DCS; Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
AMAT 0330-1586A   Serial Communication PCB
❤ Add to collection

AMAT 0330-1586A Serial Communication PCB

AMAT 0330-1586A   Serial Communication PCB

5874.00
¥4601.00
¥4601.00
¥4601.00
Weight:2.000KG
Description

AMAT 0330-1586A   Serial Communication PCB


AMAT 0330-1586A is a specialized P1-OCTAL Communication Controller Board (also identified by manufacturer number 91516142) utilized within the control architecture of Applied Materials semiconductor tools.

Often paired with the 0350-1588B distribution interface, this board is a critical node for high-speed serial communication and data distribution across the tool's mainframe and processing chambers.

Technical Parameter Table

ParameterSpecification
Part Number0330-1586A
Manufacturer P/N91516142
Model NameP1-OCTAL Controller
Product TypeSerial Communication PCB
ArchitectureOctal-Channel RS-232/RS-485
Bus InterfaceProprietary AMAT / P1 Architecture
CompatibilityEndura, Centura, and P5000 Systems
Associated Parts0350-1588B (Distribution Board)

Related Models

These boards are typically part of a multi-board communication stack found in AMAT control racks:

0350-1588B: The primary interface board used in conjunction with the 0330-1586A.

0100-76091: SBC/WPS/CF Distribution Board.

0100-76100: VME Monitor Board.

0330-40753: Higher-density communication variant for later tool revisions.

Application Cases

The 0330-1586A is essential for synchronizing high-speed hardware tasks in a vacuum environment:

Serial Device Coordination: Managing the communication between the tool's master CPU and eight (Octal) peripheral devices such as robot controllers, chillers, and remote I/O modules.

Legacy Mainframe Support: Providing the serial logic necessary for the Centura 5200 and Endura 5500 toolsets to execute precise wafer transfer sequences.

Data Logging: Facilitating real-time feedback from chamber-level sensors to the tool's graphical user interface (GUI) for process monitoring.

Product Advantages and Features

Eight-Channel Density: Consolidates eight independent serial channels onto a single P1 card, significantly reducing the required rack space.

High-Speed Throughput: Optimized for the low-latency communication required for real-time semiconductor process control.

Industrial Reliability: Built to withstand the 24/7 duty cycles of a high-volume manufacturing (HVM) fab.

Error Correction: Features onboard hardware logic to minimize signal noise and data packet loss over long cable runs in the sub-fab.

Other Models in the Same Series

The 0330 Series encompasses various communication and logic boards:

0330-00100 Series: Early generation serial interface cards.

0330-31950: Enhanced communication modules for 300mm transition platforms.

0330-1586A: The standard revision for Octal P1 communication.

YASKAWAMB-01
YASKAWAPS-01
YASKAWASGDS-08A01A
YASKAWACP-317/AI-01
YASKAWAJACP-317800
YASKAWAJANCD-XIO01
YASKAWAJANCD-XTU01B
YASKAWADDSCR-R84H
YASKAWAJAPMC-IQ2303
YASKAWACACR-02-TE1K
YASKAWAPCCF-H64MS   64MB
YASKAWAJGSM-06
YASKAWAJAMSC-B2732V
YASKAWACACR-SR07BE12M
YaskawaJZNC-XPP02B
YASKAWAUSAHEM-02-TE53
YOKOGAWAF3BU06-0N
YOKOGAWAF3LC21-1N
YOKOGAWAF3NC01-0N
YOKOGAWAF3NC02-0N
YOKOGAWAF3PU06-0N
YOKOGAWAF3PU10-0N

Installation and Maintenance

Installation: Align the board with the card-cage guide rails. Ensure the P1 backplane connector is free of debris before seating. Firmly press until the ejector handles lock.

Maintenance: Due to the age of this architecture, check for "fretting" corrosion on the gold contact pins. Clean the edge connectors with an electronics-grade solvent if the system reports serial communication "Timeouts" or "Checksum Errors."

Configuration: Note that the 0330-1586A may require specific jumpers or dip-switch settings to define the baud rate and address for each of the eight channels.

ESD Caution: This board uses high-speed CMOS logic. Always wear a grounded ESD wrist strap when handling the unit.

Unique Product Description

The AMAT 0330-1586A (91516142) is the "eight-way translator" of the Applied Materials control system.

In a world where sub-second timing is the difference between a high-yield wafer and a total loss, this Octal board ensures that the central brain stays in perfect contact with every peripheral device on the tool.

Its robust design and high-density architecture make it a vital component for keeping veteran AMAT systems operating with modern-day reliability.


  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management Simplifying Optical Networks
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • Ethernet Modules EI 802F ABB
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • ABB AC 800F Controller Redundancy
  • ABB Freelance800F AC800F Data Sheet
  • ABB Compact control system replaces PLCs using AC 700F
  • ABB Triguard SC300E MSR04XI