DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
HIRSCHMANN RS20-1600M2M2SDAEHX09.0.00 Ethernet switch
❤ Add to collection

HIRSCHMANN RS20-1600M2M2SDAEHX09.0.00 Ethernet switch

HIRSCHMANN RS20-1600M2M2SDAEHX09.0.00 Ethernet switch

13560.00
¥11700.00
¥11700.00
¥11700.00
Weight:2.000KG
Description

HIRSCHMANN RS20-1600M2M2SDAEHX09.0.00 Ethernet switch


HIRSCHMANN RS20-1600M2M2SDAEHX09.0.00

Product Introduction / Overview

The Hirschmann RS20-1600M2M2SDAEHX09.0.00 is an industrial-grade, DIN-rail mounted managed Layer 2 Fast Ethernet switch from the OpenRail RS20 family (Belden/Hirschmann).

Engineered for high-density localized automation systems, this model provides a combination of 16 Fast Ethernet ports, including two multi-mode fiber ports with SC connectors for interference-free optical connectivity over medium distances.

Running on Hirschmann's enhanced software suite, it delivers comprehensive network management, high-availability redundancy, and robust cybersecurity features suitable for demanding industrial and utility networks.

Technical Parameter List

Parameter CategorySpecification Details
Model / Part CodeRS20-1600M2M2SDAEHX09.0.00
Order Code943 434-023 (Standard)
Total Port Count16 Ports total
Copper Ports14 x 10/100BASE-TX (RJ45 sockets)
Fiber Ports2 x 100BASE-FX Multi-Mode (SC Duplex connectors)
Fiber Distance / SpecsMulti-Mode 50/125 µm or 62.5/125 µm (Up to 5 km link budget)
Operating VoltageRedundant dual 12 V DC to 48 V DC inputs
Software LevelEnhanced Management (E) Layer 2 Features
Firmware ReleaseSoftware Release Version 09.0.00
Enclosure RatingIP20 metallic housing
Mounting Standard35 mm DIN Rail (EN 50022)
Diagnostics / LocalLED displays (Power status, Link/Data activity, Fault relay)

Product Features / Core Advantages

High-Density Hybrid Connectivity: Combines 14 RJ45 copper ports for localized field devices with 2 SC multi-mode optical ports for noise-immune fiber trunks back to core cabinets.

Industrial Redundancy Protocols: Supports Fast Ring Detection, Media Redundancy Protocol (MRP), and Rapid Spanning Tree Protocol (RSTP) for sub-20ms failover times in ring network topologies.

Dual Power Redundancy: Features dual DC power terminals with an integrated alarm signal contact to alert operators instantly in the event of power loop failure.

Granular Network Control: Complete administration via Web interface, Command Line (CLI), SNMP v1/v2c/v3. and HiVision integration.

Enhanced Management Security: Includes VLAN (802.1Q), IEEE 802.1X port-based access control, Quality of Service (QoS), and broadcast storm protection.

Model Classification (Breakdown of Model Structure)

RS20: Rail Switch series equipped exclusively with Fast Ethernet ports (10/100 Mbps).

16: Includes 16 total Fast Ethernet network interfaces.

00: Indicates no Gigabit uplink slots are present on this specific chassis.

M2M2: Interface 1 & 2 optics are 100BASE-FX Multi-Mode with SC connectors.

SD: Standard temperature range (0°C to +60°C) with standard DIN rail mounting.

AE: Enhanced Software Tier (offers extended Layer 2 switching & security features).

HX: Hirschmann Classic OpenRail Housing / Standard hardware variant.

09.0.00: Preset factory firmware software version.

Environmental Tolerance Conditions

Operating Temperature: 0°C to +60°C (Standard operational range).

Storage / Transport Temperature: -40°C to +70°C.

Relative Humidity: 10% to 95% (Non-condensing).

EMC Immunity: High immunity against electrostatic discharges (ESD) and surge voltages per EN 61000-6-2 standards.

Mechanical Stability: Certified high resistance against shock (15 g, 11 ms) and vibration (IEC 60068-2 standards).

Installation Method

DIN Rail Mounting: Hook the top clip onto the standard 35 mm DIN rail (EN 50022) and push the lower edge gently toward the rail until the mounting spring snaps firmly into place.

System Grounding: Fasten a low-impedance copper ground wire to the dedicated grounding terminal screw on the housing frame before attaching any network or power cabling.

Power Terminals: Wire primary and redundant DC power sources (12–48 V DC) to the terminal block connections (+24V / 0V for Power Input 1 and Power Input 2).

Cabling Connections:

Fiber: Remove protective dust plugs and insert multi-mode SC duplex fiber jumpers into the optical ports.

Copper: Insert standard RJ45 network cables until the retention tab clicks into position.

Operating Instructions

Power-On Sequence: Turn on power to either or both inputs; the system LED indicator will turn solid green once initialization finishes.

Initial Configuration & IP Setting:

Connect a configuration PC to one of the active RJ45 ports.

Use the Hirschmann HiDiscovery tool to locate the device's MAC address and assign a static management IP address.

Management Access: Access the switch by entering its assigned IP address into a web browser, sign in with default administrator credentials, and immediately change the password.

Configuration Backup: Use an optional Auto-Configuration Adapter (ACA21-USB or ACA11) plugged into the local console/USB port to store automatic system backups for rapid swapouts.

SEO Optimization & Indexing Guide

Note on Web Indexing: Standardizing structural technical schema helps web search engines crawl and parse technical catalog items cleanly.

To ensure this model number (RS20-1600M2M2SDAEHX09.0.00) gets discovered and indexed by Google quickly:

Title Tag & Meta Description:

Title Tag: HIRSCHMANN RS20-1600M2M2SDAEHX09.0.00 Managed Switch Datasheet

Meta Description: Technical specifications, model classification breakdown, environmental parameters, and installation guide for Hirschmann RS20-1600M2M2SDAEHX09.0.00 switch.

Structured Data (Schema.org): Embed Product JSON-LD markup on your product landing page:

JSON

{

"@context": "https://schema.org/",

"@type": "Product",

"name": "Hirschmann RS20-1600M2M2SDAEHX09.0.00",

"mpn": "RS20-1600M2M2SDAEHX09.0.00",

"sku": "943434023",

"brand": {

"@type": "Brand",

"name": "Hirschmann"

},

"description": "Industrial 16-Port Managed Ethernet Switch with 2 x Multi-Mode SC Fiber Ports"

}

URL Formatting: Ensure a clean URL structure, e.g., [https://yourdomain.com/hirschmann-rs20-1600m2m2sdaehx09-0-00](https://yourdomain.com/hirschmann-rs20-1600m2m2sdaehx09-0-00).

Google Search Console: Submit the live page URL using Google Search Console's URL Inspection Tool -> Request Indexing.



  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications