DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
Basler Electric DECS-250-CN2CN 1N Digital Excitation Control System Unit
❤ Add to collection

Basler Electric DECS-250-CN2CN 1N Digital Excitation Control System Unit

Basler Electric DECS-250-CN2CN 1N Digital Excitation Control System Unit

9170.00
¥8560.00
¥8560.00
¥8560.00
Weight:2.000KG
Description

Basler Electric DECS-250-CN2CN 1N Digital Excitation Control System Unit


Basler Electric DECS-250 - CN2CN 1N Digital Excitation Control System Unit

output contact including OUTA. Over 20 alarm conditions are available to be monitored including user

definable logic conditions using BESTlogic.

Active alarms can be read and reset from the front panel HMI or from the communication ports. A

historical sequence of events report with time stamps lists when each alarm occurred and cleared. These

reports are available through the communication ports.

Version Report

The version of the embedded software (firmware) is available from the front panel HMI or the

communication ports. The unit serial number and style number is also available through the

communication port.

BESTlogic™ Programmable Logic

Each BE1-GPS100 protection and control function is implemented in an independent function element.

Every function block is equivalent to its single function, discrete device counterpart so it is immediately

familiar to the protection engineer. Each independent function block has all of the inputs and outputs that

the discrete component counterpart might have. Programming with BESTlogic is equivalent to choosing

the devices required by your protection and control scheme and then drawing schematic diagrams to

connect the inputs and outputs to obtain the desired operating logic.

Several preprogrammed logic schemes and a set of custom logic settings are provided. A

preprogrammed scheme can be activated by merely selecting it. Custom logic settings allow you to tailor

the relay functionality to match the needs of your operation's practices and power system requirements.

Write Access Security

Security can be defined for three distinct functional access areas: Settings, Reports, and Control. Each

access area can be assigned its own password. A global password provides access to all three functional

areas. Each of the four passwords can be unique or multiple access areas can share the same password.

A second dimension of security is provided by allowing the user to restrict access for any of the access

areas to only specific communication ports. For example, you could set up security to deny access to

control commands from the rear RS-232 port that is connected through a modem to a telephone line.

Security settings only affect write access. Read access is always available in any area through any port.

Human-Machine Interface (HMI)

Each BE1-GPS100 comes with a front panel display with five LED indicators for Power Supply Status,

Relay Trouble Alarm, Minor Alarm, Major Alarm, and Trip. The lighted, liquid crystal display (LCD) allows

the relay to replace local indication and control functions such as panel metering, alarm annunciation, and

control switches. Four scrolling pushbuttons on the front panel provide a means to navigate through the

menu tree. Edit and Reset pushbuttons provide access to change parameters and reset targets, alarms

and other registers. In Edit mode, the scrolling pushbuttons provide data entry selections. Edit mode is

indicated by an LED on the Edit pushbutton.

The LCD has automatic priority logic to govern what is being displayed on the screen so that when an

operator approaches, the information of most interest is automatically displayed without having to

navigate the menu structure. The order of priorities is:

1. Targets

2. Alarms

3. Programmable automatic scrolling list

Up to 16 screens can be defined in the programmable, automatic scroll list.

Communication

Three independent, isolated communication ports provide access to all functions in the relay. COM 0 is a

9-pin RS-232 port located on the front of the case. COM 1 is a 9-pin RS-232 port located on the back of

the case. COM 2 is a two wire RS-485 port located on the back of the case.

An ASCII command interface allows easy interaction with the relay, using standard, off the shelf

communication software. The ASCII command interface is optimized to allow automation of the relay

setting process. Settings files can be captured from the relay and edited using any software that supports

the *.txt file format. These ASCII text files can then be used to set the relay using the send text file

function of your communication software.

ASCII, Modbus™, DNP3. and Basler TNP protocols are optionally available for the RS-485

communication port. A separate instruction manual is available for each available protocol. Consult the

product bulletin or the factory for availability of these options and instruction manuals.

Primary Applications

The BE1-GPS100 Generator Protection System provides three-phase, ground, negative sequence

overcurrent, voltage, reverse power, loss of excitation, volts per hertz, and sync-check protection. It is

intended for use in any generator protection application. Its unique capabilities make it ideally suited for

applications where:

• Wide setting range, multiple setting groups, multiple coordination curves, and versatile

programmable logic is desired in one unit.

• One economical, space-saving unit provides all protection, control, metering, and local and

remote indication functions.

• Applications where a small-size relay with limited behind-panel projection facilitates modernizing

protection, metering, and control systems in existing substations is desired.

• Protection redundancy is desired by having differential relaying in an independent, protective

relaying package.

• Communication and protocol support is required.

• Drawout construction is desired.

• High accuracy across a wide frequency range is required.

• The capabilities of intelligent electronic devices (IEDs) are used to decrease relay and equipment

maintenance costs.

Model and Style Number Description

General

The BE1-GPS100 Relay electrical characteristics and operational features are defined by a combination

of letters and numbers that make up the style number. The model number, together with the style

number, describe the options included in a specific device and appear in the clear window on the front

panel and on a sticker located inside the case. Upon receipt of a relay, be sure to check the style number

against the requisition and the packing list to ensure that they agree.

Sample Style Number

Style number identification chart, Figure 1-1. defines the electrical characteristics and operational features

included in BE1-GPS100 Relays. For example, if the style number were E3N1R0U, the device would

have the following characteristics and features:

BE1-GPS100 —

(E)  - 5 ampere nominal system with 5 ampere independent ground input

(U)  - Three-phase voltage sensing - Not applicable - 48/125 Vac/Vdc power supply - Single ended case, normally open alarm output - ASCII communication - Battery backup for real time clock


  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module