Description

OMRON  CJ1W-AD041-V1 Analog input uni


CJ1W-AD041-V1

Analog input unit, 4 x inputs 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA, resolution 1:4000 / 8000. screw terminal

Specifications

I/O system    CJ I/O Bus

Expansion unit type    Special I/O Unit

Type of module    Analog I/O

Number of analog inputs    4

Temperature input type    None

Linear analog input type    -10 to 10 V, 0 to 10 V, 0 to 5 V, 1 to 5 V, 4 to 20 mA

Resolution of the analog inputs    13 Bit

Input circuit type    Standard

Number of analog outputs    0

Linear analog output type    None

Resolution of the analog outputs    0 Bit

Conversion time    4000 ms/unit

I/O connection type    Screw

Number of I/O connectors    1

Detachable I/O terminal block

Suitable for safety functions

Product Height (unpacked)    90 mm

Product Width (unpacked)    31 mm

Product Depth (unpacked)    89 mm

Product Weight (unpacked)    150 g

The following example shows EM bank 2 converted to file memory.

EM File Memory setting: 1

(EM file memory enabled)

Peripheral Port Settings

EM Starting Bank setting: 2

Converted

EM file memory

These settings are effective only when pin 4 of the DIP switch on the front of

the CPU Unit is ON.

The default settings for the peripheral port are: host link mode, 1 start bit, 7

data bits, even parity, 2 stop bits, and a baud rate of 9.600 bps. Set the periph

eral port settings in the PLC Setup when you need to change these settings.

Note When pin 4 of the DIP switch on the front of the CPU Unit is OFF, the CPU

Unit automatically detects the communications parameters of a connected

Programming Device (including Programming Consoles). Those automatically

detected parameters are not stored in the PLC Setup.

S-073N   3BHB009884R0021 Frame ABB Semiconductor thyristor
S-093H 3BHB009885R0004 Semiconductor   thyristor ABB
S-113H 3BHB018008R0003 Semiconductor   thyristor ABB
PR6423/000-031-CN+CON021 Cover vibration   sensor EPRO
USI-0002 HONEYWELL Universal Safety   Interface
AKM33E-ANCNR-00 KOLLMORGEN AKMSeries   Servo Motor
CC-GAIX21 HONEYWELL Universal Marshalling   Solution for Safety Systems
RAUMASTC-2 AQUAMASTER Digital stepping   motor and driver
SR511 3BSE000863R0001 ABB SR511 Regulator   24V/5V
MTL4549C MTL ISOLATING DRIVER
SCE905AN-002-01 High Performance Digital   Servo Drive PACIFIC
VS3202 SLS1508 DeltaV SISLogic Solver   EMERSON
ACC-68E Delta Tau Digital input and   output cards
1756-OX8I Allen-Bradley ControlLogix   Discrete output module
SDO-0824 HONEYWELL Safe Digital Output   FTA
SDI-1624 HONEYWELL Safe Digital Output   FTA

SYSMAC

CJ1G-CPU44

PROGRAMMABLE

CONTROLLER

OPEN

RUN

ERR/ALM

INH

PRPHL

COMM

MCPWR

BUSY

PERIPHERAL

PORT

RS-232C Port Settings

Peripheral port communications settings when DIP

Switch pin 4 is ON:

Default settings:

Host link mode, 1 start bit, 7 data bits, even parity,

2 stop bits, and a baud rate of 9.600 bps

User-defined settings:

Set the communications mode (host link, NT Link,

or peripheral bus) and other settings such as the

baud rate.

These settings are effective only when pin 5 of the DIP switch on the front of

the CPU Unit is OFF.

The default settings for the RS-232C port are: host link mode, 1 start bit, 7

data bits, even parity, 2 stop bits, and a baud rate of 9.600 bps. Set the RS

232C port settings in the PLC Setup when you need to change these settings.

Specify the frame format when no-protocol mode is selected.

The RS-232C port settings can also be changed with STUP(237). The RS

232C Port Settings Changing Flag (A61902) is turned ON when STUP(237) is

executed and it is turned OFF when the RS-232C port settings have been

changed


  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer