DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
Vibro-MeterI/O interface card  IOCN Mk2 600-051
❤ Add to collection

Vibro-MeterI/O interface card IOCN Mk2 600-051

Vibro-MeterI/O interface card    IOCN Mk2    600-051

16574.00
¥14250.00
¥14250.00
¥14250.00
Weight:2.000KG
Description

Vibro-MeterI/O interface card    IOCN Mk2    600-051


I/O interface card    IOCN Mk2    600-051

VM600Mk2

CPUMMk2 + IOCNMk2

rack controller and

communications

interface module

KEY FEATURES AND BENEFITS

• VibroSight ® compatible hardware from the

vibro-meter ® product line

• VM600Mk2 (second generation)

rack controller and communications interface

module

• VM600Mk2 module data aggregation, processing

and sharing

• Industry standard fieldbus communications

interfaces: Modbus TCP and PROFIBUS DP

• Mathematical processing of data to be shared via

fieldbus

• System/module status (health) information

available via fieldbus

• Front-panel alarm reset (AR) button

• VM600Mk2 rack (CPUMMk2) security with a

removable key

• Two system Ethernet connections and two

fieldbus connections can run simultaneously

• Module-level communications redundancy with

two fieldbuses per module: Ethernet

and/or serial

• Rack-level communications redundancy with two

modules per rack (module redundancy)

KEY BENEFITS AND FEATURES (cont’d)

• Two output relays to signal system statuses

and alarms

• CPUMMk2 +  IOCNMk2 module diagnostic logs

available via the VibroSight ® software

• Live insertion and removal of modules

(hot-swappable)

• Gigabit (1 Gbps) system Ethernet

communication

• Front-panel status indicators (LEDs)

• Compatible with later VM600 system racks

(ABE04x) with I2C interface (VME utility bus)

DESCRIPTION (continued)

LEDs on the front panel of the CPUMMk2 module

(front of VM600Mk2 rack) indicate the mode of

operation and status of the CPUMMk2 + IOCNMk2

module, and the status of its system Ethernet and

fieldbus communications.

IOCNMk2 module

The IOCNMk2 module acts as a signal and

communications interface for the CPUMMk2 module.

It also protects all inputs against electromagnetic

interference (EMI) and signal surges to meet

electromagnetic compatibility (EMC) standards.

LEDs on the front panel of the IOCNMk2 module (rear

of VM600Mk2 rack) indicate the status of its system

Ethernet and fieldbus communications.

Fieldbus communications

The CPUMMk2 + IOCNMk2 module has two fieldbus

interfaces (ports), FIELDBUS1 and FIELDBUS2.

available on the IOCNMk2 module (rear of VM600Mk2

rack).

The fieldbus ports allow the CPUMMk2 module to act

as a data communications gateway between a

VM600Mk2 rack and external devices that use

fieldbus networks. In order to do this, the CPUMMk2

acts as a fieldbus server (slave) device that obtains

data from the modules in the VM600Mk2 rack

(MPC4Mk2 and XMx16 modules, and the CPUMMk2

module itself) to share with fieldbus client (master)

devices such as a DCS or PLC via one of the

CPUMMk2 + IOCNMk2 module’s fieldbus interfaces:

Modbus TCP and/or PROFIBUS DP.

Each fieldbus port, FIELDBUS1 and FIELDBUS2.

consists of two connectors, one for serial-based

fieldbus standards and one for Ethernet-based. Both

fieldbus ports can be active at the same time but only

one connector can be used per interface/port

(that is, connector J1 or J2 for FIELDBUS1. and

connector J4 or J5 for FIELDBUS2).

In addition, the system Ethernet ports support

Modbus TCP, which also allow the CPUMMk2 module

to share data from the other modules in the

VM600Mk2 rack.

The data to be shared by fieldbus can be

mathematically processed before it is shared and the

results of “data freeze” detection can also be shared

via fieldbus (defined by the fieldbus configuration

file)

VM600Mk2 rack (CPUMMk2) security

The CPUMMk2 module supports features that can be

used to limit the functionality of a VM600Mk2 rack’s

machinery protection system (MPS) that is available

via the system Ethernet connections of the

CPUMMk2 + IOCNMk2 module. Enabling VM600Mk2

rack (CPUMMk2) security helps to reduce the

possibility of interference in the machinery protection

function of the rack itself and in the machinery being

monitored. Accordingly, CPUMMk2 rack security

makes it easier for operators to comply with

international security/critical infrastructure

regulations.

A security key lock on the front panel of the CPUMMk2

module is used to enable or disable VM600Mk2 rack

security as required. With security enabled, the

CPUMMk2 module will prevent (block) certain system

operations such as the uploading of configurations

and the sending of Modbus commands.

Relays

The CPUMMk2 + IOCNMk2 module includes two

output relays to remotely indicate system status and

alarm information. Each of the relays can be mapped

to any Modbus bit variable and are typically used to

signal a fault or a problem detected by a common

alarm, such as communication status or rack status.


  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines