Vibro-Meter ABE044 - 6U 19-inch rack (with expansion slots)
❤ Add to collection

Vibro-Meter ABE044 - 6U 19-inch rack (with expansion slots)

Vibro-Meter ABE044 - 6U 19-inch rack (with expansion slots)

¥5690.00
¥4560.00
¥4560.00
¥4560.00
Weight:2.000KG
Description

Vibro-Meter ABE044 - 6U 19-inch rack (with expansion slots)






ABE044 - 6U 19-inch rack (with expansion slots)

Channel inhibit function

The channel inhibit function allows individual AMC8 channels to be temporarily bypassed,

that is, it temporarily inhibits the protection offered by any associated relays.

The channel inhibit function is intended to allow a component in a measurement system

front-end, such as a sensor/transducer or signal conditioner, to be replaced for an individual

channel while the other machinery monitoring channels and functions continue to operate as

normal.

This allows the machinery being monitored to continue to operate (if the protection offered by

the other machinery monitoring channels and functions is adequate). It also allows any

control system using the relays to avoid false trips during such maintenance activity.

When the channel inhibit function is activated for an AMC8 channel:

• The channel continues its processing as per its configuration but inhibits the protection

offered by any associated relays.

This allows the effect of any changes to the measurement system front-end to be

observed. In this way, it can also be ensured that there are no ongoing alarm conditions

before the de-activation of the channel inhibit.

• Any DCoutput functionality associated with the channel continues, if enabled.

• The following flags (bits) for the channel processing are forced to a known state:

• The error bit (Err), OK system check (SOK), alarm (A+, A−) and danger (D+, D−)

flags are all forced to a normal state (which is false, that is =0).

The sensor bypassed (SBP) flag and the global channel OK fail flags are also set

active.

ABB3BHE057901R0101 PCD235C101
Triconex3704E
Triconex3504E
Triconex3504E
EMERSON1X00781H01L
EMERSONPR6423 009-041+CON 041/913-030
KONSGBERGRCU500
KONSGBERGRMP400
KONSGBERGRDIOR400
Cutler Hammer1775K PMPP1700
MOORE INDUSTRIESMDS/PRG/10-30DC/-MAO
ABBDHH805-A
WagoI/O-IPC 758-873
CONVERTEAMMVS3000-4001
GEMX150
GEIS215ACLEH1A
GEIS200ERIOH1A

NOTE: The VM600 MPS1 and VM600 MPS2 software packages use the SBP (sensor

bypassed) flag to refer to the channel inhibit function.

• Any processing channels that depend on the channel are automatically bypassed.

• The channel’s status indicator (LED) on the panel of the AMC8 card slowly blinks green

for the duration of the channel inhibit (approximately once per second).

When the channel inhibit function is de-activated for an AMC8 channel, the card:

• Waits 12seconds for signal stabilisation (total recovery time).

• Resets (clears) any latched alarms.

• Stops forcing the flags for the channel processing to a normal state, so that the true

status of the machinery monitoring system is returned again. The sensor bypassed

(SBP) flag is also set inactive

1OK system checking

The OK System monitors the input signal from the sensor in order to verify if the sensor is

connected and operating normally. To do this, the DC signal level is compared against two

user-configurable OK levels: a minimum normal level and a maximum normal level.

Any problem with the transducer and/or signal conditioner or connecting cable that causes

the signal to deviate beyond these OK levels will cause an individual alarm for the input

channel (corresponding to the individual GlobalChannelOK bit).

As shown in Figure5-5:

• The “confirmation time” is a fixed firmware time delay used so that only an input signal

that is outside the configured OK levels for a time period greater than 250 ms is detected

as an OK system failure. This is used to ensure that noise (“spikes”) on the DC signal

level are not accidentally recognised as failures.

• The “response time” is the maximum time delay from the time that an OK system failure

is detected until the corresponding alarms are set (GlobalChannelOK bit for the input

channel). The actual time delay depends on the processor load of the card but is less

than 100ms.


  • SAUTER AXT 201. 211: Thermal actuator for unit valves with stroke
  • SAUTER AXS 215S: Continuous actuator for unit valves, with stroke
  • SAUTER AXM 217S: Motorised actuator for unit valves with positioner
  • SAUTER AVM 321S, 322S: Valve actuator
  • SAUTER AVM234S: SUT valve actuator with positioner
  • SAUTER AVM 105. 115: Valve actuator
  • SAUTER AVF 234S: SUT valve actuator with spring return
  • SAUTER AVF124: Actuator with spring return
  • SAUTER AKM115SAF332: Smart Actuator for ball valve, BACnet/IP
  • SAUTER AKM115SA: Smart Actuator for ball valve
  • AKM 105S, 115S: Rotary actuator with SAUTER Universal
  • SAUTER AKM 105. 115: Rotary actuator for ball valve
  • SAUTER AVM 234S: SUT valve actuator with positioner
  • SELSEL-T401L Ultra-High-Speed Line Relay
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-787 Transformer Protection Relay
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL-487E Transformer Protection Relay
  • SEL-400G Advanced Generator Protection System
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700BT Motor Bus Transfer Relay
  • CTI 2500 Series® Slice Ethernet Remote I/O System
  • CTI 2500 Series® Compact Programmable Automation Control System
  • CTI 2500 Series® Classic Programmable Automation Control System
  • CTI 2500 Series® Bases
  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • EATON Instructions for the FP-5000
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671