DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
OMRON CS1W-EIP21 PLC
❤ Add to collection

OMRON CS1W-EIP21 PLC

OMRON CS1W-EIP21 PLC

5790.00
¥4780.00
¥4780.00
¥4780.00
Weight:2.000KG
Description

OMRON CS1W-EIP21 PLC


OMRON CS1W-EIP21 PLC

The bits in the ranges shown below have specific functions, but can still be used

as work bits when their specific functions are not being used.

Range

IR 096 to IR 099

Function

When the MACRO instruction is used, these bits serve as op

erand input bits.

IR 196 to IR 199

When the MACRO instruction is used, these bits serve as op

erand output bits.

IR 230 to IR 231

When high-speed counter is used, these bits are used to store

its present value.

LR 00 to LR 63 are used as link bits, but they can also be used as work bits when

not linked to another ID Controller. Refer to the CQM1 Programming Manual for

details on using link bits in 1-to-1 communications.

These bits mainly serve as flags related to ID Controller operation. For details on

the various bit functions, refer to Appendix D AR and SR Area Allocations.

SR 244 to SR 247 can also be used as work bits, when input interrupts are not

used in Counter Mode.

When a complex ladder diagram cannot be programmed in mnemonic code just

as it is, these bits are used to temporarily store ON/OFF execution conditions at

program branches. They are used only for mnemonic code. When programming

directly with ladder diagrams using the Ladder Support Software (LSS) or SYS

MAC Support Software (SSS), TR bits are automatically processed for you.

The same TR bits cannot be used more than once within the same instruction

block, but can be used again in different instruction blocks. The ON/OFF status

of TR bits cannot be monitored from a Peripheral Device.

These bits retain their ON/OFF status even after the ID Controller power supply

has been turned off or when operation begins or stops. They are used in the

same way as work bits.

1768-PA3 Allen   Bradley CompactLogix Power Supply
VE4001S2T2B7 EMERSON Discrete Input Card
MPL-B580J-SJ22AA Allen Bradley Premium   permanent magnet rotary servo motor
SST-PB3-PCIE-2 PROFIBUS Interface PCI   Card Molex
330103-00-07-50-02-05 Bently Nevada 3300   XL 8 mm Probe
VT-VPCD-1-1X/V0/1-0-1 REXROTH Electronic   signal amplifier
810-186753-002 PCB Indexer Interface LAM   810-800081-022
2711P-PR8DK Allen Bradley PanelView Plus   6 Operator Terminal
2711P-K4M20D8 Allen Bradley Panelview   Plus 6 400 Operator Terminal
PXle-8133 NI Embedded Controller for PXI   and CompactPCI
MC07B0030-5A3-4-00 MKD Synchronous Motors   REXROTH
1756-IRT6I Allen-Bradley ControlLogix   analog input module
810-141735-005 PCB Indexer Interface LAM
ADV551-P60/D5S00 YOKOGAWA  Digital   Input Modules
ADV151-P60/B5S00 YOKOGAWA  Digital   Input Modules
MTL4544S MTL ISOLATING DRIVER
MTL4546Y MTL ISOLATING DRIVER
A02B-0333-C263 FANUC Robot teaching   device

These bits mainly serve as flags related to ID Controller operation. For details on

the various bit functions, refer to relevant sections in this manual or to Appen

dix D AR and SR Area Allocations.

When the ID Controller is linked one to one with another ID Controller, these bits

are used to share data. Refer to the CQM1 Programming Manual for details on

using link bits in 1-to-1 communications.

LR bits can be used as work bits when not used for data links.

Timers/Counters Area

This area is used to manage timers and counters created with TIM, TIMH(15),

CNT, and CNTR(12). The same numbers are used for both timers and counters

and each number can be used only once in the user program. Do not use the

same TC number twice even for different instructions.

TC number are used to create timers and counters, as well as to access Comple

tion Flags and present values (PVs). If a TC number is designated for word data,

it will access the present value (PV); if it is used for bit data, it access the Comple

tion Flag for the timer/counter.

The Completion Flag turns ON when the PV of the timer/counter that is being

used goes to 0.

Refer to the CQM1 Programming Manual for details on timers and counters.

Note 1. TC numbers 000 through 015 and interrupt processing should be used for

TIMH(15) whenever the cycle time is longer than 10 ms. Using other timer/

counter numbers or not using interrupt processing will lead to inaccuracy in

the high-speed timers. Interrupt processing can be set in DM 6629 of the ID

Controller Setup.

2. When the input condition turns OFF for TIM or TIMH(15), the PV is reset and

returns to the set value. The PV is also reset at the beginning of program

execution or when the interlock condition goes OFF in a interlocked pro

gram section (IL–ILC). The PV for CNT or CNTR(12) is not reset like one for

the timer instruction, but rather is reset only when the reset input goes ON


  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor