DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
VIBRO-METER  CPU controller  CPUR
❤ Add to collection

VIBRO-METER CPU controller CPUR

VIBRO-METER  CPU controller  CPUR

¥10030.00
¥9860.00
¥9860.00
¥9860.00
Weight:2.000KG
Description

VIBRO-METER  CPU controller  CPUR






CPU controller  CPUR

VIBRO-METER CPUR (Central Processing Unit Rack Card) is the core rack controller module for Meggitt’s Vibro-Meter VM600 series machinery protection and condition monitoring systems. Installed in slot 0 or slot 1 of a VM600 rack, the CPUR acts as the communication and processing hub, interfacing individual protection cards (such as MPC4) with external DCS, SCADA, or condition monitoring software via industrial fieldbus protocols.

Technical Parameter List

ParameterSpecification
ManufacturerMeggitt (Vibro-Meter)
SeriesVM600 Machinery Protection System (MPS)
Processor TypeHigh-performance 32-bit embedded RISC processor
System Bus InterfaceVM600 proprietary VMEbus backplane
Communication ProtocolsModbus RTU / Modbus TCP, Ethernet (10/100Base-T), RS-232/RS-485
Display / User InterfaceFront-panel LCD status display with navigation buttons
Input Voltage Supply+5 VDC and ±12 VDC (supplied internally via VM600 system power supply)
Power ConsumptionApprox. 10 W (typical)
Form FactorStandard Eurocard 6U rack card
Associated IO CardIOC-R (Input/Output Card for CPUR, mounted at rear)

Product Features / Core Advantages

Centralized Data Aggregation: Continuously gathers dynamic vibration, position, temperature, and speed data from all processing cards across the VM600 rack.

Dual Redundancy Options: Supports redundant rack controller configurations (CPUR + IOC-R paired) for mission-critical API 670 machinery protection systems.

Multi-Protocol Gateways: Native support for Modbus TCP/RTU allows seamless integration into Siemens, Honeywell, Emerson, and ABB DCS/PLC networks.

On-Board LCD Diagnostics: Real-time system health checks, rack configuration parameters, IP settings, and error codes displayed directly on the front panel.

Hot-Swappable Design: Can be safely removed and replaced during live rack operation without interrupting hardware protection relay triggers on MPC4 cards.

Model Classification & Ordering Information

The CPUR card is part of the VM600 rack controller family and is typically specified alongside its paired rear I/O card:

CPUR Card (Front Module):

200-510-000-HHH (Standard CPUR Rack Controller Card)

CPUR 1-slot 6U card variant

Associated Rear Cards & Accessories:

IOC-R: 200-560-000-HHH (Input/Output card for CPUR, housing Ethernet and RS-485 ports)

VM600 Rack Types: ABE040 (19" 6U System Rack) / ABE042 (19" 6U Slim Rack)

Environmental Tolerance Conditions

ConditionOperating LimitsStorage Limits
Temperature-20°C to +65°C (-4°F to 149°F)-40°C to +85°C (-40°F to 185°F)
Relative Humidity0% to 95% non-condensing0% to 95% non-condensing
Vibration Resistance2 g peak at 10 to 150 HzIEC 60068-2-6 standard
Shock Resistance15 g acceleration (11 ms duration)IEC 60068-2-27 standard
Hazardous ApprovalsATEX / IECEx Zone 2, CSA Class I Div 2ISO 9001 quality compliance

Installation Method

1.Power & ESD Preparation:Ensure rack grounding and static protection before handling。

Verify the VM600 rack is grounded via its main earth terminal. Wear a grounded wrist strap to prevent ESD damage to board-level components.

2.Mount the Rear IOC-R Card:Insert into the rear slot corresponding to slot 0/1.

Align the IOC-R card with the rear guide rails directly behind the designated CPUR slot. Slide in smoothly until backplane connectors mate, then tighten top and bottom captive screws.

3.Insert the CPUR Front Card:Align with front slot guide rails。

Slide the CPUR module into Slot 0 (or Slot 1 for redundant setups) from the front panel. Push the card in firmly until the injector handle locks into place with the rack frame.

4.Secure Fasteners & Connect Cables:Tighten screws and attach Ethernet/Serial cables。

Tighten the two front panel captive screws. Attach Ethernet (RJ45) and serial cables (DB9/RS-485 terminals) to the corresponding IOC-R card on the rear.

Operating Instructions

Initial Network Setup:

Connect a PC running Vibro-Meter VM600 MPSX / VibroSight software to the Ethernet port on the IOC-R card. Configure the static IP address, subnet mask, and Modbus device ID using the front-panel menu or configuration tool.

Status LED Monitoring:

OK (Green): Normal CPU operation and backplane communication active.

DIAG / ALARM (Yellow/Red): Communication loss, hardware fault, or rack configuration mismatch.

Modbus Register Mapping:

Map the Modbus register addresses in your DCS to read dynamic values (e.g., overall vibration, peak 1X amplitude, gap voltage) collected by the CPUR from the MPC4/TPC6 modules.

Maintenance & Firmware Upgrades:

Perform periodic backups of the CPUR configuration via VibroSight software prior to any system maintenance or firmware updates.


  • SAUTER AXT 201. 211: Thermal actuator for unit valves with stroke
  • SAUTER AXS 215S: Continuous actuator for unit valves, with stroke
  • SAUTER AXM 217S: Motorised actuator for unit valves with positioner
  • SAUTER AVM 321S, 322S: Valve actuator
  • SAUTER AVM234S: SUT valve actuator with positioner
  • SAUTER AVM 105. 115: Valve actuator
  • SAUTER AVF 234S: SUT valve actuator with spring return
  • SAUTER AVF124: Actuator with spring return
  • SAUTER AKM115SAF332: Smart Actuator for ball valve, BACnet/IP
  • SAUTER AKM115SA: Smart Actuator for ball valve
  • AKM 105S, 115S: Rotary actuator with SAUTER Universal
  • SAUTER AKM 105. 115: Rotary actuator for ball valve
  • SAUTER AVM 234S: SUT valve actuator with positioner
  • SELSEL-T401L Ultra-High-Speed Line Relay
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-787 Transformer Protection Relay
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL-487E Transformer Protection Relay
  • SEL-400G Advanced Generator Protection System
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700BT Motor Bus Transfer Relay
  • CTI 2500 Series® Slice Ethernet Remote I/O System
  • CTI 2500 Series® Compact Programmable Automation Control System
  • CTI 2500 Series® Classic Programmable Automation Control System
  • CTI 2500 Series® Bases
  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • EATON Instructions for the FP-5000
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671