Hirschmann EAGLE30-04022O6TT999SCCY9HSE3F Industrial Firewall Router Switch
❤ Add to collection

Hirschmann EAGLE30-04022O6TT999SCCY9HSE3F Industrial Firewall Router Switch

Hirschmann EAGLE30-04022O6TT999SCCY9HSE3F Industrial Firewall Router Switch

8690.00
¥7150.00
¥7150.00
¥7150.00
Weight:2.000KG
Description

Hirschmann EAGLE30-04022O6TT999SCCY9HSE3F Industrial Firewall Router Switch


Hirschmann EAGLE30-04022O6TT999SCCY9HSE3F Industrial Firewall Router Switch

Product: EAGLE30-04022O6TT999TCCY9HSE3F

Configurator: EAGLE30-04022O6TT999TCCY9HSE3F

Configurator Description

The advanced security functionality of the Hirschmann Security Operating System (HiSecOS), paired with these multiport industrial firewalls, creates a solution

capable of securing and protecting an entire industrial network.

Technical Specifications

Product description

Type Product code: EAGLE30-04022O6TT999TCCY9HSE3FXX.X

Description Industrial firewall and security router, DIN rail mounted, fanless design. Fast Ethernet, Gigabit Uplink type. 2 x SHDSL WAN ports

Part Number 942058001

Port Type and Quantity 6 ports in total; Ethernet Ports: 2 x SFP slots (100/1000 Mbit/s); 4 x 10/100BASE TX / RJ45

More Interfaces

V.24 interface 1 x RJ11 socket

SD-card slot 1 x SD card slot to connect the auto configuration adapter ACA31

USB interface 1 x USB to connect auto-configuration adapter ACA22-USB

Digital Input 1 x plug-in terminal block, 2-pin

Power Supply 2 x plug-in terminal block, 2-pin

Signaling contact 1 x plug-in terminal block, 2-pin

Network size - length of cable

Twisted pair (TP) 0-100 m

Single mode fiber (SM) 9/125 µm see SFP fiber module M-SFP-xx / M-Fast SFP-xx

Single mode fiber (LH) 9/125 µm

(long haul transceiver) see SFP fiber module M-SFP-xx / M-Fast SFP-xx

Multimode fiber (MM) 50/125 µm see SFP fiber module M-SFP-xx / M-Fast SFP-xx

Multimode fiber (MM) 62.5/125 µm see SFP fiber module M-SFP-xx / M-Fast SFP-xx

Network size - cascadibility

Line - / star topology any

Power requirements

Operating Voltage 2 x 24/36/48 VDC (18 -60VDC)

Power Consumption 14 W

Power output in BTU (IT)/h 48

Security features

Multipoint VPN IPSec VPN

Deep Packet Inspection N/A

Stateful inspection firewall Firewall rules (incoming/outgoing, management); DoS prevention

Software

Redundancy VRRP (Virtual Router Redundancy Protocol), VRRP Tracking

Management SNMPv3; SSH2/SFTP/SCP; HTTP; HTTPS; V.24 CLI; SNMPv1/2. Traps; local and central user management (RADIUS); HiDiscovery; Industrial HiVision; HiView; ; Dual

Software Image Support; LLDP (802.1AB);

Diagnostics LEDs (power, link status, data, status, ACA, RM); signal contact (DC 24 V / 1 A); logfile; syslog; configuration check; RMON (statistics); SFP diagnostics (temperature,

optical transmit and receive power); trap for changes and configuration saves; Counter for ACL Rules, Verbose syslog with traffic information

Configuration Command Line Interface (CLI); web interface; Auto Configuration Adapter (ACA22. ACA31); HiDiscovery; Industrial HiVision; Automatic Configuration Undo (roll-back);

Configuration Fingerprint; Text-based Configuration File (XML); CLI Scripting; Full-featured MIB Support;

Security Layer 3 and Layer 2 Access Control Lists (ACL); ACL flow based limiting; Audit trail; HTTPS; SSHv2; SFTP; SNMPv3; Management VLAN; Role based Access Control;

Remote Authentication via RADIUS; IEEE1686 compliant configuration possible; Ingress storm protection, Password change on first login

Time synchronisation Buffered Real Time Clock, NTP Client, NTP Server

Miscellaneous Support for WAN Interface SHDSL; Support for FE/GE Twisted Pair SFP; Wire speed port scan prevention; 8 QoS classes; port prioritization IEEE 802.1D/Q; VLAN IEEE

802.1Q, DHCP relay

Routing VLAN and port based routing; static routing; multinetting; IP masquerading; 1-to-1 NAT; port forwarding; Static and Dynamic ARP enteries; OSPFv2; Static Route Tracking

Ambient conditions

Operating temperature-40-+75 °C

Note IEC 60068-2-2 Dry Heat Test +85°C 16 Hours

Minimum Storage Temperature-40-+85 °C

Relative humidity (non-condensing) 10-95 %

Mechanical construction

Dimensions (WxHxD) 98 x 164 x 120mm

Weight 1500 g

Mount Type DIN Rail

IP Protection Rating IP20

Mechanical stability

IEC 60068-2-6 vibration 1 mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min.; 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min

IEC 60068-2-27 shock 15 g, 11 ms duration, 18 shocks

EMC interference immunity

EN 61000-4-2 electrostatic

discharge (ESD) 8 kV contact discharge, 15 kV air discharge

EN 61000-4-3 electromagnetic field 35 V/m (80 - 3000 MHz); 1kHz, 80% AM

EN 61000-4-4 fast transients (burst) 4 kV power line, 4 kV data line

EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line); data line: 1 kV; IEEE1613: power line 5kV (line/earth)

EN 61000-4-6 Conducted Immunity 10 V (150 kHz-80 MHz)

EN 61000-4-16 mains frequency

voltage 30 V, 50 Hz continous; 300 V, 50 Hz 1 s

EMC emitted immunity


  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units