Vibro-Meter Relay expansion RLC16 Mk2 600-045L
Relay expansion RLC16 Mk2 600-045L
As a rack controller for a VM600Mk2 monitoring
system, the CPUMMk2 module can manage the
configuration of XMx16 + XIO16T modules that are
operating without a VibroSight Server.
(Note: MPC4Mk2 + IOC4Mk2 modules are configured
using the VibroSight ® software.) The ALARM RESET
button on the front panel of the CPUMMk2 module
can be used to clear the alarms latched by the
monitoring modules (MPC4Mk2) in the rack. This is a
rack-wide equivalent of resetting alarms individually
for each module using discrete signal interface alarm
reset (AR) inputs or VibroSight ® software
commands.
A security key lock, with a removable key, on the front
panel of the CPUMMk2 module can be used to enable
VM600Mk2 rack (CPUMMk2) security.
DESCRIPTION (continued)
LEDs on the front panel of the CPUMMk2 module
(front of VM600Mk2 rack) indicate the mode of
operation and status of the CPUMMk2 + IOCNMk2
module, and the status of its system Ethernet and
fieldbus communications.
IOCNMk2 module
The IOCNMk2 module acts as a signal and
communications interface for the CPUMMk2 module.
It also protects all inputs against electromagnetic
interference (EMI) and signal surges to meet
electromagnetic compatibility (EMC) standards.
LEDs on the front panel of the IOCNMk2 module (rear
of VM600Mk2 rack) indicate the status of its system
Ethernet and fieldbus communications.
Fieldbus communications
| GE | DS200SNPAH1AB |
| GE | DS3800NHVL |
| GE | DS200FCGDH1ABA |
| GE | UR-9WH |
| GE | XD1-G11 |
| WOODWARD | 8440-1935 |
| WOODWARD | TG-13 |
| KEBA | T155-WL |
| GE | MIB30HICE00000 |
| GE | P7650B0C0B6E0A0A |
| triconex | 3723X |
| triconex | 3506X |
| triconex | 3626X |
| ABB | REF615 HBFEAEAGNCA1BNA11G |
| ABB | SYN5302A 3BHB006716R0277 |
| Vibro-meter | VM600-RLC16 |
| Vibro-meter | VM600-IOC N |
| Vibro-meter | VM600-RPS-6U |
| Vibro-meter | VM600-CPU M |
| GE | IS220UCSAH1A / IS220UCSAH1A |
| GE | IS200TDBTH2A |
| GE | IS200TDBSH6A |
| GE | IS200WROBH1A |
The CPUMMk2 + IOCNMk2 module has two fieldbus
interfaces (ports), FIELDBUS1 and FIELDBUS2.
available on the IOCNMk2 module (rear of VM600Mk2
rack).
The fieldbus ports allow the CPUMMk2 module to act
as a data communications gateway between a
VM600Mk2 rack and external devices that use
fieldbus networks. In order to do this, the CPUMMk2
acts as a fieldbus server (slave) device that obtains
data from the modules in the VM600Mk2 rack
(MPC4Mk2 and XMx16 modules, and the CPUMMk2
module itself) to share with fieldbus client (master)
devices such as a DCS or PLC via one of the
CPUMMk2 + IOCNMk2 module’s fieldbus interfaces:
Modbus TCP and/or PROFIBUS DP.
Each fieldbus port, FIELDBUS1 and FIELDBUS2.
consists of two connectors, one for serial-based
fieldbus standards and one for Ethernet-based. Both
fieldbus ports can be active at the same time but only
one connector can be used per interface/port
(that is, connector J1 or J2 for FIELDBUS1. and
connector J4 or J5 for FIELDBUS2).