DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
VIBRO-METER  IOC4G2    I/O interface card
❤ Add to collection

VIBRO-METER IOC4G2 I/O interface card

VIBRO-METER  IOC4G2    I/O interface card

¥8560.00
¥6542.00
¥6542.00
¥6542.00
Weight:2.000KG
Description

VIBRO-METER  IOC4G2    I/O interface card






Product Overview: Meggitt Vibro-Meter IOC4G2

The Vibro-Meter IOC4G2 is an Input/Output (I/O) rear card engineered specifically to pair with the MPC4G2 machinery protection card within the VM600 / VM600Mk2 series machinery protection system (MPS). Mounted in the back of a 19-inch VM600 rack (ABE04x / ABE056), the IOC4G2 acts as the physical interface between field measurement chains and the processing electronics.

Technical Specifications Table

ParameterSpecification Details
Manufacturer / BrandMeggitt / Vibro-Meter
Associated Processing CardMPC4G2 (or MPC4 series)
System Rack CompatibilityVM600 / VM600Mk2 (ABE04x, ABE056 Racks)
Channel Count4 Dynamic channels + 2 Auxiliary (speed/phase reference) channels
Field Terminal ConnectionScrew/screwless terminal strip connectors (48-point terminal block interface)
On-board Relays4 Alarm relays (Alert/Danger) + 1 Hardware Fault relay
Analog Current Outputs4–20 mA outputs (one per dynamic channel, software/jumper selectable)
Analog Voltage Outputs0–10 VDC proportional signals
Raw Signal OutputsBuffered raw sensor signal outputs (BNC or terminal strip) for external spectrum analysis
Protection FeaturesIntegrated surge protection and Electromagnetic Interference (EMI) filtering

Environmental Tolerance Conditions

Built for heavy industrial environments, the IOC4G2 maintains strict electrical and atmospheric protection standards:

Operating Temperature: $-25^circtext{C}$ to $+65^circtext{C}$ ($-13^circtext{F}$ to $+149^circtext{F}$)

Storage Temperature: $-40^circtext{C}$ to $+85^circtext{C}$ ($-40^circtext{F}$ to $+185^circtext{F}$)

Relative Humidity: $5%$ to $95%$ non-condensing

EMI/EMC Compliance: Meets EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Emissions)

Overvoltage Protection: Tested according to IEC 60255-5 electrical insulation/surge standards

Operating Instructions

1.Rear Rack Insertion:Align module in the rear rack slot opposite the MPC4G2.

Ensure the VM600 rack power supply is properly configured or isolated if hot-swapping is restricted by plant safety procedures. Align the IOC4G2 with the guide rails in the rear section of the rack directly behind the corresponding MPC4G2 card slot. Insert firmly until the multi-pin connector seats into the backplane.

2.Field Wiring Terminal Connection:Connect field transducers and external instrumentation。

Connect signal, common, and shield cables from proximity probes (IQS series), accelerometers, or velocity sensors into the designated screw terminal blocks. Connect output wires for 4–20 mA loops and relay contacts to the DCS/PLC terminal strips.

3.Shielding & Grounding Setup:Ground shield connection configuration。

Verify that cable shields are grounded at the IOC4G2 terminal shield points according to plant grounding guidelines to ensure full EMI protection and avoid earth loops.

4.System Software Mapping:Configure signal levels via VibroSight。

Power on the rack. Use VibroSight software to assign input sensitivity, voltage ranges, current loop zero/scale, and relay activation logic mapped through the front MPC4G2 card.

Fault Diagnosis

The IOC4G2 works passively and actively with the MPC4G2 to report field loop and card-level issues:

Fault SymptomProbable CauseCorrective Action
Channel "OK" Line Open / FaultSensor cable open/short circuit, incorrect gap voltage on proximity probe, or damaged sensor supply.Measure DC gap voltage across input terminals. Check field cabling continuity and sensor power supply voltage.
No 4–20 mA OutputOpen current loop, improper jumper configuration, or output DAC channel failure.Verify external loop load resistance ($le 500,Omega$). Check software configuration in VibroSight for proper output assignment.
Spurious Alarms / NoiseBroken cable shielding, missing ground connection, or strong local EMI.Inspect shield termination on the terminal strip. Ensure signal cables are separated from high-voltage power lines.
Backplane Communication ErrorImproper seating of the card, bent rear connector pins, or backplane fault.Power off slot, remove IOC4G2 card, inspect rear multi-pin connector for bent pins, and re-seat properly.

Related Models of the Same Series

The IOC4G2 belongs to the broader Meggitt Vibro-Meter VM600 machinery protection hardware family:

MPC4G2 / MPC4 / MPC4Mk2: Front-mounted machinery protection processing cards.

IOC4T: Legacy rear Input/Output card pair for MPC4 cards.

IOC4Mk2: Second-generation rear Input/Output card for VM600Mk2 series.

IOC16T / XIO16T: High-density 16-channel rear input/output cards for condition monitoring.

IOC8T: 8-channel temperature and process monitoring I/O card (pairs with AMC8).

RLC16 / IRC4: External relay expansion cards connected via the VM600 open-collector bus.

Storage Conditions

Proper storage practices ensure component reliability prior to field deployment:

Packaging: Keepsealed inside static-shielding (ESD) packaging with moisture absorber desiccant bags.

Storage Temperature: $-40^circtext{C}$ to $+85^circtext{C}$ ($-40^circtext{F}$ to $+185^circtext{F}$).

Relative Humidity: Less than $95%$ non-condensing.

Environment: Indoor cleanroom or climate-controlled warehouse free from corrosive chemical vapors, airborne dust, and high vibration exposure.



  • SAUTER AXT 201. 211: Thermal actuator for unit valves with stroke
  • SAUTER AXS 215S: Continuous actuator for unit valves, with stroke
  • SAUTER AXM 217S: Motorised actuator for unit valves with positioner
  • SAUTER AVM 321S, 322S: Valve actuator
  • SAUTER AVM234S: SUT valve actuator with positioner
  • SAUTER AVM 105. 115: Valve actuator
  • SAUTER AVF 234S: SUT valve actuator with spring return
  • SAUTER AVF124: Actuator with spring return
  • SAUTER AKM115SAF332: Smart Actuator for ball valve, BACnet/IP
  • SAUTER AKM115SA: Smart Actuator for ball valve
  • AKM 105S, 115S: Rotary actuator with SAUTER Universal
  • SAUTER AKM 105. 115: Rotary actuator for ball valve
  • SAUTER AVM 234S: SUT valve actuator with positioner
  • SELSEL-T401L Ultra-High-Speed Line Relay
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-787 Transformer Protection Relay
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL-487E Transformer Protection Relay
  • SEL-400G Advanced Generator Protection System
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700BT Motor Bus Transfer Relay
  • CTI 2500 Series® Slice Ethernet Remote I/O System
  • CTI 2500 Series® Compact Programmable Automation Control System
  • CTI 2500 Series® Classic Programmable Automation Control System
  • CTI 2500 Series® Bases
  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • EATON Instructions for the FP-5000
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671