Motorola MVME3100  single-board
❤ Add to collection

Motorola MVME3100 single-board

Motorola MVME3100  single-board

31450.00
¥27510.00
¥27510.00
¥27510.00
Weight:2.000KG
Description

Motorola MVME3100  single-board


MVME3100

DATA SHEET

The MVME3100 single-board

computer (SBC) gives additional

performance while protecting

your investment

System-on-chip NXP MPC8540 with

PowerPC® e500 processor core, integrated

memory controller, DMA engine, PCI-X

interface, Ethernet and local I/O

Two Gigabit Ethernet ports plus an

additional 10/100BaseTX port

Up to 512MB of DDR333 ECC memory

USB 2.0 and Serial ATA controllers for

integrating cost-effective peripherals

2eSST VMEbus protocol offering

interoperability with products such as the

MVME6100 at higher bandwidths

Dual 33/66/100MHz PMC-X sites for

expansion via industry standard modules,

support for processor PMCs and PMCspan

MVME721 direct-connect rear transition

module (RTM) for I/O routing through rear of

compact VMEbus chassis

NXP® MPC8540 VME SBC

The SMART Embedded Computing MVME3100. featuring the system-on-chip NXP MPC8540

processor, offers a growth path for VMEbus customers with applications on the previous

generation of VME, specifically the MPC8240 and similar (MPC603 family) processors.

The system-on-chip implementation offers power/thermal, reliability, and lifecycle advantages

not typically found in alternative architectures. The faster processor and 2eSST VMEbus

interface combine to offer significant performance improvement.

OEMs of industrial, medical, and defense/aerospace VMEbus platforms can now add

performance and features for competitive advantage while still protecting their fundamental

investment in VMEbus and related technologies. Customers can keep their VMEbus

infrastructure (chassis, backplanes, and other VMEbus and PMC boards) while improving

performance and extending the lifecycle. Also, the extended lifecycle of SMART EC computing

products helps reduce churns in development and support efforts resulting from frequent

product changes.

New cost-effective peripherals can be integrated easily using USB and Serial ATA interfaces.

SATA represents a significant cost reduction opportunity from older SCSI technology, with

generally lower drive pricing for equivalent capacity

Overview

VMEBUS 2ESST PERFORMANCE

The 2eSST protocol offers an available VME bus bandwidth of

up to 320MB/s, an increase of up to 8x over VME64. while

maintaining backward compatibility with VME64 and VME32.

The combination of the latest Texas Instruments VMEbus

transceivers and the Tundra Tsi148 VMEbus bridge’s legacy

protocol support allows customers to integrate the MVME3100

series into their existing infrastructure providing backward

compatibility and thereby preserving their investment in existing

VMEbus boards, backplanes, chassis and software.

BALANCED PERFORMANCE

The MVME3100 series provides more than just faster VMEbus

transfer rates; it provides balanced performance from the

processor, memory subsystem, local buses and I/O subsystems.

This coupled with a wealth of I/O interfaces make the

MVME3100 series ideal for use as an application-specific

compute blade, or an intelligent I/O blade/carrier. The NXP

MPC8540 system-on-chip (SoC) processor, running at speeds up to

833 MHz, is well-suited for I/O and data-intensive applications.

The integrated SoC design creates an I/O intensive state-of-the

art package that combines a low power processing core and

on-chip L2 cache with integrated controllers for memory, PCI-X,

DMA , Ethernet and local device I/O. The on-chip PCI-X bus and a

166 MHz DDR memory bus are well matched to the processor.

To ensure that the MVME3100 series can handle the 320MB/s

data rates of 2eSST, the Tsi148 VMEbus interface chip is directly

connected to the integrated PCI-X bus at 66 MHz. A secondary

PCI-X bus has dual PMC-X sites—each site supports PMC or

PMC-X cards supporting PCI bus speeds from 33 to 100 MHz.

The MVME3100 also offers dual Gigabit Ethernet interfaces, a

10/100 interface, USB 2.0. dual Serial ATA ports, and five (5)

RS232 serial connections. All of this adds up to a set of well

balanced subsystems offering unparalleled performance.

Backward Compatibility

The MVME3100 series continues the direction of providing a

migration path from SMART EC’s embedded controllers such as

the MVME16x, MVME17x, MVME2300/MVME2400. and from

SMART EC SBCs such as the MVME2600/2700 to a single

platform. The MVME3100 series, like the MVME5100. MVME5500.

and MVME6100 series, merged the best features of SMART EC’s

embedded controllers and SBCs enabling OEMs to support

varying I/O requirements with the same base platform, simplifying

part number maintenance, technical expertise requirements,

and sparing.

The MVME3100 series offers customers an alternate migration

path from the 68 K, MVME2100. MVME2300. MVME2400.

MVME2600. MVME2700. and MVME5100 boards to allow them to

take advantage of features such as the integrated MPC8540 SoC

processor, DDR memory, Gigabit Ethernet, PCI-X, USB, SATA,

and 2eSST.

PCI EXPANSION

The MVME3100 has a 32/64-bit, 33 MHz PCI connection to

support PCI expansion carriers such as the SMART EC PMCspan.

TRANSITION MODULES

The MVME721 transition module provides industry standard

connector access to one 10/100/1000BaseTx port. All of these

are via RJ45 connectors. The MVME721 RTM is designed to

directly connect to the VME backplane in chassis’ with an 80 mm

deep rear-transition area.

Software Support

FIRMWARE MONITOR

The MVME3100 firmware (known as MOTLoad) is resident in the

MVME3100 flash and provides poweron self-test initialization and

operating system booting capabilities. In addition, it provides a

debugger interface similar to the time proven “BUG” interface on

previous VMEbus boards from SMART EC.

OPERATING SYSTEMS AND KERNELS

The MVME3100 series supports booting a variety of Linux

operating systems.

Specifications

PROCESSOR

• Microprocessor: NXP MPC8540 PowerQUICC III – PowerPC

e500 core

• Clock Frequency: 667 or 833 MHz

• On-chip L1 Cache (I/D): 32 K/32 K

• On-chip L2 Cache: 256 KB look-aside

SYSTEM CONTROLLER

• Integrated within MPC8540

MAIN MEMORY

• Type: Double data rate (DDR1) ECC SDRAM

• Speed: DDR333 (166 MHz)

• Capacity: Up to 512MB SO-DIMM

• Configurations: One single-bank module; 256MB or 512MB

FLASH MEMORY

• Type: Flash, on-board programmable

• Capacity: 64MB or 128MB soldered flash options

• Write Protection: Hardware via switch, software via register or

sector lock

NON-VOLATILE MEMORY

• Type: SEEPROM, on-board programmable

• Capacity: 128 KB (available for users), 8 KB baseboard Vital

Product Data (VPD)

VMEBUS INTERFACE

• Compliance: ANSI/VITA 1-1994 VME64 (IEEE STD 1014), ANSI/

VITA 1.1-1997 VME64 Extensions, VITA 1.5-199x 2eSST

• Controller: Tundra Tsi148 PCI-X to VMEbus bridge with support

for VME64 and 2eSST protocols

• DTB Master: A16. A24. A32. A64; D08-D64. SCT, BLT, MBLT,

2eVME, 2eSST

• DTB Slave: A16. A24. A32. A64; D08-D64. SCT, BLT, MBLT,

2eVME, 2eSST, UAT

• Arbiter: RR/PRI

• Interrupt Handler/Generator: IRQ 1-7/Any one of seven IRQs

• System Controller: Yes, switchable or auto detect

• Location Monitor: Two, LMA32

ETHERNET INTERFACES

Controller: MPC8540 Triple Speed (TSEC) and Fast (FEC)

Ethernet Controllers

Interface Speed: Two @ 10/100/1000 Mbps (TSEC),

one @ 10/100/Mbps (FEC)

Connector: One Gigabit Ethernet port routed to front panel

RJ-45. one Gigabit Ethernet port and one 10/100 port routed to

VMEbus P2 connector, pin out matching MVME721 RTM

Indicators: Link status/speed/activity


  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management Simplifying Optical Networks
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • Ethernet Modules EI 802F ABB
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • ABB AC 800F Controller Redundancy
  • ABB Freelance800F AC800F Data Sheet
  • ABB Compact control system replaces PLCs using AC 700F
  • ABB Triguard SC300E MSR04XI
  • ABB Control product - Soft starter PST/PSTB (Intelligent Type)