B&R ECCP70-01 MULTI CPU type B 42 KByte SRAM
B&R ECE161-0 MULTI digital input module
Material number:
ECE161-0
Description:
MULTI digital input module 16 inputs 24 VDC/VAC 0->1: 10 msec, 1->0: 20 msec Sink/source
RemoteI/O allows remote I/O modules to be connected to the CPU over long distances. A bus
cable is used to connect the Remote Master Module and up to 31Remote Slaves. A new I/O
bus which can address a maximum of13modules begins with every slave
Note the following:
• The remote master is a system module and must therefore be situated on the main base
plate.
• The remote slave is in a power supply module on the expansion backplane.
• The slave address is set with a node number switch on the remote slave. This number is
then used for addressing a remote I/O bus
Bus Cable (according to DIN19245. Part3)
The remote master and slave modules are connected using two twisted pair cables which must
conform to the following specifications.
The twisted pair cable must be terminated on both ends with a terminating resistor.
Figure 26: Wiring remote master and slave modules
Specifications
Wave Impedance 135 - 165 Ω (3 - 20 MHz)
Distributed Capacitance <30 pF / m
Loop Resistance <110 Ω/ km
Wire Diameter > 0.64 mm
Wire Cross Section > 0.34 mm
The remote bus is fitted with terminating resistors at both ends. Terminating resistors are
integrated in all B&R remote bus connectors 0G1000.00-090. The terminating resistors can be
turned on or off
The cabling described for the remote I/O bus (bus cable, terminating resistors) is also used for
PROFIBUS. The PROFIBUS network modules available from B&R are NW150 for the B&R
SYSTEM 2005 and NW100 for the B&R SYSTEM 2010.
2.1.5 RS485 Network
The cabling described for the remote I/O bus (bus cable, terminating resistors) is also used for
an RS485 network
2.2 Configuring a Mixed System
2.2.1 Bus Expansion
An expansion slave of a 2010 or 2005 system can be coupled to an expansion master of the
other system. The following restrictions must be noted:
2005 to 2010
Expansion slaves from 2005 expansion backplanes can be connected directly to a 2010
expansion master (maximum 4 per 2010 system). For this type of expansion, both interfaces of
the 2010 expansion master can be used. Only the following configurations are permitted.
Depending on the chosen configuration, the expansion backplane number must be addressed
in the programming system with the following numbers
B&R 2010 I/O modules can be connected to a 2005 expansion master with an expansion slave
(which has a power supply module inserted into the expansion slot), or to a 2005 expansion
slave (Expansion Slave OUT).
The module address of the 2010 expansion slave is set with a node number switch, from where
the 2010 I/O module addresses begin. Settings are made in steps of ten (00. 10. ...,90). A
maximum of 20I/O modules can be installed on one of these bus segments. However, it is
possible to use up to 99modules with a 2010 expansion master.
2.2.2 RemoteI/O Bus
A remote master (B&R SYSTEM 2005. B&R SYSTEM 2010 or B&R SYSTEM 2000 Logic
Scanner) can be connected with up to 31remote slaves. It is also possible to mix the B&R 2003.
B&R 2005 and B&R 2010 systems.
Each remote slave starts a new I/O bus. The maximum number of slots available depends on
the type of slave
2.3.1 CAN Bus Features
• Low costs
• High noise immunity through differential signals
• Bus structure
• Open system
• Fast data transfer for small data packages (up to 8 bytes)
• Error detection by means of CRC (Cyclic Redundancy Check) and frame testing ->
hamming distance 6
• Predictable transmission time for highpriority messages (real-time behavior)
• Easy to use
2.3.2 Bus Length and Cable Type
The type of cable used depends largely on the required bus length and the number of nodes.
The bus length is mainly determined by the bit rate.
The following bus lengths are permitted with a maximum oscillator tolerance of 0.121%
Relationship between the number of nodes and bus length for certain cable types using B&R
default settings:
| SDI-1624 CCV1.1 high-performance secure digital input module |
| SDO-0824 CCV1.3 high-performance digital output module |
| USI-0002 Universal Safety Interface module (USI) |
| QPP-0001 high-performance digital input module |
| IC800SSI216RD2-CE VersaMotion series servo motor controller |
| SSA-G1018-0652 high-performance Gigabit Ethernet switch |
| 9907-1200 electro-hydraulic converter |
| ICP232.2-5V 029.361114 Industrial grade isolated RS-232 transceiver |
| IC800SSI228RD2-CE Digital Genius I/O series servo motors |
| VP32502X 75X-6025-25 151-0025 industrial-grade single-board computer (SBC) |
| PPD117A3011 3BHE030410R3011 exciting controller |
| PFTL201D 100KN 3BSE008922R0100 high-precision force measurement device |
| TRICON 3604E digital output module |
| PR6423/002-030-CN+CON021 high-performance eddy current sensor |
| SDV144-S63 16-channel 24V DC digital input module |
| CI873AK01 high-performance communication interface module |
| CI867AK01 interface module |
| CI854BK01 Profibus communication interface suite |
| BC810K02 CEX-bus interconnect unit |
| DPG-2201-001 digital controller |
| LSU-112DG load sharing and protection controller |
| LUS-122DG variable load distribution unit |
| 6181P-17A2SW71AC AC-powered VersaView Plus Series F Integrated Display Industrial Computer |
| ARND-3120B23 expansion terminal board |