The Hirschmann BRS20-0600Z6Z6-STCZ99HHSES is a member of the advanced BOBCAT family of compact, managed Layer 2 Industrial Ethernet switches.

 Engineered to support the next generation of automation infrastructure, the BOBCAT platform bridges the gap between classic industrial applications and Time-Sensitive Networking (TSN) infrastructure.

Featuring an ultra-modern, robust design, this switch provides 6 ports in total: 4 Fast Ethernet RJ45 ports and 2 SFP transceiver slots supporting raw Fast Ethernet speeds.

 Operating on Hirschmann’s HiOS (Hirschmann Operating System), it delivers advanced redundancy, strict security baselines, and precise synchronization for real-time industrial applications.

Technical Table

Technical ParameterSpecification Value
Brand / ManufacturerHirschmann (A Belden Brand)
Model CodeBRS20-0600Z6Z6-STCZ99HHSES
Series DesignationBOBCAT Series (BRS)
Total Port Count6 Ports
Copper Ports4 x 10/100BASE-TX (RJ45 connectors)
Fiber/SFP Ports2 x 100BASE-FX (SFP fiber-optic transceiver slots)
Operating VoltageRedundant 12 VDC to 24 VDC inputs (Voltage range: 9.6 to 32 VDC)
Current ConsumptionMax. 380 mA at 24 VDC
Power ConsumptionMax. 9.1 W
Software LevelHiOS Layer 2 Standard (L2S)
Time SynchronizationIEEE 1588v2 PTP (Precision Time Protocol) hardware-supported
Housing Protection ClassIP30 rating (Metal/Polycarbonate composite)
Dimensions (W x H x D)57 mm x 140 mm x 140 mm
MountingStandard 35 mm DIN Rail mounting

Environmental Tolerance Conditions

Built to thrive inside crowded control panels subjected to thermal stress, the BRS20 is physically and electrically hardened:

Operating Temperature: 0°C to +60°C (Standard industrial rating)

Storage & Transport Temp: -40°C to +70°C

Relative Humidity: 1% to 95% (Non-condensing)

Conformal Coating: No (Standard bare assembly)

Mechanical Shock Resistance: IEC 60068-2-27 ($15text{ g}$ peak acceleration, $11text{ ms}$ pulse width).

Mechanical Vibration Tolerance: IEC 60068-2-6 ($3.5text{ mm}$ displacement at $2text{ to }9text{ Hz}$; $1text{g}$ acceleration up to $150text{ Hz}$).

EMC Immunity Standards: Certified to meet EN 61000-4 series requirements for high electrostatic discharge (ESD) immunity, surge, fast transients (bursts), and high-frequency conducted disturbances.

Operating Instructions

1. Initial IP Setup & Configuration

HiDiscovery Tool: Download the free Hirschmann HiDiscovery utility. Connect your commissioning laptop to the same network segment as the switch. 

The utility scans for the switch's hardware MAC address and lets you assign an IP address, subnet, and default gateway.

USB-C Console Interface: The front panel features a local USB-C port acting as an out-of-band serial console interface.

 Connect your PC via a USB-C cable and open a serial terminal emulator (9600 Baud, 8N1) to access the Command Line Interface (CLI).

Web-Based Graphical User Interface (HTML5): Navigate to the assigned IP address in a secure browser (HTTPS).

 Use the default setup wizard to configure passwords, change SNMP parameters, and establish security options.

2. Network Redundancy Setup

To establish high-reliability rings:

Navigate to Redundancy > MRP or HIPER-Ring in the web interface.

Select your designated backbone uplink ports (usually the SFP slots, ports 5 and 6).

Define the switch's role (Ring Manager or standard Client).

Activate the protocol before completing the physical loop to avoid packet storm issues.

Fault Diagnosis

The BRS20 offers comprehensive localized and network-level troubleshooting diagnostic signals:

Front Panel LED Diagnostics

Power Indicator (Power):

Green / On: Unit is receiving healthy voltage within the acceptable 9.6–32 VDC range on at least one input line.

Off: Loss of supply voltage.

Device Status (Status):

Green / On: Device is fully operational and healthy.

Red / Solid: A configured alarm event has triggered (such as link loss on a critical port or redundant power supply line failure).

Red / Flashing: Firmware update or self-test configuration failure.

ACA Active LED:

Green / On: External Auto-Configuration Adapter is detected and functioning.

Off: No ACA adapter connected.

Port-Specific Link/Activity (L/D):

Green / Solid: Physical hardware link is secure.

Green / Flashing: Port is transmitting/receiving Ethernet frames.

Dry Alarm Contact Relay

A physical terminal block on top contains a signaling contact. In normal operations, this dry contact relay remains closed.

If a critical error occurs (such as power failure to input line 1 or a monitored port link disconnect), the relay breaks open.

 Connect this to a PLC input to instantly alert the plant SCADA system.

Related Models of the Same Series (Hirschmann BOBCAT)

The BOBCAT platform is highly modular, offering a wide array of configurations under the BRS family:

BRS20-0600Z6Z6-STCZ99HHSES: 4 Fast RJ45 + 2 Fast SFP ports (Standard model).

BRS20-0600Z6Z6-S_TCZ99HHSES: Custom-configured with extended temperature ranges ($-40^circtext{C}$ to $+70^circtext{C}$).

BRS30 Series: Identical physical profile but supports Gigabit speeds on the uplink ports.

BRS40 Series: Supports All-Gigabit speeds across both copper and fiber ports for bandwidth-heavy application networks.

Storage Conditions

Proper storage ensures long-term reliability and prevents early degradation of delicate optical and terminal contacts:

Temperature Range: Keep strictly within the limits of $-40^circtext{C}$ to $+70^circtext{C}$.

Moisture Control: Maintain Relative Humidity under $95%$, ensuring a stable environment with no moisture condensation.

Storage Preparation: Store in original static-shielded packaging inside a clean, dry, and dust-free storage container.

 Keep terminal connectors capped until the moment of field installation.


  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module