DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
OMRON C200PC-ISA02-DRM-E PLC ISA bus compatible board card
❤ Add to collection

OMRON C200PC-ISA02-DRM-E PLC ISA bus compatible board card

OMRON C200PC-ISA02-DRM-E PLC ISA bus compatible board card

¥7500.00
¥6500.00
¥6500.00
¥6500.00
Weight:2.000KG
Description

OMRON C200PC-ISA02-DRM-E PLC ISA bus compatible board card




C200PC-ISA01-E

C200PC-ISA 2-DRM-E

C200PC-ISA 2-SRM-E

C200PC-EXP01

SYSMAC Board

Operation Manual

A SYSMAC Board is an ISA bus-compatible board that provides functionality

equivalent to a SYSMAC C200HG or C200HX PLC. It is installed as an expan

sion board in an IBM PC/AT or compatible computer. The features of the SYS

MAC Board are described next.

The SYSMAC Board is a fully functional PLC that operates within a personal

computer. It is functionally equivalent to the SYSMAC C200HG-CPU43-E or

C200HX-CPU64-E PLC. The equivalent PLC depends on the type of SYSMAC

Board used.

A Programming Device can be connected to the RS-232C port on the Board to

program it the same as a C200HX or C200HG PLC. Programming Devices can

be connected to either the RS-232C port or the peripheral port when an Expan

sion Option Board is used.

A C language library for the SYSMAC Board can be used in user applications

running on the computer to read/write Board memory, monitor Board status, and

control Board operation. In this sense, the computer can serve as a host com

puter for the SYSMAC Board.

The Microsoft C/C++ Ver. 7.0 C library is used, and small, medium, large, huge,

and compact memory models are supported. Windows Drivers, called the Fins

Gateway for Windows 95 and FinsGateway for Windows NT, are sold sepa

rately.

There are no I/O points provided on the Board itself, but it can be connected to up

to three C200HX or C200HG Expansion I/O Racks to enable I/O though

mounted I/O Units.

The Board is provided with 16K or 32K words of EEPROM built into it. This

EEPROM can be used exactly like the C200HW-ME16K and C200HW-ME32K

Memory Cassettes mounted to C200HX or C200HG PLCs. (The EEPROM can

not be removed from the Board.)

If a C200PC-EXP01 Expansion Option Board is used, the same RS-232C con

nector and peripheral connector as the C200HX or C200HG PLCs can be used.

The use of an Expansion Option Board enables the SYSMAC Board to be con

nected to other PLCs and Programming Console, and allows a rich variety of

communications, such as Host Link, RS-232C no-protocol, 1:1 PLC Link, 1:1 NT

Link, and 1:n NT Link communications, just as for C200HX or C200HG PLCs.

When an Expansion Option Board is used, however, the RS-232C port on the

SYSMAC Board cannot be used.

The following Special I/O Units for use with C200HX/HG/HE PLCs can be

mounted to the Expansion I/O Racks connected to the Board

1. If the SYSMAC Board uses fixed allocations for CompoBus/D Master func

tion or the CompoBus/D Master Unit, the words allocated in memory will

overlap with the area used for remote I/O, so the SYSMAC BUS Remote I/O

Master Unit cannot be used at the same time.

2. The Group-2 B7A Interface Units and Group-2 High-density I/O Units are

available in 32-point or 64-point models. Since 64-point models are allo

cated the words for two 32-point models, the maximum number of 64-point

models that can be mounted is half the number of 32-point models.

3. The maximum number of CompoBus/D Master Units that can be mounted

includes the SYSMAC Board’s CompoBus/D Master function.

If the SYSMAC Board uses fixed allocations for the CompoBus/D Master

function and CompoBus/D Master Unit, the words allocated in memory will

overlap with the area used for remote I/O. Therefore, only one CompoBus/D

Master Unit can be mounted (refer to 1-6 CompoBus/D Master Unit Func

tion), and SYSMAC BUS Remote I/O Master Units cannot be used at the

same time. The CompoBus/D Configurator must be used to allocated other

words if the fixed allocations are not used.

4. The maximum number of CompoBus/S Master Units that can be mounted

includes the SYSMAC Board’s CompoBus/S Master function.

If the SYSMAC Board’s CompoBus/S Master function and CompoBus/S

Master Unit are used when the number of Units that can be connected is set

to IN 0 to 15/OUT 0 to 15. twice the number of words will be used in the Spe

cial I/O Unit Area, so the maximum number of CompoBus/S Masters that

can be mounted will be halved. (Refer to 1-7 CompoBus/S Master Unit

Function.


  • SELSEL-T401L Ultra-High-Speed Line Relay
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-787 Transformer Protection Relay
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL-487E Transformer Protection Relay
  • SEL-400G Advanced Generator Protection System
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700BT Motor Bus Transfer Relay
  • CTI 2500 Series® Slice Ethernet Remote I/O System
  • CTI 2500 Series® Compact Programmable Automation Control System
  • CTI 2500 Series® Classic Programmable Automation Control System
  • CTI 2500 Series® Bases
  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • EATON Instructions for the FP-5000
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046