DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
OMRON CS1H-CPU63-EV1 PLC
❤ Add to collection

OMRON CS1H-CPU63-EV1 PLC

OMRON CS1H-CPU63-EV1 PLC

9870.00
¥8564.00
¥8564.00
¥8564.00
Weight:2.000KG
Description

OMRON CS1H-CPU63-EV1 PLC


OMRON CS1H-CPU63-EV1 PLC 

Item Specifications

EM Area

32K words per bank, 13 banks max.: E0_00000 to EC_32767 max. (Varies by CPU Unit model.)

Used as a general-purpose data area for reading and writing data in word units (16 bits). Words in the EM Area maintain their status when

the PLC is turned OFF or the operating mode is changed.

The EM Area is divided into banks, and the addresses can be set by either of the following methods.

Changing the current bank using the EMBC(281) instruction and setting addresses for the current bank. Setting bank numbers and

addresses directly.

EM data can be stored in files by specifying the number of the first bank.

Data Registers DR0 to DR15: Store offset values for indirect addressing. One register is 16 bits (1 word).

Index Registers IR0 to IR15: Store PLC memory addresses for indirect addressing. One register is 32 bits (2 words).

Task Flag Area 32 (TK0000 to TK0031): Task Flags are read-only flags that are ON when the corresponding cyclic task is executable and OFF when the

corresponding task is not executable or in standby status.

Trace Memory 4.000 words (The maximum amount of data that can be traced in a data trace is 500 samples for 31 bits and 6 words.

File Memory Memory Cards: Compact flash memory cards can be used (MS-DOS format).

EM file memory: Part of the EM Area can be converted to file memory (MS-DOS format).

Functions

Parallel Processing

Modes Program execution and peripheral servicing can be performed simultaneously.

Battery-free operation The user program and the system’s parameters are backed up automatically in flash memory, which is standard equipment.

Constant cycle time Possible (1 to 32.000 ms) (Unit: 1 ms)

Cycle time monitoring Possible (Unit stops operating if the cycle is too long): 10 to 40.000 ms (Unit: 10 ms)

I/O refreshing Cyclic refreshing, immediate refreshing, refreshing with I/O REFRESH instruction

I/O memory holding

when changing

operating modes

Possible (Depends on the ON/OFF status of the IOM Hold Bit in the Auxiliary Area.)

Load OFF All outputs on Output Units can be turned OFF.

Input response time

setting

Time constants can be set for inputs from Basic I/O Units.

The time constant can be increased to reduce the influence of noise and chattering or it can be decreased to detect shorter pulses on the

inputs (CS1 Basic I/O Units only).

Startup mode setting Supported.

Memory Card

functions

Automatically reading programs (autoboot) from the Memory Card when the power is turned ON.

Format in which data is stored in Memory Card

User program: Program file format

PLC Setup and other parameters: Data file format (binary format)

I/O memory: Data file format (binary format), text format, or CSV format

Functions for which Memory Card read/write is

supported

User program instructions, Programming Devices (including Programming Consoles),

Host Link computers

Filing Memory Card data and the EM (Extended Data Memory) Area can be handled as files.

Debugging Control set/reset, differential monitoring, data tracing (scheduled, each cycle, or when instruction is executed), storing location generating

error when a program error occurs

Online editing User programs can be overwritten in program-block units when the CPU Unit is in MONITOR or PROGRAM mode.

(This function is not available for block programming areas.)

Program protection Overwrite protection: Set using DIP switch.

Copy protection: Password set using Programming Device.

Error check User-defined errors (i.e., user can define fatal errors and non-fatal errors)

The FPD(269) instruction can be used to check the execution time and logic of each programming block.

Error log Up to 20 errors are stored in the error log. Information includes the error code, error details, and the time the error occurred.

Serial

communications

Built-in peripheral port: Programming Device (including Programming Console) connections, Host Links, NT Links

Built-in RS-232C port: Programming Device (excluding Programming Console) connections, Host Links, no-protocol communications, NT

Links, and Serial Gateway  *3

Serial communications board (order separately): protocol macros, Host Links, no-protocol communications *3. NT Links, Serial Gateway

*3. and Modbus-RTU Slave *5

Clock Provided on all models.

Note: Used to store the time when power is turned ON and when errors occur.

Power OFF detection

time 10 to 25 ms (not fixed)

Power OFF detection

delay time 0 to 10 ms (user-defined, default: 0 ms)

Memory retention

during power

interruptions

Held Areas: Holding bits, contents of Data Memory and Extended Data Memory, and status of the counter Completion Flags and present

values.

Note: If the IOM Hold Bit in the Auxiliary Area is turned ON, and the PLC Setup is set to maintain the IOM Hold Bit status when power to

the PLC is turned ON, the contents of the CIO Area, the Work Area, part of the Auxiliary Area, timer Completion Flags and PVs, Index

Registers, and the Data Registers will be saved.

Sending commands to

a Host Link comput


  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor