DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
ADLINK NuPRO-598 REV A1 INDUSTRIAL CONTROL MOTHERBOARD
❤ Add to collection

ADLINK NuPRO-598 REV A1 INDUSTRIAL CONTROL MOTHERBOARD

ADLINK NuPRO-598 REV A1 INDUSTRIAL CONTROL MOTHERBOARD

5970.00
¥3540.00
¥3540.00
¥3540.00
Weight:2.000KG
Description

ADLINK NuPRO-598 REV A1 INDUSTRIAL CONTROL MOTHERBOARD


ADLINK NuPRO-598 REV A1 INDUSTRIAL CONTROL MOTHERBOARD

Product Introduction / Overview

The ADLINK NuPRO-598 REV A1 is an industrial-grade full-size PICMG 1.0 single board computer (SBC) designed for mission-critical industrial automation, process control, legacy system upgrades, and high-reliability computing. 

Built to support Intel processors with a high-bandwidth system bus, the NuPRO-598 combines high processing performance with expansive legacy I/O flexibility.

Featuring an array of onboard serial interfaces, dual Ethernet ports, integrated graphics, and PCI/ISA backplane expansion capability, the NuPRO-598 REV A1 delivers continuous $24/7$ operational stability in demanding industrial environments.

Technical Table

ParameterSpecification
ManufacturerADLINK Technology
Model / Hardware RevisionNuPRO-598 / Revision A1
Form FactorPICMG 1.0 Full-Size Single Board Computer (SBC)
Processor SupportIntel LGA775 Core 2 Duo / Pentium 4 / Celeron processors
Front Side Bus (FSB)1066 / 800 / 533 MHz
ChipsetIntel Q965 / ICH8 or equivalent industrial chipset family
System MemoryDual-channel DDR2 DIMM slots (up to 4 GB max capacity)
Integrated GraphicsIntel Graphics Media Accelerator (GMA) with VGA output
Ethernet ControllersDual 10/100/1000 Mbps Gigabit Ethernet (RJ-45)
Storage Interfaces4× SATA II (3 Gb/s), 1× Ultra ATA/100 IDE interface
Expansion BusPICMG 1.0 (PCI & ISA bus signals via backplane connector)
Peripheral Ports6× USB 2.0, 2× RS-232 COM, 1× LPT Parallel, PS/2 Keyboard/Mouse
Watchdog TimerProgrammable 1–255 sec/min system reset / interrupt trigger

Environmental Tolerance Conditions

ParameterOperational & Environmental Limit
Operating Temperature0°C to +60°C (32°F to 140°F)
Operating Humidity10% to 90% RH (non-condensing @ 40°C)
Vibration Tolerance0.5 Grms, 5–500 Hz, random (operational)
Shock Resistance10 G peak acceleration, 11 ms duration, half-sine wave
EMC / Safety CertificationCE class A, FCC Class A certified

Operating Instructions

Pre-Installation & ESD Handling

Electrostatic Protection: Always wear a grounded ESD wrist strap before touching the motherboard or memory modules.

Backplane Insertion: Align the NuPRO-598 REV A1 with the guide rails of a PICMG 1.0 compliant passive backplane.

 Press firmly until the golden finger connectors seat completely into the PCI/ISA slots.

Power Connection: Verify that the backplane ATX or AT power supply wiring harness provides stable +3.3V, +5V, +12V, and -12V DC power lines.

Initial Configuration & System Boot

BIOS Access: Connect a PS/2 or USB keyboard and VGA display monitor. Power on the system and press the Del or F2 key during POST to enter the Award/AMI BIOS setup utility.

Storage Mode Setting: Set SATA mode to IDE or AHCI depending on whether your operating system is legacy (Windows XP/WES2009) or modern (Windows 7/10/Linux).

Watchdog Timer Configuration: Enable the onboard hardware watchdog timer in BIOS or via system software API to trigger an automatic reboot if the OS crashes.

Fault Diagnosis

Warning: Before performing hardware diagnostics, disconnect primary AC power from the industrial chassis enclosure.

Symptom / FaultPossible Root CauseDiagnostic & Corrective Action
System does not boot (No POST, Fans don't spin)Power supply failure or poor PICMG backplane seatingCheck backplane DC power voltages. Unseat and firmly re-seat the SBC in the PICMG slot.
Continuous Beeping during POSTMemory initialization failureRemove DDR2 RAM modules, clean contact pins with isopropyl alcohol, and test one module at a time.
System freezes or reboots under heavy loadCPU overheating or thermal paste degradationInspect CPU fan operation. Clean heatsink dust and replace thermal compound on the processor socket.
Ethernet LEDs remain OFF when cable connectedDriver mismatch or port speed negotiation issueVerify link LEDs on RJ-45 jack. Check BIOS for disabled onboard LAN controllers; update network drivers in OS.
Watchdog Timer triggers constant rebootsSoftware loop timeout or unhandled exceptionCheck application log files; ensure watchdog heartbeat pulse is periodically cleared by system control software.

Related Models of the Same Series

The NuPRO Series by ADLINK includes several PICMG 1.0 and PICMG 1.3 industrial single-board computers configured for different computing eras and slot architectures:

NuPRO-E42: PICMG 1.3 system host board supporting 8th/9th Gen Intel Core processors for modern high-performance control systems.

NuPRO-E315: PICMG 1.3 System Host Board (SHB) with LGA1150 socket supporting 4th Gen Intel Core i7/i5/i3 CPUs.

NuPRO-935A: Full-size PICMG 1.0 SBC supporting Intel Core 2 Duo and Quad processors with dual Gigabit LAN.

NuPRO-852: Legacy PICMG 1.0 board designed for Intel Pentium M / Celeron M processors, ideal for legacy ISA/PCI slot equipment.

NuPRO-730: Industrial PICMG 1.0 board equipped with Socket 370 / Pentium III architectures for classic industrial field retrofits.

Storage Conditions

To preserve electronic component integrity and prevent solder joint oxidation during long-term storage, adhere to the following environment requirements:

ConditionRecommended Storage Parameter
Storage Temperature-20°C to +80°C (-4°F to 176°F)
Storage Humidity5% to 95% RH (non-condensing)
Packaging ProtocolStore sealed inside moisture-barrier anti-static bags (ESD shielding packaging) with desiccant packs.
Shelf-Life PrecautionsMaintain atmospheric temperature control; avoid direct exposure to corrosive gases, dust, or moisture condensation.



  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications