DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
Honeywell  TDC‑3000 NIM Network Interface Module,51304481‑200
❤ Add to collection

Honeywell TDC‑3000 NIM Network Interface Module,51304481‑200

Honeywell  TDC‑3000 NIM Network Interface Module,51304481‑200

14520.00
¥8610.00
¥8610.00
¥8610.00
Weight:2.000KG
Description

Honeywell  TDC‑3000 NIM Network Interface Module,51304481‑200






TDC‑3000 NIM Network Interface Module,51304481‑200

Check to see that all signal cables and coaxial cables entering towers are properly

secured to the rear of the towers by strain-relief clamps or connector screws.  Install the

rear covers with star washers on both towers.

2. If you have not already done so, dress signal and power cables neatly, at the rear of the

system, so that they will not be a personnel hazard.  Dress cables that leave the area to

connect to UCN taps, etc., so they will not be stepped-on or damaged in any way.

3. Gather packing material, boxes, and pallets and remove them from the operations room.

Temporarily store the shipping boxes in the event something must be returned to the

factory.

4. Clean and tidy the operations room to keep operating media (cartridge disks) from

being unduly exposed to dust and foreign material.

5. Check each cartridge slot of the cartridge drives.  If there are polystyrene shipping

inserts in the slots, carefully remove them.

6. Make sure the power switches on both towers, the color monitor(s), and the printer are

all OFF.

西门子6ES7326-2BF10-0AB0
西门子6ES7331-7TF01-0AB0
西门子6ES7331-7TB00-0AB0-
西门子6GK1503-3CC00
ABB70EA04b – E HESG492059
GEIS230JPDGH1B


GEDS3800HPRB1D1C
GEDS200DCFBG1ALC
UniOPeTOP40B-0050
ABBPM866AK02 3BSE081637R1
SARTORIUSMDB-8E
ROLLS-ROYCESLIO 02
Bently Nevada3500/22M-01-01-01
AlstomUT150-2
EMERSONPR6423 009-041+CON 041/913-030
HoneywellHCIX15-TE-FA-NC
KEBAD3-DU 360/A-2100-20
SARTORIUSMDB-8E

7. Plug power cords from all units into the proper receptacles for the power required.

8. Continue on to Section 3 for power-up tests and other checkout procedures

3.1  POWER-ON TESTS

Do not perform any of these tests until the Enhanced Micro TDC3000 Control System has

been installed according to Section 2.  Check that the rear panels on the towers have been

installed and all signal cables and power cords connected.  See that the area is cleared of

packing material and other installation debris, and the area is clean.  Check that all power

switches are off.

You will now perform a series of checks and tests to insure the equipment is working.  If

any of the tests are not met, refer to Section 6. Service.

3.1.1  Tower #1 Electronics Checks

Tower #1 is the tower on the right with two black cartridge drives in the upper left corner.

1. Use both hands to remove the front panel from tower #1 by grasping the edges of the

panel near the bottom and pulling the panel straight out.  Spring-loaded catches on each

side of the panel disengage, and the panel may be removed by pulling it out and down.

Be careful not to damage the cartridge drives when removing the panels

You now have access to the front of the Multinode Module in tower #1.  Locate the

power switch (see Figure 3-1).  Before turning power on, ensure the LO-NOM-HI

jumper just below and to the right of the power switch is set in the NOM or center

position.  This is a maintenance jumper that is not to be changed by the user.

3. Compare your module with the Figure 3-1 illustration.  Note the module contains four

nodes and each node has a processor board in the first board slot and a personality or

peripheral board in the second slot.  Nodes have unique numbers from 1 to 8 (not A,

B, C, D as in the figure) and are factory set.  You will identify the node numbers in an

upcoming test.  Other board slots may or may-not contain boards, therefore, are shown

shaded.  Note a horizontal row of green LEDs along the bottom, with another row of

either yellow or green LEDs just above them.  Note each processor board contains a

display containing several red LEDs and a red alphanumeric status display


  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines