DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC
❤ Add to collection

ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC

ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC

8760.00
¥7450.00
¥7450.00
¥7450.00
Weight:2.000KG
Description

ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC


ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC

Product Introduction / Overview

The ADLINK CPCI-6910AM-M1G is an industrial-grade, high-performance 6U CompactPCI Single Board Computer (SBC) powered by an Intel Dual-Core Xeon processor. 

Built for mission-critical automation, defense systems, telecommunications, and heavy industrial processing, the board provides multi-threaded processing power coupled with robust thermal management and extensive front/rear I/O connectivity.

Featuring universal system/peripheral slot compatibility, the CPCI-6910 series enables dual-system control capabilities across standard PICMG 2.0 backplanes while maintaining shock and vibration resistance required in extreme environments.

Technical Table

Specification ParameterDetails & Technical Values
ManufacturerADLINK Technology Inc.
Model / Part NumberCPCI-6910AM-M1G
Form Factor6U CompactPCI (Single-Slot 4TE / ~20mm width)
ProcessorIntel Dual-Core Xeon Low Voltage (LV) Processor
ChipsetIntel E7520 / 6300ESB I/O Controller Hub
System MemoryOnboard DDR2 Registered ECC SDRAM (1 GB Default, expandable via SODIMM)
Bus Architecture64-bit / 66 MHz PCI-X Bus Interface
Front Panel I/O

• 1x VGA Video Output (DB-15)


• 2x Gigabit Ethernet (RJ-45)


• 2x USB 2.0 Ports


• 1x RS-232 Serial COM Port (RJ-45 or DB-9)

Rear I/O (Backplane)PICMG 2.16 Packet Switching Backplane / Rear Transition Module (RTM) support via J3/J4/J5
Expansion Slots64-bit PMC Expansion Slot (PMC-1 / PMC-2 support)
Watchdog TimerDual-stage programmable timer (1 to 255 seconds)

Environmental Tolerance Conditions

Operating Temperature: 0°C to +55°C (Standard Forced Air Cooling) / -20°C to +70°C (Extended Temp / Rugged Variant)

Storage Temperature: -40°C to +85°C

Relative Humidity: 5% to 95% at 40°C (Non-condensing)

Operating Vibration: 5 Hz to 500 Hz, 2.0 Grms (random, 3 axes)

Shock Resistance: 15 G peak acceleration, 11 ms duration (half-sine wave)

Operating Instructions

Pre-Installation Alignment: Inspect the backplane J1–J5 pin headers on the 6U rack to ensure no bent pins or debris exist before mounting.

Card Insertion: Slide the CPCI-6910AM-M1G into the designated system master or peripheral slot along the guide rails.

Ejector Handle Lock: Firmly press the top and bottom red-button ejector handles inward until the board fully seats into the backplane connectors. Tighten the retaining screws.

BIOS Setup: Access the system BIOS by pressing DEL or F2 at boot up to configure boot priority (CompactFlash, PMC storage, or PXE Network Boot).

Fault Diagnosis

Symptom / LED StatePotential CauseSolution / Diagnostic Action
POST LED Off / BlankBackplane power supply failure or seating mismatch.Verify +5V, +3.3V, and +12V rail outputs from the rack power supply; reseat card.
Status LED Solid RedProcessor overheating or watchdog timeout.Clean intake fan filters; inspect CPU heatsink compound and thermal dissipation.
No Display via VGAVideo memory allocation issue or jumper configuration error.Check BIOS display output settings; test with a secondary RAM module.
PXE Boot FailsNetwork controller initialization timed out.Verify LAN link speed LEDs on the front panel and confirm PICMG 2.16 routing settings.

Related Models of the Same Series

CPCI-6910/DCX20/M2G: Dual-Core Xeon variant equipped with 2 GB onboard DDR2 ECC memory.

CPCI-6910/LV14/M1G: Single/Low-Voltage Intel Pentium M / Xeon option for lower power dissipation setups.

cPCI-R6910: Corresponding 6U Rear Transition Module (RTM) for rear cabling routing.

Storage Conditions

To prevent signal degradation or ESD damage during long-term storage:

Store in an ESD-shielded anti-static bag with desiccant packs.

Maintain ambient storage temperatures between -40°C and +85°C.

Avoid areas exposed to direct corrosive gases, high humidity (>95%), or excessive atmospheric condensation.



  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications