OMRON R88D-HT10 plc
OMRON R88D-HT10 plc
A clearer display that is easier to read.
Easy setup/operation and packed with
performance.
• A white LCD PV display with a height of approx. 18 mm for the
E5EC/E5EC-B and 25 mm for the E5AC improves visibility.
• High-speed sampling at 50 ms.
• With 48 x 96-mm Controllers, you can select between screw
terminal blocks or Push-In Plus terminal blocks to save wiring work.
• Short body with depth of only 60 mm. (Screw Terminal Blocks)
• Easy connections to a PLC with programless communications.
Use component communications to link Temperature Controllers
to each other.
• Tool ports are provided both on the top panel and the front panel.
Set up the Controller without wiring the power supply by
connecting to the computer with a Communications Conversion
Cable (sold separately). Setup is easy with the CX-Thermo (sold
separately)
.The options that can be selected depend on the type of control output.
*2.The control output cannot be used as a transfer output.
*3.A model with four auxiliary outputs must be selected.
Note:Draw-out-type models of the E5EC and E5AC are available. Ask your OMRON representative for details.
Heating and Cooling Control
Using Heating and Cooling Control

A Control Output Assignment
If there is no control output 2. an auxiliary output is used as the cooling control output.
If there is a control output 2. the two control outputs are used for heating and cooling.
(It does not matter which output is used for heating and which output is used for cooling.)
B Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
Option 004 and 014 cannot be selected if RX or QX is selected for the control output.
*2.Option 008. 010 and 011 cannot be selected if CX is selected for the control output.
*3.The control output cannot be used as a simple transfer output.
Heating and Cooling Control
Using Heating and Cooling Control
A Control Output Assignment
An auxiliary output is used as the cooling control output.
B Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics
| IS200EPSMG1A GE EX2100 Exciter Power Supply Module |
| IS200EPDMG1B GE Exciter Power Distribution Module |
| IS200EPCTG1A GE Exciter PT/CT Board |
| IS200EPBPG1A GE Exciter Power Backplane Board |
| IS200EMIOH1A GE Exciter Main I/O Board |
| IS200EMCSG1A GE Exciter Multibridge Conduction Sensor Card |
| IS200EISBH1A GE Exciter ISBus Board |
| IS200EHPAG2D GE High Voltage Pulse Amplifier Board |
| IS200EHPAG1D GE High Voltage Gate Pulse Amplifier |
| IS200EHFCH1A GE EX2100 Excitation Controller |
| IS200EGPAG1B GE Exciter Gate Pulse Amplifier Board |
| IS200EGDMH1A GE EX2100 Exciter Field Ground Detector Board |
| IS200EDCFG1B GE EDCF model and is an I/O terminal board |
| IS200ECTBG2A GE Exciter Contact Terminal Board |
| IS200ECTBG1A GE Exciter Contact Terminal Board |
| IS200EBKPG1C GE Backplane Control Board |
| IS200EACFG3B GE Exciter AC Feedback Board |
| IS200EACFG2B GE 1000V Exciter AC Feedback Board |
| IS200EACFG1B GE Exciter AC Feedback Board |
| IS200DSPXH1D GE Digital Signal Processor Control Board (DSPX) |
| SE4050E0C0 EMERSON S-series Horizontal Carriers |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|