HIMA HIMatrix ELOP II 892042336 Version V5.6 Build 1501.9810 IV1
HIMA ELOP II (Part Number: 892042336), specifically Version V5.6 Build 1501.9810 IV1.
is the legacy professional engineering software suite used for the configuration, programming, and diagnosis of HIMA safety-related automation systems.
While modern HIMA systems primarily use SILworX, ELOP II remains the critical standard for maintaining and managing the vast global install base of HIMatrix and HIQuad controllers.
Technical Parameter Table
| Parameter | Specification |
| Model / Part Number | 892042336 (ELOP II Professional) |
| Software Version | V5.6 (Build 1501.9810 IV1) |
| License Type | Full Package / Professional (Hardware USB Dongle) |
| Programming Languages | IEC 61131-3 (FBD, SFC, LD, ST) |
| Controller Support | HIMatrix F-Series, HIQuad (H41q, H51q), HIMax (Limited) |
| Safety Integrity Level | Certified for SIL 3 (IEC 61508) |
| Operating System | Windows 7, Windows 10 (compatibility mode recommended) |
| Min. System Req. | 256 MB RAM (Project size dependent) |
| Interface Support | Ethernet (TCP/IP), RS-485, Profibus-DP, Modbus |
Safety Logic Simulation: Includes a robust offline simulation environment that allows engineers to verify safety logic before deploying to live hardware, significantly reducing commissioning risk.
Force & Monitoring Tools: Provides real-time online monitoring of I/O states and internal variables, with secure signal forcing capabilities for testing and maintenance.
Redundancy Management: Specialized tools for configuring high-availability architectures, ensuring seamless switchover in redundant safety systems.
Object-Oriented Configuration: Allows for the reuse of certified function blocks, ensuring consistency and faster validation across large-scale projects.
Built-in Diagnostics: Detailed error reporting and system event logging help identify hardware faults or communication bottlenecks instantly.
Application Cases
Refinery Maintenance: Used by plant engineers to modify or troubleshoot existing H41q/H51q safety systems during turnarounds.
Burner Management (BMS): Configuring complex safety sequences for boilers and furnaces requiring SIL 3 compliance.
High-Pressure Protection (HIPPS): Programming high-speed logic for pipeline overpressure protection.
Legacy Upgrades: Serving as the bridge for plants transitioning from older ELOP versions to modern SILworX-ready architectures.
Installation and Maintenance
Installation
Hardware Key: The installation requires the physical USB Hardlock (Dongle) included in the package. Without this, the software will run in "Demo" mode only.
Driver Setup: Install the Hardlock drivers before plugging in the USB key to avoid recognition errors.
Project Path: It is recommended to install on a local disk rather than a network drive to ensure deterministic performance during controller communication.
Maintenance
Backup Strategy: Regularly export projects as .ZED (compressed) files.
Service Packs: Ensure the specific Build (1501.9810) is matched across all engineering workstations to avoid project synchronization issues.
OS Compatibility: If running on modern hardware, ensure "Run as Administrator" is enabled to allow the software to access communication ports.
Other Models in the Same Series
ELOP II Factory: A specialized variant often used for HIMatrix compact systems.
SILworX: The successor to ELOP II, used for all new HIMA hardware generations.
892042300: ELOP II Standard license (limited functionality compared to Professional).
892042420: OPC Server for ELOP II (for SCADA integration).
Unique Product Description
The ELOP II 892042336 V5.6 is the "Gold Standard" for safety engineers managing veteran HIMA systems.
Its stability and precision have made it the backbone of functional safety in the process industry for decades.
Unlike standard PLC software, ELOP II enforces strict safety-oriented workflows that prevent accidental changes to safety logic, ensuring the plant remains protected at all times.
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|