5] 10×Irated
Power .........................................................................................................
Setting range .......................................................... 0.5 to 99.999.9 kW/kvar
Discrete inputs .............................................................................. isolated
Input range ............................................................. 12/24 Vdc (8 to 40 Vdc)
Input resistance .............................................................. approx. 20 kOhms
Measuring
Generator voltage (3-phase/4-wire)
Generator current (3x true r.m.s.)
Mains voltage (3-phase/4-wire)
Mains or ground current (1x true r.m.s.) #1
Busbar voltage (1-phase/2-wire)
Control
Breaker control logic (open and closed transition) FlexAppTM 2 2 2 2
Automatic, Manual, Stop, and test operating modes
Single and multiple-unit operation
Mains parallel multiple-unit operation (up to 32 units) #2
AMF (auto mains failure) and stand-by operation