DCS; Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
Motorola MPC2004  BurstRAM™ Secondary Cache Module
❤ Add to collection

Motorola MPC2004 BurstRAM™ Secondary Cache Module

Motorola MPC2004  BurstRAM™ Secondary Cache Module

47610.00
¥45120.00
¥45120.00
¥45120.00
Weight:2.000KG
Description

Motorola MPC2004  BurstRAM™ Secondary Cache Module


Motorola MPC2004 | BurstRAM™ Secondary Cache Module

The Motorola MPC2004 is a specialized, high-performance 256KB BurstRAM™ secondary (L2) cache module.

It was engineered specifically for PowerPC™ platforms (PReP and CHRP architectures) to provide high-speed, burstable data access for the PowerPC 60x microprocessor family.

This module is essential for optimizing system throughput by reducing memory latency in professional workstations and embedded industrial controllers.

Technical Parameter Table

ParameterSpecification
Memory Capacity256 KB
Configuration32K x 72-bit (includes parity/ECC support)
Memory TypeSynchronous Fast Static RAM (BurstRAM)
Interface182-pin DIMM (Card Edge)
Clock RateUp to 66 MHz
Access Time9 ns (Data RAM) / 10 ns (Tag RAM match)
Voltage SupplyDual Voltage: 3.3V (I/O) and 5V (Core)
ArchitecturePReP / CHRP Compliant

Product Advantages and Features

PowerPC Optimization: Tailored to match the burst protocols of the PowerPC 60x bus, ensuring seamless "flow-through" data I/O.

Burst Mode Support: Features an on-chip burst counter that allows the module to handle rapid-fire data requests without constant address cycles.

Error Correction Ready: The 72-bit wide architecture provides the extra bits required for parity or ECC (Error Correction Code) to maintain data integrity.

Low Loading Design: Utilizes multiple clock pins to reduce electrical loading on the system bus, preserving signal quality at higher frequencies.

Rugged FR4 Construction: Built on high-quality, multilayer FR4 printed wiring boards with dedicated power and ground planes for superior noise immunity.

Application Cases

Industrial Embedded Computers: Used in high-end VMEbus single-board computers (SBCs) to accelerate real-time processing tasks.

Legacy Workstations: Serving as a critical cache upgrade for PowerPC-based desktop systems running AIX or early Windows NT for PowerPC.

Automation Controllers: Integrated into complex DCS (Distributed Control Systems) where high-speed logic and data pre-fetching are required.

Network Infrastructure: Used in mid-range routing and switching equipment that utilizes the PowerPC architecture for control plane management.

Other Models in the Same Series

The MPC200x family offers a clear upgrade path based on capacity and speed:

MPC2005: 512KB variant (64K x 72 bits).

MPC2006: 1MB Synchronous variant for high-demand CHRP platforms.

MPC2007 / MPC2009: Asynchronous cache module versions (256KB and 1MB).

MPC2104 / MPC2105: 3.3V-only versions for newer, low-power system designs.

Installation and Maintenance

Installation: Align the 182-pin module with the DIMM socket on the motherboard or carrier card. Ensure the module is fully seated until the retaining clips snap into place.

Voltage Verification: Critical: This module requires both 3.3V and 5V power rails. Verify that your system backplane or motherboard supports this dual-voltage configuration before installation.

Electrostatic Safety: Always handle the module by its edges and use an ESD-safe wrist strap. The high-speed SRAM chips are extremely sensitive to static discharge.

Diagnostics: Most Motorola VME systems (like the MVME series) include "Power-Up Self-Test" (PUST) firmware that will automatically detect and test the MPC2004 cache during boot-up.

Unique Product Description

The Motorola MPC2004 represents a bridge to the era of high-speed RISC computing.

It is more than just a memory stick; it is a precision-timed "acceleration engine" for the PowerPC ecosystem.

By offloading the most frequent memory requests to this 9ns module, systems can achieve deterministic performance that modern, generic RAM cannot replicate.

For engineers and technicians maintaining mission-critical legacy infrastructure, the MPC2004 remains a vital component for ensuring system stability and speed.


  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management Simplifying Optical Networks
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • Ethernet Modules EI 802F ABB
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • ABB AC 800F Controller Redundancy
  • ABB Freelance800F AC800F Data Sheet
  • ABB Compact control system replaces PLCs using AC 700F
  • ABB Triguard SC300E MSR04XI