DCS; Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
MOTOROLA  MVME712M  Transition Module.
❤ Add to collection

MOTOROLA MVME712M Transition Module.

MOTOROLA  MVME712M  Transition Module.

28760.00
¥35415.00
¥35415.00
¥35415.00
Weight:2.000KG
Description

MOTOROLA  MVME712M  Transition Module.


MVME712M  Transition Module.

The modules are used as the interface between the following families of Motorola

VMEmodules, and their peripheral devices:

MVME147 MPU VMEmodule

MVME162 Embedded Controller

MVME167 Single Board Controller (SBC)

MVME177 Single Board Controller (SBC)

MVME1600 Single Board Computer (SBC)

MVME2600 Single Board Computer (SBC)

MVME2700 Single Board Computer (SBC)

MVME3600 VME Processor Module

MVME4600 VME Processor Module

This chapter provides general information about the MVME712M

Transition Module and the P2 adapter board, specifications, cooling

requirements, and FCC compliance.

Description

The MVME712M is an I/O transition module for Motorola’s MPU

VMEmodule, VME Processor Module, Embedded Controller, and Single

Board Computer (SBC) families of processor modules, referred to in this

manual as MVMExxxx.

The MVME712M is used as an interface between the processor module

and its peripheral devices. The purpose of this module is to provide rear

panel industry-standard connectors that simplify external customer cable

requirements.

The P2 adapter board and cables are supplied for interconnection between

the MVME712M and the MVMExxxx. The P2 adapter assembly routes the

I/O signals and grounds from the P2 connector on the chassis backplane,

at the VMEmodule MPU connection, to the MVME712M.

The MVME712M routes the signals to four serial ports, implemented with

four industry standard DB-25 connectors on its front panel. The serial ports

may be configured for EIA-232-D DTE or DCE through jumper

arrangements on the MVME712M.

The MVME712M front panel also has an Ethernet port, a SCSI port, and

a printer port. In addition, the MVME712M routes the EIA-232-D port 2

signals to an internal modem.

MVME712M Transition Module

The features of the MVME712M include:

Four 25-pin multiprotocol EIA-232-D serial ports

(through P2 adapter)

One independent printer port (through P2 adapter)

Small Computer Systems Interface (SCSI) shielded connector bus

interface (through P2 adapter) for connection to internal and

external devices

Green LED on module to indicate terminator power

Yellow LED on module to indicate transceiver power

SCSI terminating resistors mounted in sockets for end of cable or

middle of cable configuration

Modem connection on module

Radio Frequency Interference (RFI) protection on front panel

Electrostatic Discharge (ESD) protection on front panel

P2 Adapter Board

The MVME712M requires the use of the P2 adapter board. The features of

the P2 adapter board include:

A connector that permits SCSI cable connection to other SCSI

devices and/or to MVME712M through a flat ribbon cable

SCSI terminating resistors mounted in sockets, for end of cable or

middle of cable configuration

Terminator power developed on the P2 adapter from the

+5 Vdc on connector P2. and fused (1 A) on the P2 adapter

A connector that interfaces the EIA-232-D ports, printer port, SCSI,

and Ethernet signals to the MVME712M

he following table lists the general specifications for the MVME712M

Transition Module. The subsequent sections detail cooling requirements

and FCC compliance.

A complete functional description of the MVME712M appears in Chapter

Motorola VMEmodules are specified, designed, and tested to operate

reliably with an incoming air temperature range from 0 degrees C to 55

degrees C (32 degrees F to 131 degrees F) with forced air cooling.

Temperature qualification is performed in a standard Motorola

VMEsystem 1000 chassis. Twenty-five watt load boards are inserted in the

two card slots, one on each side, adjacent to the board under test to

simulate a high power density system configuration. An assembly of three

axial fans, rated at 71 CFM per fan, is placed directly under the MVME

card cage. The incoming air temperature is measured between the fan

assembly and the card cage where the incoming airstream first encounters

the module under test.

Test software is executed as the module is subjected to ambient

temperature variations. Case temperatures of critical, high power density

integrated circuits are monitored to ensure component vendors

specifications are not exceeded.

While the exact amount of airflow required for cooling depends on the

ambient air temperature and the type, number, and location of boards and

other heat sources, adequate cooling can usually be achieved with 5 CFM

flowing over the module. Less air flow is required to cool the module in

environments having lower maximum ambients.

Under more favorable thermal conditions it may be possible to operate the

module reliably at higher than 55 degrees C with increased air flow. It is

important to note that there are several factors, in addition to the rated

CFM of the air mover, which determine the actual volume of air flowing

over a module

The MVME712M Transition Module was tested in an FCC-compliant

chassis, and meets the requirements for Class A equipment. FCC

compliance was achieved under the following conditions:

Shielded cables on all external I/O ports

Cable shields connected to earth ground via metal shell connectors

bonded to a conductive module front panel

Conductive chassis rails connected to earth ground; this provides

the path for connecting shields to earth ground

Front panel screws properly tightened

For minimum RF emissions, it is essential that the conditions above be

implemented. Failure to do so could compromise the FCC compliance of

the equipment containing the modules.

NISH68-68-EP
NISCXI-1193
NI SBRIO-9627
NINI-9694
NIBCOWD2000
nikuni25KLD07Z-M
NMB-MAT2410ML-05W-B50
NMSCG6060/32-4TE1
NMSCG6565/64-2L/8TE
NOVELLUS02-113640-00
NOVOTRONND32-5610VS-001-000-00
NYQUISTIOB-80
OBERG INDUSTRIESF-DMDM-PM-110E
OCM44A737830-001R04
OEMAXNX-AI8C



  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management Simplifying Optical Networks
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • Ethernet Modules EI 802F ABB
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • ABB AC 800F Controller Redundancy
  • ABB Freelance800F AC800F Data Sheet
  • ABB Compact control system replaces PLCs using AC 700F
  • ABB Triguard SC300E MSR04XI
  • ABB Control product - Soft starter PST/PSTB (Intelligent Type)
  • ABB Automation System ABB Procontic T200