DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
Vibro-Meter  ABE056 - 1U ultra-thin single-rack
❤ Add to collection

Vibro-Meter ABE056 - 1U ultra-thin single-rack

Vibro-Meter  ABE056 - 1U ultra-thin single-rack

9680.00
¥8580.00
¥8580.00
¥8580.00
Weight:2.000KG
Description

Vibro-Meter  ABE056 - 1U ultra-thin single-rack






ABE056 - 1U ultra-thin single-rack

Different versions of the CPUM card

In 2015. the CPUM card was updated to use a new PC/104 CPU module (PFM-541I or

equivalent) that supports two Ethernet interfaces by default, which required updates to the

underlying carrier board (that is, the CPUM card itself).

Previously, the CPUM card was fitted with a CPU module (MSM586SEN or equivalent) that

supported one Ethernet interface by default and required an additional Ethernet controller

module (MSME104 or equivalent) to be fitted in order to be Ethernet redundant.

So the different versions of the CPUM card in use are:

• Later versions of the CPUM card (PNR 200-595-076-HHh or later) fitted with

the PFM-541I or equivalent CPU module (see Figure6-1).

• Earlier versions of the CPUM card (PNR 200-595-075-HHh or earlier) fitted with

the MSM586EN or equivalent CPU module (see Figure6-3).

NOTE: Due to changes to the underlying CPUM card (carrier board), the later versions of

the CPUM card are not compatible with the earlier versions of the CPUM card.

Accordingly, the PFM-541I or equivalent CPU module can only be used with the

later versions of the CPUM card (PNR 200-595-076-HHh or later) and the

MSM586EN or equivalent CPU module can only be used with the earlier versions

of the CPUM card (PNR 200-595-075-HHh or earlier).

6.2General overview

The CPUM card is a modular CPU (central processing unit) card that acts as “rack controller”

in a networked VM600 system. Depending on system requirements, the CPUM can be used

either alone in the rack (installed in the front card cage) or in conjunction with the associated

IOCN input/output card (installed in slot0 of the rear card cage, directly behind the CPUM).

The CPUM card consists of a carrier board with two PC/104 type slots that can accept

different PC/104 modules, typically a CPU module in PC/104 slot1 and an optional serial

communications module in PC/104 slot2.

All CPUM cards are fitted with a CPU module (PC/104 slot1) that supports two Ethernet

connections (primary and secondary) and two serial connections (primary and secondary).

That is, both the Ethernet redundant (PNR200-595-0Ss-33h) and serial redundant

(PNR200-595-0Ss-53h) versions of the CPUM card.

The CPUM card with the CPU module provides:

• Primary Ethernet communications via the ‘NET’ connector (8P8C (RJ45)) on the CPUM

card’s panel or the ‘1’ connector (8P8C (RJ45)) on the IOCN card’s panel, if used.

NOTE: The ‘NET’ connector on the CPUM card and the ‘1’ connector on the IOCN

card are mutually exclusive, that is, only one can be used at any one time

(configured using jumpers on the CPUM).

• Secondary Ethernet communications via the ‘2’ connector (8P8C (RJ45)) on the IOCN

card’s panel, if used.

• Primary RS-232 communications via the ‘RS232’ connector (D-sub (DE-09)) on the

CPUM card’s panel.

• Secondary RS-232 or RS-485 communications via the ‘RS’ connector (6P6C

(RJ12/RJ25)) on the IOCN card’s panel, if used

The CPUM card can also be fitted with an optional serial communications module (PC/104

slot2) in order to support additional/redundant serial connections. This is, the serial

redundant version of the card (PNR200-595-0Ss-53h).

The CPUM card with the additional/redundant serial communications module provides:

• RS-485 (115.2kbps) communications as either half-duplex (2-wire) or

full-duplex(4-wire) via the ‘A’ and ‘B’ connectors (6P6C (RJ12/RJ25)) on the IOCN

card’s panel.

NOTE: The additional ‘A’ and ‘B’ serial connections can be used to configure multi-drop

RS-485 networks of VM600 racks using ModbusRTU communications.

A diagnostic LED (named DIAG) on the panel of the CPUM indicates the CPUM card status,

such as normal operation and whether VM600 MPS rack (CPUM) security is being used. The

CPUM card’s panel also contains an LCD display for showing the level of a selected

monitored output in bar-graph and digital form. The Alert and Danger levels are also indicated

on the bar graph.

Coloured LEDs (named OK, A and D) on the panel of the CPUM indicate the OK, Alert and

Danger status for the signal selected for display (see Figure2-12). If slot0 is selected, these

LEDs will indicate the general rack status.

SLOT and OUT (output) keys on the panel are used to select which signal to display. The

ALARM RESET button on the panel resets all latched alarms (and associated relays) for the

entire rack.

Possibilities allowed by the CPUM/ IOCN pair include:

• ‘One-shot’ configuration of all VM600 cards using a direct Ethernet or RS-232 serial

connection from an external computer (laptop, notebook, pen-computer, industrial

computer or flat-panel computer) running the VM600 MPSx software (MPS1 or MPS2),

from the Meggitt vibro-meter® product line.

• ‘One-shot’ configuration of all VM600 cards via Ethernet from a networked computer

running the VM600 MPSx software.

• Visualisation of signal levels and alarm limits using the display on the CPUM card’s

panel.

• External communication with third party devices such as a DCS or PLC.

ABBIMASI02
ABBIMASI03
ALSTOMV4559828-0001
GEP111-6052
ABB540CMD01
GEIS220PSVOH1A
GEIS220PDIOH1A
GEIS200BAPAH1A
EMERSON5X00419G02
ABB3AUA0000110430 BCU-12
BENDERIRDH275B435
GEIS230PCAAH1B
GEIS220PAICH1B
GEIS220YDOAS1A
GEA0005-4050-430
Rolls-royceR10I53S-MRP1TR01.5
HirschmannRS20-0800M4M4SDBEHH
HirschmannRS30-0802OOZZSDAEHH
HirschmannMS20-1600SABEHH
HirschmannMM20-T1T1T1T1SBHH
HirschmannMM20-Z6Z6Z6Z6SBHH
TRICONEX3721
TRICONEX3009
TRICONEX3009X



  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures