Omron CP1E-N60DR-D Compact PLC CPU
Omron CP1E-N60DR-D Compact PLC CPU
1. If CX-Programmer Ver. 3.2 or a lower version is used to read a task with
task read protection applied, an error will occur and the task will not be
read. Likewise, if a Programming Console or the PT Ladder Monitor func
tion is used to read a password protected task, an error will occur and the
task will not be read.
2. The entire program can be transferred to another CPU Unit even if individ
ual tasks in the program are read-protected. It is also possible to connect
online and create a program file (.OBJ file) with file memory operations. In
both cases, the task read protection remains effective for the password
protected tasks.
3. When the CX-Programmer is used to compare a user program in the com
puter's memory with a user program in the CPU Unit, password-protected
tasks will be compared too.
Restrictions to Function
Block Use
Function block definitions can be read even if the entire program or individual
tasks in a program containing function blocks (CPU Unit Ver. 3.0 or later only)
are read-protected.
Enabling/Disabling Creating File Memory Program Files
Previous CPU Units (Pre
Ver. 2.0 CPU Units)
CPU Unit Ver. 2.0 or Later
and CX-Programmer
Ver. 4.0 or Higher
With the pre-Ver. 2.0 CS/CJ-series CPU Units, it was possible use file mem
ory operations to transfer a program file (.OBJ file) to a Memory Card even if
the program was protected with UM read protection. (Consequently, illegal
copies could be made.)
| ACS580-01-246A-4 ABB LV AC general purpose drive module |
| G122-829A001 MOOG P-I Servoamplifier |
| EASYGEN-3500-XT-P2-LT Woodward easYgen-3500XT Series paralleling genset controllers |
| MC07B0008-5A3-4-SO/FSC11B/DFE MKD Synchronous Motors REXROTH |
| XV-303-15-C02-A00-1B Touch panel EATON |
| 605-707109-012 PCB Indexer Interface LAM 810-001486-002 |
| T8442 Ics Triplex Trusted TMR Speed Monitor |
| S70102-NANANA servo driver KOLLMORGEN |
| XVS-440-57MP1-1-1U Touch panel EATON |
| PCIE-5565-PIORC-100000 GE PCIE-5565RC Interface Card |
| XVS-450-57MP1-1-10 Touch panel EATON |
| A06B-6220-H045#H600 B FANUC SPINDLE MODULE MDL SPM-15 |
| VD4M1206-25 ABB vacuum circuit breaker |
| A06B-6200-H055 B FANUC SPINDLE MODULE MDL SPM-15 |
Overview
When the entire program or individual tasks in a CPU Unit Ver. 2.0 or later are
read-protected from the CX-Programmer, an option can be set to enable or
disable the creation/backup of .OBJ program files. It will not be possible to
create program files (.OBJ files) with file memory operations if the creation/
backup of program files is prohibited with this setting. (This setting prohibits
both online transfers to a Memory Card/EM file memory as well as offline stor
age of PLC data that was uploaded to the CX-Programmer.)
Disabling the creation of file memory program files can help prevent illegal
copying of the user program
Operating Procedure
1.2.3...
1. When registering a password in the UM read protection password Box or
Task read protection Box, select the Prohibit from saving into a protected
memory card Option.
Properties
2. Either select PLC - Transfer - To PLC to transfer the program or select
PLC - Protection - Set Password and click the OK button.
Usage
This option can be used to prevent the program from being transferred out of
the PLC using the password.
Note
1. The simple backup operation can still be performed when the creation of
program files is prohibited, but the backup program file (BACKUP.OBJ) will
not be created.
2. The program can be copied when program read protection is not enabled.
3. The setting to enable/disable creating file memory program files will not
take effect unless the program is transferred to the CPU Unit. Always trans
fer the program after changing this setting.
Enabling/Disabling Write Protection for Individual Tasks Using Passwords
Previous CPU Units (Pre
Ver. 2.0 CPU Units)
With the pre-Ver. 2.0 CS/CJ-series CPU Units, the CPU Unit's user program
memory (UM) can be write-protected by turning ON pin 1 of the CPU Unit's
DIP switch. In this case, it is possible to overwrite the user program memory
by turning OFF pin 1.
CPU Unit Ver. 2.0 or Later
and CX-Programmer
Ver. 4.0 or Higher
With the CPU Unit Ver. 2.0 and later CPU Units, the CPU Unit's UM area can
be write protected by turning ON pin 1 of the CPU Unit's DIP switch. The pro
gram (or selected tasks) can also be write-protected if the write protection
option is selected from the CX-Programmer when a password is being regis
tered for the entire program or those selected tasks. The write protection set
ting can prevent unauthorized or accidental overwriting of the program.