DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
Honeywell  TDC‑3000 BASIC,LEPIU Low‑Energy PIU,4DP7APCFA309
❤ Add to collection

Honeywell TDC‑3000 BASIC,LEPIU Low‑Energy PIU,4DP7APCFA309

Honeywell  TDC‑3000 BASIC,LEPIU Low‑Energy PIU,4DP7APCFA309

11620.00
¥9950.00
¥9950.00
¥9950.00
Weight:2.000KG
Description

Honeywell  TDC‑3000 BASIC,LEPIU Low‑Energy PIU,4DP7APCFA309






TDC‑3000 BASIC,LEPIU Low‑Energy PIU,4DP7APCFA309

The optional Touchscreen and Trackball are not to be used together on the same US, so

they share the same connector (J1) on the EPDGP I/O card.  When the Trackball or

Touchscreen is selected are bulkhead connected at the transition panel (see Figure 2-7).

1. The cables from the optional touchscreen pass through the clamps in the left location

marked TOUCHSCREEN on the lower transition panel in Figure 2-5. and are to be

connected to the EPDGP I/O card in slot 2 as shown in Figure 2-6.

2. Plug the large connector into J1. marked TOUCHSCREEN or TRACKBALL in Figure

2-6.  on the EPDGP I/O card and the small connector into J4. marked POWER in

Figure 2-6.  The EPDGP I/O card may have to be partially or completely pulled out to

make these connections.  Use proper board handling precautions, including a grounded

wrist-strap, to extract the card.  Use care not to disturb or dislodge existing cables and

then firmly reseat the card.

3. Using a cable-tie (51190879-001) on each cable, fasten the cables to their strain-relief

clamps on the upper transition panel.

WagoI/O-IPC 758-873
CONVERTEAMMVS3000-4001
GEMX150
GEIS215ACLEH1A
GEIS200ERIOH1A
ABB1VCF752000
YASKAWAEUA615100
Kollmorgen6SM37VL-6000
BENTLY NEVADA3500/22M-01-01-00 138607-01+140734-01
BENTLY NEVADA3500/40-01-00 (140734-01+125680-01)
BENTLY NEVADA330180-51-00
BENTLY NEVADA3500/50-01-00 133388-02+ 133442-01
BENTLY NEVADA3500/22М-01-01-00 (138607-01 + 288055-01)
BENTLY NEVADA3500/42М-02-00 ( 176449-02 + 128240-01)
BENTLY NEVADA3500/05-01-01-00
BENTLY NEVADA330500-02-02
BENTLY NEVADA3500/62-05-00 (163179-03+ 136294-01)
BENTLY NEVADA3500/25-01-03-00 (149369-01+ 135473-01)
FOXBOROP0916FJ
FOXBOROP0914XS
FOXBOROP0926GW
FOXBOROP0926GU

2.7.11 Trackball Cabling

The cable from the optional trackball is to be connected to the lower transition panel at the

left location marked Trackball in Figure 2-5.  Use a small screwdriver to tighten the screws

(2) on the connector.  In accordance with the user’s preference, place the trackball either to

the right or left side of the keyboard

If your Enhanced Micro TDC3000 System has one color monitor and no options except a

touchscreen or trackball, there is no further cabling to be done on tower #2.  Skip this

section and proceed with subsection 2.10. Installation Wrap-Up.

If you have a second Universal Station or additional options, consult the paragraphs in this

section that deal specifically with those options and cable them accordingly.

The following subsections, where applicable, may contain information on the EMC

Directive that affects the hardware.  When applicable, the EMC hardware information will

usually follow the hardware that is not in compliance with the directive.

2.8.1  Optional Universal Station Upgrade

Adding this kit upgrades a basic Enhanced Micro TDC3000 System.  This involves

adding a Universal Station node containing K2LCN, EPDG2. EPDGC I/O boards, and

keyboard.  The monitor is ordered separatly.  Refer to MX-MTUS34 or MX-MTUS36

Upgrade Kit Installation Instructions for directions for upgrade.

2.8.2  Optional Redundant Network Interface Module

The redundant NIM, in conjunction with a redundantly-connected Advanced Process

Manager, provides a level of protection in case of equipment failure

Ref. #

Cabling for the Universal Station is shown in the following figure and table.

Application Notes

51192126-200 Video Cable

51308099-100 Mouse/Trackball Interface Cable

Not Applicable

51308103-003 Printer Cable – 3 meters/9.8 ft.

51308103-008 Printer Cable – 8 meters/26.3 ft.

51308103-015 Printer Cable — 15 meters/49.2 ft.

51192054-101 Cable,SCSI Shielded, 50 position

51305070-200 Cable, SCSI

51308110-100 Cartridge DC Power Cable

51308109-100 Cartridge DC Power Cable (in Enclosure)

51308105-200 Keyboard Interface Cable

51308104-100 Keyboard Interface Cable (in Keyboard Tray)

51304496-046 Engineer"s Keyboard Cable (in Keyboard Tray)



  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines