VIBRO-METER   IOCN  200-585-000-321 I/O Interface Card
❤ Add to collection

VIBRO-METER IOCN 200-585-000-321 I/O Interface Card

VIBRO-METER   IOCN  200-585-000-321 I/O Interface Card

¥12540.00
¥11250.00
¥11250.00
¥11250.00
Weight:2.000KG
Description

VIBRO-METER   IOCN  200-585-000-321 I/O Interface Card






VIBRO-METER   IOCN  200-585-000-321 I/O Interface Card

Different versions of the MPC4 card

The MPC4 machinery protection card is available in different versions, including a standard

version, a separate circuits version and a safety (SIL) version.

NOTE: Both the standard and the safety (SIL) versions of the MPC4 card are certified to

IEC61508 and ISO13849. The MPC4SIL version was developed to permit a wider

range of installation options.

The original IEC61508 and ISO13849 certification process targeted a VM600 rack for

safety-related system (SRS) applications with a limited range of cards, that is, standard

MPC4/ IOC4T card pairs and RLC16 relay cards (see4.1.1Standard version of the MPC4).

Then Meggitt vibro-meter® (MeggittSA) decided to safety certify another system with

additional functionality, such as monitoring. To safety certify such a VM600 rack, it was

necessary to ensure that there is no possibility of the configuration being inadvertently

modified. The safety version of the MPC4 card (MPC4SIL) overcomes this potential

configuration issue by not implementing a VME bus interface, so data corruption via the

VM600 rack backplane’s VME bus is impossible.

4.1.1Standard version of the MPC4

The standard MPC4 card is the original version, intended for systems using a VM600 rack

with a limited range of cards, that is, standard MPC4/ IOC4T card pairs and RLC16 relay

cards.

The standard MPC4 has a VME-compatible slave interface and is software configurable via

RS-232 (on the panel of the MPC4 card) or via VME for a networked VM600 rack. It also

supports all processing modes (see Table7-1).

4.1.2Separate circuits version of the MPC4

The separate circuits version of the MPC4 card is intended for systems using a separate

circuits version of the VM600 rack. The separate circuits MPC4 was developed in accordance

with the CEI/IEC60255-5 standard: “Insulation coordination for measuring relays and

protection equipment – Requirements and tests” and has slightly different circuitry

(see9.10Grounding options).

Like the standard MPC4. the separate circuits MPC4 has a VME-compatible slave interface

and is software configurable via RS-232 (on the panel of the MPC4 card) or via VME for a

networked VM600 rack. It also supports all processing modes (see Table7-1).

4.1.3Safety version of the MPC4

The safety (SIL) version of the MPC4 card, that is the MPC4SIL, was developed to permit a

wider range of installation options with a single VM600 rack, for example, condition

monitoring in addition to machinery protection. To safety certify these systems, it was

necessary to ensure that the safety MPC4 is isolated from the other cards in a VM600 rack,

so that there is no possibility of its configuration being inadvertently modified.

As the safety MPC4 (MPC4SIL) does not have a VME bus interface, corruption of its

configuration is impossible as it is only software configurable via RS-232 (on the panel of the

MPC4 card). Therefore, it is now possible to define a single VM600 rack configuration

containing condition monitoring cards (such as the XMx16) and relay cards (such as the IRC4

and RLC16) in addition to safety-related machinery protection in the form of safety MPC4

cards.

However, the safety MPC4 card (MPC4SIL) does not support all of the processing modes

supported by the standard and the separate circuits versions of the MPC4 cards (see

Table7-1). For example, the MPC4SIL card does not support the speed/phase reference

(tachometer) input channels, the Narrow Band (Tracking) Vibration and Smax processing

functions, and it does not support the danger bypass (DB), trip multiply (TM) and channel

inhibit functions.

In addition, the use of standard MPC4 cards or safety MPC4 cards in a machinery monitoring

system for a safety-related application requires that the complete system configuration is

manually reviewed in order to:

• Ensure that the VM600 rack configuration is permitted.

• Avoid possible conflict from additional cards.

• Ensure that the MPC4 cards’ configurations are permitted.

NOTE: Refer to the VM600safety manual for further information.

4.1.4 Identifying different versions of the MPC4 card

The different versions of the MPC4 card can be visually identified from their panels, as the

lower handle on the panel is different.

• For the standard and separate circuits versions of the MPC4 card, the label on the lower

handle of the panel displays the text “MPC4” against a blue background, as shown in

Figure4-1(a).

• For the safety (SIL) version of the MPC4 card, the label on the lower handle of the panel

displays the circular TÜVNord logo and text “MPC4” against an orange background, as

shown in Figure4-1(b).

The ordering number (PNR) for a MPC4 card is in given in the format 200-510-SSS-xHh.

In this PNR, x represents the version of the MPC4 card as follows:

• 1 indicates the standard version of the card.

• 2 indicates the separate circuits version of the card.

• 3 indicates the safety (SIL) version of the card.

HirschmannRS20-0800M4M4SDBEHH
HirschmannRS30-0802OOZZSDAEHH
HirschmannMS20-1600SABEHH
HirschmannMM20-T1T1T1T1SBHH
HirschmannMM20-Z6Z6Z6Z6SBHH
TRICONEX3721
TRICONEX3009
TRICONEX3009X
METRIX5485C-006
HONEYWELLFC-SDO-0824 CC V1.5
BrannstromBilgMon 488 4A-2936 (15ppm / 220v 60hz)
B&R3cp340.60-2
B&R3cp340.60-2
ABBPCD235
HoneywellCC-TAIX51 51307075-175
HoneywellCC-PAIH51 51410069-275
HoneywellCC-TAIX51 51307075-175
HoneywellCC-PAIH51 51410069-275
REGINE28D-S




  • SAUTER AXT 201. 211: Thermal actuator for unit valves with stroke
  • SAUTER AXS 215S: Continuous actuator for unit valves, with stroke
  • SAUTER AXM 217S: Motorised actuator for unit valves with positioner
  • SAUTER AVM 321S, 322S: Valve actuator
  • SAUTER AVM234S: SUT valve actuator with positioner
  • SAUTER AVM 105. 115: Valve actuator
  • SAUTER AVF 234S: SUT valve actuator with spring return
  • SAUTER AVF124: Actuator with spring return
  • SAUTER AKM115SAF332: Smart Actuator for ball valve, BACnet/IP
  • SAUTER AKM115SA: Smart Actuator for ball valve
  • AKM 105S, 115S: Rotary actuator with SAUTER Universal
  • SAUTER AKM 105. 115: Rotary actuator for ball valve
  • SAUTER AVM 234S: SUT valve actuator with positioner
  • SELSEL-T401L Ultra-High-Speed Line Relay
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-787 Transformer Protection Relay
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL-487E Transformer Protection Relay
  • SEL-400G Advanced Generator Protection System
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700BT Motor Bus Transfer Relay
  • CTI 2500 Series® Slice Ethernet Remote I/O System
  • CTI 2500 Series® Compact Programmable Automation Control System
  • CTI 2500 Series® Classic Programmable Automation Control System
  • CTI 2500 Series® Bases
  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • EATON Instructions for the FP-5000
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671