easYgen-3500XT-P2-K58 8440-2318
❤ Add to collection

easYgen-3500XT-P2-K58 8440-2318

easYgen-3500XT-P2-K58 8440-2318

52660.00
¥51440.00
¥51440.00
¥51440.00
Weight:2.000KG
Description

easYgen-3500XT-P2-K58 8440-2318


External breaker logic is enabled via configuration of parameter

3411 Ä p. 217 to "EXTERNAL".

All breaker control (especially the CB closing instructions) must be

carried out via master controller (e.g. a PLC).

The easYgen controller always issues additionally the breaker

open command under fault conditions and in the breaker unloading

states (Unloading GCB) if the stop request is active.

STOP MANUAL AUTOMATIC

The GCB is opened; the MCB is operated

depending on the setting of "Enable MCB"

(parameter 12923 Ä p. 228/Ä p. 907).

Mains parallel operation can be initiated by

pressing the "GCB On" or "MCB On" push

button.

The GCB is synchronized via an add-on

request and a mains parallel operation is

performed. When a shed-off request is

issued, the generator sheds load and

opens the GCB and the engine is shut

down following the configured cool down

period.

Emergency power: The emergency power

operation is terminated following the expi

ration of the mains settling time. The MCB

is synchronized and closed, putting the

system back into a mains parallel opera

tion.

OPEN TRANSIT.: Breaker logic "Open transition / change-over / brake-before-make"

The MCB and GCB are never synchronized in this breaker logic mode.

The GCB is opened; the MCB is operated

depending on the setting of "Enable MCB"

(parameter 12923 Ä p. 228/Ä p. 907).

A change can be made to either generator

or mains operation by pressing either the

"GCB On" or "MCB On" push-button. The

"STOP" push-button opens the GCB and

simultaneously stops the engine.

A change is made to generator operation

through an add-on request. Once the add

on request is terminated, the system

changes back to mains operation. The

MCB is closed when the busbar is dead,

even if there has not been an add-on

request. Emergency power operations are

terminated following the expiration of the

mains settling timer. The GCB opens and

the MCB closes, transferring all loads to

the mains.

CLOSED TRANSIT.: Breaker logic "Closed transition / make-before-brake / overlap synchronization"

The MCB and the GCB are synchronized, in order to avoid a dead busbar in this breaker logic mode. Immediately after the synchroni

zation of one breaker, the other is opened. Continuous mains parallel operation is not possible.

The GCB is opened; the MCB is operated

depending on the setting of "Enable MCB"

(parameter 12923 Ä p. 228/Ä p. 907).

Synchronization of either the generator or

the mains can be initiated by pressing the

"GCB On" or "MCB On" push-button.

The GCB is synchronized via an add-on

request. After the GCB closes the MCB is

opened. Following the shed-off request

being issued, the MCB is synchronized

and closed. After the MCB has closed the

GCB is opened.

Emergency power: The emergency power

operation is terminated following the expi

ration of the mains settling time and the

MCB synchronizing to the generator. The

MCB closes and the GCB opens immedi

ately afterwards.

INTERCHANGE: Breaker logic "Soft loading / interchange synchronization"

The MCB and the GCB are synchronized, in order to avoid a dead busbar in this breaker logic mode. The operation of a breaker

under load is avoided by utilizing the ability to soft load. Continuous mains parallel operation is not possible with this breaker logic.

Following the shed-off request, the MCB synchronizes and closes, the generator soft unloads to the mains and the GCB opens. After

the GCB is open the engine is stopped following the expiration of the configured cool down period.

The GCB is opened; the MCB is operated

depending on the setting of "Enable MCB"

(parameter 12923 Ä p. 228/Ä p. 907).

Synchronization of either the generator or

the mains can be initiated by pressing the

"GCB On" or "MCB On" push-button.

Via an engine request, the GCB is

ABBPFCL201C 20KN   3BSE023409R20
ABBPFCL201CE   10KN 3BSX105983-100
ABB3BHE046836R0102   GFD563A102
ABBPVD164A2059   3BHE014340R2059
ABBUNS4684A-P,V.1   HIEE305114R00R0001
ABBPFRL101C-1.0KN   3BSE023316R1002
ABBSUE3000  1VCF750090R0804
ABBDSAO110   57120001-AT/1
ABBDSAO120   57120001-EY
ABBREF542
ABB 7625013-S
ABB500TTM02   1MB150021R01161HF930712X010
ABB500CMP04   HE401314/0001 1MRB150051R1
ABB500CSP04   HE401314/0002 1MRB150051R2
ABB500PB101   1MRB178009R0001 1MRB200064/C
ABB500CPU03   1HDF700003R5122
ABB500TRM02   1MRB150011R0001
ABB500TRM02   1MRB150011R1
ABB500SCM01   1MRB150004R0001 1MRB200059/C
ABB500SCM01   1MRE450004R1

synchronized and the generator power is

increased. The MCB is then opened. Fol

lowing the disabling of the engine request,

the MCB is reverse synchronized and the

GCB is then opened.

Emergency power: The emergency power

operation is terminated following the expi

ration of the mains settling time. The MCB

closes, the load is transferred, and the

GCB opens.

STOP MANUAL AUTOMATIC

PARALLEL: Breaker logic "Mains parallel"

This operation mode may be used both in the case of an islanded system, an islanded parallel system, and a system that is operated

in mains parallel.

The GCB is opened. Mains parallel operation can be performed

via the "GCB On" push-button.

The GCB is synchronized via an add-on

request and mains parallel operation is

performed.

When a shed-off request is issued, the

generator sheds load, the GCB is opened,

and the engine is shut down following the

configured cool down period

STOP MANUAL AUTOMATIC

PARALLEL: Breaker logic "Mains parallel"

This operation mode may be used both in the case of an islanded system, an islanded parallel system, and a system that is operated

in mains parallel.

The GCB is opened. Mains parallel operation can be performed

via the "GCB On" push-button.

The GCB is synchronized via an add-on


  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines