DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
MOTOROLA  MVME162-223   Embedded Controller
❤ Add to collection

MOTOROLA MVME162-223 Embedded Controller

MOTOROLA  MVME162-223   Embedded Controller

28450.00
¥23580.00
¥23580.00
¥23580.00
Weight:2.000KG
Description

MOTOROLA  MVME162-223   Embedded Controller


MVME162

Embedded Controller

Features of the MVME162 include:

25MHz 32-bit Microprocessor: either an MC68LC040 Enhanced 32-bit

Microprocessor with 8KB of cache and MMU, or an optional 25MHz

MC68040 32-bit Microprocessor with 8KB of cache, MMU, and FPU

1MB, 4MB, or 8MB of shared Dynamic Random Access Memory (DRAM)

with programmable parity

512KB of Static Random Access Memory (SRAM) with battery backup

One JEDEC standard 32-pin PLCC EPROM socket (EPROMs may be

shipped separately from the MVME162)

1MB Flash memory: either one Intel 28F008SA (for older boards) or four

Intel 28F020s (for newer boards)

Four 32-bit programmable timers and programmable Watchdog Timer

(MCchip)

Two 32-bit programmable timers and programmable Watchdog Timer

(optional VMEchip2)

8K by 8 Non-Volatile Random Access Memory (NVRAM) and Time of

Day (TOD) clock with battery backup (Thompson MK48T08)

Input/Output– Two serial ports (one EIA-232-D DCE; one EIA-232-D or EIA-530

DCE/DTE) – Serial port controller (Zilog Z85230)– Optional Small Computer Systems Interface (SCSI) bus interface with

32-bit local bus burst Direct Memory Access (DMA) (NCR 53C710

controller)– Optional LAN Ethernet transceiver interface with 32-bit local bus

DMA (Intel 82596CA controller)– Four MVIP IndustryPack interfaces

VMEbus interface (VMEchip2)—non-VMEbus version optional– VMEbus system controller functions– VMEbus interface to local bus (A24/A32. D8/D16/D32

(D8/D16/D32/D64BLT) (BLT = Block Transfer)– Local bus to VMEbus interface (A16/A24/A32. D8/D16/D32)– VMEbus interrupter

– VMEbus interrupt handler– Global CSR for interprocessor communications– DMA for fast local memory-VMEbus transfers (A16/A24/A32.

D16/D32[D16/D32/D64BLT])

Switches and Light-Emitting Diodes (LEDs)– Two pushbutton switches (ABORT and RESET)– Eight LEDs (FAIL, STAT, RUN, SCON, LAN, FUSE, SCSI, and VME)

Specifications

Table 1-2. MVME162 Specifications, lists the specifications for an MVME162

without IndustryPacks. The subsequent sections detail cooling requirements

and FCC compliance.

Cooling Requirements

The Motorola MVME162 Embedded Controller is specified, designed, and

tested to operate reliably with an incoming air temperature range from 0° to

55° C (32° to 131° F) with forced air cooling at a velocity typically achievable

by using a 100 CFM axial fan.  Temperature qualification is performed in a

standard Motorola VMEsystem 3000 chassis.  Twenty-five watt load boards

are inserted in two card slots, one on each side, adjacent to the board under

test, to simulate a high power density system configuration.  An assembly of

three axial fans, rated at 100 CFM per fan, is placed directly under the VME

card cage.  The incoming air temperature is measured between the fan

assembly and the card cage, where the incoming airstream first encounters the

controller under test.  Test software is executed as the controller is subjected to

ambient temperature variations.  Case temperatures of critical, high power

density integrated circuits are monitored to ensure component vendors

specifications are not exceeded.

While the exact amount of airflow required for cooling depends on the

ambient air temperature and the type, number, and location of boards and

other heat sources, adequate cooling can usually  be achieved with 10 CFM

and 490 LFM flowing over the controller.  Less airflow is required to cool the

controller in environments having lower maximum ambients.  Under more

favorable thermal conditions, it may be possible to operate the controller

reliably at higher than 55° C with increased airflow.  It is important to note that

there are several factors, in addition to the rated CFM of the air mover, which

determine the actual volume and speed of air flowing over the controller.

Special Considerations for Elevated Temperature Operation

The following information is for users whose applications for the MVME162

may subject it to high temperatures.

The MVME162 uses commercial grade devices.  Therefore, it can operate in an

environment with ambient air temperatures from 0° C to 70° C.  Several factors

influence the ambient temperature seen by components on the MVME162.

Among them are inlet air temperature; air flow characteristics; number, types,

and locations of IndustryPack (IP) modules; power dissipation of adjacent

boards in the system, etc.

A temperature profile of the MVME162-023 was developed in an MVME945

12-slot VME chassis.  This board was loaded with one GreenSpring IP-Dual

P/T module (position a) and three GreenSpring IP-488 modules (positions b,

c, and d).  One twenty-five-watt load board was installed adjacent to each side

of the board under test.  The exit air velocity was approximately 200 LFM

OPTIMATEOP-620
OPTO 22SNAP-AITM-2
OPTO 22SNAP-IDC5D
ORIENTALA4722-9215KM
ORIENTAL MOTOR2GK180K
OSRAM/DULUX
OTHERFLASH   SERIES 2
OVATION5X00070G04
OVATION5X00063G01
OVATION1C31157G02
Ovation1C31238H01
OVATION1B30035H01
OVATION1B30023H01



  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor