Phoenix 2904622 QUINT4-PS/3AC/24DC/20 - Power supply
2904622 QUINT4-PS/3AC/24DC/20 - Power supply
Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 3-phase, output: 24 V DC/20 A
The fourth generation of the high-performance QUINT POWER power supplies ensures superior system availability by means of new functions.
Signaling thresholds and characteristic curves can be individually adjusted via the NFC interface.
The unique SFB technology and preventive function monitoring of the QUINT POWER power supply increase the availability of your application.
Control input (configurable) Rem Output power ON/OFF (SLEEP MODE)
Default Output power ON (>40 kΩ/24 V DC/open bridge between Rem and SGnd)
AC operation
Network type Star network
Nominal input voltage range 3x 400 V AC ... 500 V AC
2x 400 V AC ... 500 V AC
Input voltage range 3x 400 V AC ... 500 V AC -20 % ... +10 %
2x 400 V AC ... 500 V AC -10 % ... +10 %
Typical national grid voltage 400 V AC
480 V AC
Voltage type of supply voltage AC
Inrush current typ. 2 A (at 25 °C)
Inrush current integral (I2t) < 0.1 A2s
Inrush current limitation 2 A (after 1 ms)
AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
Mains buffering time typ. 33 ms (3x 400 V AC)
typ. 33 ms (3x 480 V AC)
Current consumption 3x 0.99 A (400 V AC)
3x 0.81 A (480 V AC)
2x 1.62 A (400 V AC)
2x 1.37 A (480 V AC)
3x 0.8 A (500 V AC)
2x 1.23 A (500 V AC)
Nominal power consumption 541 VA
Protective circuit Transient surge protection; Varistor, gas-filled surge arrester
Power factor (cos phi) 0.94
Switch-on time < 1 s
Typical response time 300 ms (from SLEEP MODE)
Recommended breaker for input protection 3x 4 A ... 20 A (Characteristic B, C or comparable)
Recommended fuse for input protection ≥ 300 V AC
Discharge current to PE < 3.5 mA
1.7 mA (550 V AC, 60 Hz)
DC operation
Nominal input voltage range ± 260 V DC ... 300 V DC
Input voltage range ± 260 V DC ... 300 V DC -13 % ... +30 %
520 V DC ... 600 V DC -13 % ... +30 % (mid-point earthed)
Voltage type of supply voltage DC
Current consumption 1.23 A (± 260 V DC)
1.06 A (±300 V DC)
Recommended breaker for input protection 1x 6 A (10 x 38 mm, 30 kA L/R = 2 ms)
Recommended fuse for input protection ≥ 1000 V DC
Efficiency typ. 93.9 % (400 V AC)
typ. 93.8 % (480 V AC)
Output characteristic U/I Advanced
Smart HICCUP
FUSE MODE
Nominal output voltage 24 V DC
Setting range of the output voltage (USet) 24 V DC ... 29.5 V DC (constant capacity)
Nominal output current (IN) 20 A
Static Boost (IStat.Boost) 25 A
Dynamic Boost (IDyn.Boost) 30 A (5 s)
Selective Fuse Breaking (ISFB) 120 A (15 ms)
Magnetic circuit breaker tripping A1...A16 / B2...B13 / C1...C6 / Z1...Z16
Derating > 60 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance ≤ 35 V DC
Protection against overvoltage at the output (OVP) ≤ 32 V DC
Control deviation < 0.5 % (Static load change 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, (10 Hz))
< 0.25 % (change in input voltage ±10 %)
Residual ripple < 60 mVPP (with nominal values)
Short-circuit-proof yes
No-load proof yes
Output power 480 W
600 W
720 W
Apparent power 686 VA (400 V, UOUT = 24 V, IOUT = stat. Boost)
698 VA (480 V, UOUT = 24 V, IOUT = stat. Boost)
Maximum no-load power dissipation < 7 W (400 V AC)
< 7 W (480 V AC)
Power loss nominal load max. < 32 W (400 V AC)
< 33 W (480 V AC)
Power dissipation SLEEP MODE < 5 W (400 V AC)
< 5 W (480 V AC)
Crest factor typ. 1.78 (400 V AC)
typ. 2.1 (480 V AC)
Rise time < 80 ms (UOut = 10 % ... 90 %)
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Fuse protection (secondary side) electronic
thermal-magnetic
thermal
Signal
Signal ground SGnd Reference potential for Out1. Out2. and Rem
Signal Out 1 (configurable)
Digital 24 V DC 20 mA
Default 24 V DC 20 mA 24 V DC for UOut > 0.9 x USet
Signal Out 2 (configurable)
Digital 24 V DC 20 mA
Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
Default 24 V DC 20 mA 24 V DC for POut < PN
Signal relay 13/14 (configurable)
Default closed (Uout > 0.9 USet)
Digital 24 V DC 1 A
30 V AC/DC 0.5 A
Connection method Screw connection
Conductor cross-section, rigid min. 0.2 mm²
Conductor cross-section, rigid max. 6 mm²
Conductor cross-section flexible min. 0.2 mm²
Conductor cross-section flexible max. 4 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. 4 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. 4 mm²
Conductor cross-section AWG min. 24
Conductor cross-section AWG max. 10
Stripping length 8 mm
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Output
Connection method Screw connection
Conductor cross-section, rigid min. 0.2 mm²
Conductor cross-section, rigid max. 6 mm²
Conductor cross-section flexible min. 0.2 mm²
Conductor cross-section flexible max. 4 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. 4 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. 4 mm²
Conductor cross-section AWG min. 24
Conductor cross-section AWG max. 10
Stripping length 8 mm
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Signal
Connection method Push-in connection
Conductor cross-section, rigid min. 0.2 mm²
Conductor cross-section, rigid max. 1 mm²
Conductor cross-section flexible min. 0.2 mm²
Conductor cross-section flexible max. 1.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. 0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. 0.75 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. 0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. 1.5 mm²
Conductor cross-section AWG min. 24
Conductor cross-section AWG max. 16
Stripping length 8 mm
Types of signaling LED
Floating signal contact
Active signal output Out1 (digital, configurable)
Active signal output Out2 (analog, configurable)
Remote contact
Signal ground SGnd
Signal output
Signal option Output current
Output voltage
Output power
UIN input voltage OK
Operating hours
Early warning of high temperatures
OVP voltage limitation active
Phase monitoring
POut > 100 % (LED lights up yellow, output power > 480 W)
> 75 % (LED lights up green, output power > 360 W)
> 50 % (LED lights up green, output power > 240 W)
UOut > 0.9 x USet (LED lights up green)
< 0.9 x USet (LED flashes green)
Item number 2904622
Packing unit 1 pc
Minimum order quantity 1 pc
Sales key CM10
Product key CMPI33
GTIN 4046356986885
Weight per piece (including packing) 1.562 g
Weight per piece (excluding packing) 1.203 g
Customs tariff number 85044095
Country of origin TH
| Motorola | MVME2100 |
| MOTOROLA | MVME172-533 |
| MOTOROLA | MVME715P |
| MOTOROLA | MVME712A/AM |
| MOTOROLA | MVME705B |
| MOTOROLA | MVME147SRF |
| MOTOROLA | MVME335 |
| MOTOROLA | MVME333-2 |
| MOTOROLA | FLN4234A |
| MOTOROLA | VME172PA-652SE |
| MOTOROLA | 01-W3324F |
| MOTOROLA | BOARD 466023 |
| MOTOROLA | MVME162-223 |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|