OMRON CJ1W-AD041-V1 Analog input uni
CJ1W-AD041-V1
Analog input unit, 4 x inputs 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA, resolution 1:4000 / 8000. screw terminal
Specifications
I/O system CJ I/O Bus
Expansion unit type Special I/O Unit
Type of module Analog I/O
Number of analog inputs 4
Temperature input type None
Linear analog input type -10 to 10 V, 0 to 10 V, 0 to 5 V, 1 to 5 V, 4 to 20 mA
Resolution of the analog inputs 13 Bit
Input circuit type Standard
Number of analog outputs 0
Linear analog output type None
Resolution of the analog outputs 0 Bit
Conversion time 4000 ms/unit
I/O connection type Screw
Number of I/O connectors 1
Detachable I/O terminal block
Suitable for safety functions
Product Height (unpacked) 90 mm
Product Width (unpacked) 31 mm
Product Depth (unpacked) 89 mm
Product Weight (unpacked) 150 g
The following example shows EM bank 2 converted to file memory.
EM File Memory setting: 1
(EM file memory enabled)
Peripheral Port Settings
EM Starting Bank setting: 2
Converted
EM file memory
These settings are effective only when pin 4 of the DIP switch on the front of
the CPU Unit is ON.
The default settings for the peripheral port are: host link mode, 1 start bit, 7
data bits, even parity, 2 stop bits, and a baud rate of 9.600 bps. Set the periph
eral port settings in the PLC Setup when you need to change these settings.
Note When pin 4 of the DIP switch on the front of the CPU Unit is OFF, the CPU
Unit automatically detects the communications parameters of a connected
Programming Device (including Programming Consoles). Those automatically
detected parameters are not stored in the PLC Setup.
| S-073N 3BHB009884R0021 Frame ABB Semiconductor thyristor |
| S-093H 3BHB009885R0004 Semiconductor thyristor ABB |
| S-113H 3BHB018008R0003 Semiconductor thyristor ABB |
| PR6423/000-031-CN+CON021 Cover vibration sensor EPRO |
| USI-0002 HONEYWELL Universal Safety Interface |
| AKM33E-ANCNR-00 KOLLMORGEN AKMSeries Servo Motor |
| CC-GAIX21 HONEYWELL Universal Marshalling Solution for Safety Systems |
| RAUMASTC-2 AQUAMASTER Digital stepping motor and driver |
| SR511 3BSE000863R0001 ABB SR511 Regulator 24V/5V |
| MTL4549C MTL ISOLATING DRIVER |
| SCE905AN-002-01 High Performance Digital Servo Drive PACIFIC |
| VS3202 SLS1508 DeltaV SISLogic Solver EMERSON |
| ACC-68E Delta Tau Digital input and output cards |
| 1756-OX8I Allen-Bradley ControlLogix Discrete output module |
| SDO-0824 HONEYWELL Safe Digital Output FTA |
| SDI-1624 HONEYWELL Safe Digital Output FTA |
SYSMAC
CJ1G-CPU44
PROGRAMMABLE
CONTROLLER
OPEN
RUN
ERR/ALM
INH
PRPHL
COMM
MCPWR
BUSY
PERIPHERAL
PORT
RS-232C Port Settings
Peripheral port communications settings when DIP
Switch pin 4 is ON:
Default settings:
Host link mode, 1 start bit, 7 data bits, even parity,
2 stop bits, and a baud rate of 9.600 bps
User-defined settings:
Set the communications mode (host link, NT Link,
or peripheral bus) and other settings such as the
baud rate.
These settings are effective only when pin 5 of the DIP switch on the front of
the CPU Unit is OFF.
The default settings for the RS-232C port are: host link mode, 1 start bit, 7
data bits, even parity, 2 stop bits, and a baud rate of 9.600 bps. Set the RS
232C port settings in the PLC Setup when you need to change these settings.
Specify the frame format when no-protocol mode is selected.
The RS-232C port settings can also be changed with STUP(237). The RS
232C Port Settings Changing Flag (A61902) is turned ON when STUP(237) is
executed and it is turned OFF when the RS-232C port settings have been
changed