GE Power Conversion P112-6052 Advanced Micro Controller (AMC2)






GE Power Conversion P112-6052 Advanced Micro Controller (AMC2)

1. Product Overview

The GE Power Conversion P112-6052 is a industrial-grade Advanced Micro Controller 2 (AMC2) embedded processor. Designed originally by Converteam (now GE Power Conversion), the P112-6052 serves as a core automation and communication processor in high-availability industrial systems.

It features an integrated 600 MHz Celeron-M CPU, 5 Ethernet communication ports, and 2 × Serial16+ expansion cards. This unit excels in multi-device industrial networks, dynamic positioning (DP) systems, medium-voltage drives, marine vessel automation, and distributed control systems (DCS) where high-density serial connectivity and fault-tolerant operation are critical.

2. Technical Parameter List

ParameterSpecification Details
ManufacturerGE Power Conversion / Converteam
Model / Ordering CodeP112-6052 (AMC2 Controller)
Processor (CPU)Intel Celeron-M @ 600 MHz (Standard AMC2 Processor)
System Memory256 MB DRAM
Storage256 MB CompactFlash (Solid-State Drive)
Input Power Supply24 V DC (±20% tolerance)
Power ConsumptionNominal ~0.9 A @ 24 V DC
Network Interfaces5 × Integrated RJ45 Ethernet ports
Onboard Serial Ports4 × RS-232 ports (3 available for custom user applications)
Serial Expansion2 × Serial16+ expansion boards (high-density multi-channel serial)
USB Ports2 × USB ports with Yamaichi industrial latch mechanism
Internal Hardware Expansion4 × PMC / PC104+ extension slots
Physical Dimensions234 mm (W) × 206 mm (H) × 120 mm (D)

3. Product Features & Core Advantages

High-Density Serial Connectivity: Equipped with dual Serial16+ expansion modules, providing substantial multi-channel serial connectivity to interface with navigation sensors, field devices, and legacy serial equipment.

Multi-Network Routing Capability: Features 5 independent Ethernet ports, enabling separated control subnetworks, redundant system host links, and fieldbus protocol translation.

Industrial Fanless Thermal Design: Operates efficiently without mechanical moving cooling fans, drastically reducing maintenance downtime caused by dust exposure or fan wear.

Solid-State Reliability: Flash memory storage (256 MB CompactFlash) protects system data and runtime firmware against high mechanical vibration and continuous physical movement.

Complete Replacement Kit Standard: Ordered as a pre-configured controller unit with basic firmware, simplifying spare parts sourcing and swap-out procedures.

4. AMC2 Series Model Classification

The GE AMC2 Series categorizes models based on processing capacity (600 MHz Celeron-M vs 1.40 GHz Pentium-M) and onboard fieldbus/serial expansions:

Model CodeCPU Clock SpeedNetwork / Expansion ConfigurationPrimary Application Target
P110-6052600 MHz (Celeron-M)5 × Ethernet Ports (Base Unit)Standard Base Industrial Control
P111-6052600 MHz (Celeron-M)5 × Ethernet Ports + 1 × Serial16+Medium Serial Fieldbus Networks
P112-6052600 MHz (Celeron-M)5 × Ethernet Ports + 2 × Serial16+High-Density Serial Marine & DCS Control
P110-60531.40 GHz (Pentium-M)5 × Ethernet Ports (Base Unit)Upgraded High-Performance Base Controller
P112-60531.40 GHz (Pentium-M)5 × Ethernet Ports + 2 × Serial16+High-Performance DP & Heavy Process Automation
P121-6052600 MHz (Celeron-M)5 × Ethernet Ports + 1 × FIP Gateway CardWorldFIP Industrial Gateway
P122-6052600 MHz (Celeron-M)5 × Ethernet Ports + 2 × FIP Gateway CardsDual Redundant FIP Protocol Networks
P110-6152600 MHz (Celeron-M)5 × Ethernet Ports + 1 × Profibus MasterProfibus Master Automation Networks
P106-6052Standard Embedded CPU5 × Ethernet Ports (Windows XP Embedded)Embedded Industrial PC Applications

5. Environmental Tolerance Conditions

Operating Ambient Temperature: Rated up to 70 °C in a fanless passive cooling configuration.

Vibration & Mechanical Shock: Tested to 15 g shock rating compliant with IEC 61131-2 / IEC 1131-2 industrial controller standards.

Enclosure Protection: Requires installation inside an IP54 or better industrial metal cabinet.

Electromagnetic Compatibility (EMC): Heavy industrial immunity rating against electrical fast transients, power surges, and high-frequency noise interference.

6. Installation Method

Mechanical Mounting:

Mounting Style: Flange-mount panel assembly.

Secure the controller to a clean, flat, grounded metal backplate using 4 corner mounting screws.

Thermal Clearance: Maintain a minimum of 50 mm (2 inches) unobstructed clearance above and below the unit for natural convection air movement.

Electrical Connections:

Wire the 24 V DC power lines to the main terminal block, observing correct polarity ($+24text{ V}$, $0text{ V}$, and Earth Ground).

Fasten a thick, low-impedance Protective Earth (PE) strap from the chassis grounding stud directly to the cabinet ground bar.

Communication Cabling:

Insert RJ45 Ethernet network cables into designated LAN ports (LAN1–LAN5).

Connect serial cables to the RS-232 onboard ports or the Serial16+ interfaces, securing latching connectors where applicable.

7. Operating Instructions

Pre-Power Setup Check

Verify that the input supply voltage measures within 19.2 V DC to 28.8 V DC.

Ensure the CompactFlash memory card is fully seated in its card slot before applying power.

System Boot Sequence

Apply 24 V DC power. The internal power supply board initializes, followed by the system POST (Power-On Self-Test) routine.

Watch internal LED diagnostic indicators: steady power indication green LEDs confirm valid power supply; status LEDs indicate system firmware initialization.

Maintenance & Replacement Procedure

Hardware Identity Transfer: When replacing a faulty P112-6052 controller, transfer the physical hardware identity dongle / license key (if applicable) and the system CompactFlash card to the new controller unit.

Hot-Swap Caution: Always isolate power before inserting or removing PMC modules, serial expansion boards, or the CompactFlash card to prevent memory corruption or hardware damage.



  • CTI 2500 Series® Slice Ethernet Remote I/O System
  • CTI 2500 Series® Compact Programmable Automation Control System
  • CTI 2500 Series® Classic Programmable Automation Control System
  • CTI 2500 Series® Bases
  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • EATON Instructions for the FP-5000
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series 6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK PCI-8254/8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for