BASLER ELECTRIC DECS-250-LN1SN1N DIGITAL EXCITATION CONTROL SYSTEM
BASLER ELECTRIC DECS-250-LN1SN1N DIGITAL EXCITATION CONTROL SYSTEM
Metered Frequency Values and Accuracy
Range ............................................................................. 10 to 75 hertz
Accuracy ......................................................................... ±0.01 hertz, ±1 least significant digit at 25°C
Minimum Frequency Tracking Voltage ........................... 10 V RMS
3-wire Sensing Input ....................................................... Phase A - B
4-wire Sensing Input ....................................................... Phase A - Neutral
Slip Frequency
Range ............................................................................. ±10 hertz
Accuracy ......................................................................... ±0.01 hertz, ±1 least significant digit at 25°C
Phase Angle
Range ............................................................................. –180° to 0° to +180°
Accuracy ......................................................................... ±0.5°
Calculated Values and Accuracy
Demand
Range ............................................................................. 0.1 to 1.5 nominal
Type ................................................................................ Exponential
Accuracy ......................................................................... ±1% of reading, ±1 digit at 25°C
Temperature Dependence .............................................. ≤ ±0.02% per °C
Interval ............................................................................ 1 to 60 minutes
True Power
5 Ampere CT Range ....................................................... −7.500 W to +7.500 W
1 Ampere CT Range ....................................................... −1.500 W to +1.500 W
Accuracy ......................................................................... ±1% at unity power factor
Reactive Power
5 Ampere CT Range ....................................................... −7.500 var to +7.500 var
1 Ampere CT Range ....................................................... −1.500 var to +1.500 var
Accuracy ......................................................................... ±1% at zero power factor
Energy Data Reporting
5 Ampere CT Range ....................................................... 1.000.000 kWh or 1.000.000 kvarhr
1 Ampere CT Range ....................................................... 1.000.000 kWh or 1.000.000 kvarhr
Units of Measure ............................................................. kilo, mega, giga
Rollover Value of Registers ............................................ 1.000.000 kWh or 1.000.000 kvarhr
Accuracy ......................................................................... ±1% at unity power factor
24 Overexcitation Protection
Pickup
Setting Range ................................................................. 0.5 - 6V/Hz
Time Delay
Delay Time ...................................................................... Inverse Squared Curve
( )2
T T 1 M
D T
−
=
TT
= Time Trip
DT
= Time Dial, Trip
V/Hz Pickup
V/Hz Actual M=
25 Sync-Check Protection
Settings
Delta Phase Angle
Setting Range ................................................................. 1 to 99°
Accuracy ......................................................................... ±0.5°
Delta Voltage Magnitude
Setting Range ................................................................. 1 to 20 V
Accuracy ......................................................................... ±2% or ±1 V, whichever is greater
Delta Frequency
Setting Range ................................................................. 0.01 to 0.50 Hz
Accuracy ......................................................................... ±0.01 Hz
27P Phase Undervoltage Protection
Pickup
Setting Range ................................................................. 10 to 300 V
Accuracy ......................................................................... ±2% of setting or ±1 V, whichever is greater
Dropout/Pickup Ratio ...................................................... 102%
Time Delay
Setting Range ................................................................. 0.05 to 600 s
Accuracy ......................................................................... ±0.5% or +3.6/–1.9 cycles, whichever is greater
27X Auxiliary Undervoltage Protection
Pickup
Setting Range ................................................................. 1 to 150 V
Accuracy ......................................................................... ±2% of setting or ±1 V, whichever is greater
Dropout/Pickup Ratio ...................................................... 102%
Time Delay
Setting Range ................................................................. 0.05 to 600 s
Accuracy ......................................................................... ±0.5% or ±1 cycle, whichever is greater
40Q Loss of Excitation Protection
Pickup
5 Ampere CT Setting Range .......................................... 1 to 6.000 vars, 3-phase
1 Ampere CT Setting Range .......................................... 1 to 1.200 vars, 3-phase
Accuracy ......................................................................... ±3%
Time Delay
Setting Range ................................................................. 0.05 to 600 s
Accuracy ......................................................................... ±0.5% or ±3 cycles, whichever is greater
47 Negative-Sequence Overvoltage Protection
Pickup
Setting Range ................................................................. 1.0 to 300 VL-N
Accuracy ........................................................................ ±2% of setting or ±1 V, whichever is greater
Dropout/Pickup Ratio ...................................................... 98%
Time Delay
Setting Range ................................................................. 0.050 to 600 s
Accuracy ......................................................................... ±0.5% or ±1 cycle, whichever is greater
50T Instantaneous Overcurrent Protection
Pickup
5 Ampere CT Setting Range .......................................... 0.5 to 150 A
1 Ampere CT Setting Range .......................................... 0.1 to 30 A
Dropout/Pickup Ratio ...................................................... 95%
Accuracy
5 Ampere CT .................................................................. ±2% or ±50 mA, whichever is greater
1 Ampere CT .................................................................. ±2% or ±10 mA, whichever is greater
Time Delay
Setting Range ................................................................. 0 to 60 s
Accuracy
±0.5% or ±½ cycle, whichever is greater, plus trip time for instantaneous response (0.0 setting) ∗
∗ Trip Time for 0.0 Delay Setting
2¼ cycles maximum for currents ≥ 5 times the pickup setting. Three cycles maximum for a current of
1.5 times pickup. Four cycles maximum for a current of 1.05 times the pickup setting.
50BF Breaker Failure Protection
Pickup
Setting Range ................................................................. Fixed at 0.5 A for 5 A unit, 0.1 A for 1 A unit
Accuracy
5 Ampere CT .................................................................. ±2% or ±50 mA, whichever is greater
1 Ampere CT .................................................................. ±2% or ±10 mA, whichever is greater
Time Delay
Setting Range ................................................................. 50 to 999 ms
Accuracy ......................................................................... ±0.5% or +1¼, −½ cycles, whichever is greater
Reset Time ..................................................................... Within 1¼ cycles of the current being removed