DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
Hirschmann RS20-1600S2T1SDAUHC Managed Industrial Switch
❤ Add to collection

Hirschmann RS20-1600S2T1SDAUHC Managed Industrial Switch

Hirschmann RS20-1600S2T1SDAUHC Managed Industrial Switch

11766.00
¥7450.00
¥7450.00
¥7450.00
Weight:2.000KG
Description

Hirschmann RS20-1600S2T1SDAUHC Managed Industrial Switch


Hirschmann RS20-1600S2T1SDAUHC Managed Industrial Switch

The Hirschmann RS20-1600S2T1SDAUHC (Belden Part Number: 943 434-999 custom configuration series) is a highly reliable, 18-port managed Fast Ethernet switch. Part of the proven OpenRail RS20 family, this switch is purpose-built for medium-to-large-scale industrial control systems where long-distance single-mode fiber uplinks are crucial.

Product Introduction / Overview

In sprawling industrial areas—such as marine ports, massive solar farms, or municipal water distribution grids—standard copper Ethernet links fail past the 100-meter mark. The RS20-1600S2T1SDAUHC addresses this physical limit by serving as a highly secure, fiber-enabled network node.

The switch features 16 Fast Ethernet RJ45 copper ports to handle localized connections like PLCs, variable frequency drives (VFDs), and HMIs. For the long-haul uplink back to the central control room, it features two Single-Mode SC fiber ports (supporting distances up to 32 km without signal loss). Operating under Hirschmann’s Layer 2 Professional (P) software and certified for ATEX Zone 2 explosive environments, it provides full-featured security, redundancy, and diagnostic capability directly in the field.

Technical Parameter List

Parameter / SpecificationDetails
Model CodeRS20-1600S2T1SDAUHC
Belden Order Code943 434-999 (Configured Model Series)
Total Physical Ports18 Ports
Copper Ports (Ports 3–18)16 x 10/100BASE-TX, RJ45 sockets, auto-crossing, auto-negotiation
Fiber Ports (Ports 1–2)2 x 100BASE-FX, Single-Mode SC connectors (up to 32 km range)
Software Level / TypeLayer 2 Professional (P)
Operating VoltageDual redundant inputs: $24text{ V DC}$ nominal ($9.6text{ V}$ to $60text{ V DC}$) or $24text{ V AC}$ ($18text{ V}$ to $30text{ V AC}$)
Power ConsumptionMaximum 12.1 W
Diagnostic Outputs1 x Signaling contact (dry relay, max. 1 A @ 24 V DC); RS-232 Console port (V.24 RJ11)
Dimensions (W x H x D)$110text{ mm} times 135text{ mm} times 111text{ mm}$ (Compact aluminum frame)
WeightApproximately 650 g

Product Features / Core Advantages

Long-Distance Single-Mode Uplinks: The two SC single-mode ports transmit data over distances up to 32 km (19.8 miles), offering superior noise immunity and lightning isolation between plant sections.

Rapid Network Self-Healing: Supports the Media Redundancy Protocol (MRP) and HIPER-Ring topologies, ensuring that if a fiber line is physically damaged, traffic recovery occurs in less than 20 ms.

Hardened Security Features: Integrated Layer 2 Professional software supports IEEE 802.1X network access control, IP/MAC access control lists (ACLs), port security based on MAC addresses, and encrypted configuration access (HTTPS/SSH).

Industrial-Grade Redundancy: Features dual power inputs (AC or DC) and a failure contact relay to alert the SCADA system instantly in the event of an external power drop or a vital link failure.

Model Classification (RS20 Code Decoder)

This code specifies the precise hardware build:

RS20 - 16 00 S2 T1 S D A U H C

| | | | | | | | | | |

[1] [2][3][4][5][6|7|8][9|10|11]

[1] RS20: Industrial Managed Fast Ethernet Switch.

[2] 16: 16 x Fast Ethernet copper ports ($10/100text{ Mbps}$).

[3] 00: 0 x Gigabit Ethernet ports.

[4] S2: Port 1 fiber interface: Single-Mode SC Fiber ($1300text{ nm}$ wavelength, standard power).

[5] T1: Port 2 fiber interface: Single-Mode SC Fiber (matching Port 1 for symmetric ring configurations).

[6. 7. 8] S D A: Standard temperature range ($0^circtext{C}$ to $+60^circtext{C}$), Dual redundant power supply ($9.6text{-}60text{V DC}$), Approvals (CE, FCC, cUL508).

[9. 10. 11] U H C: U (ATEX Zone 2 hazardous location approvals), H (Classic software version), C (v07.1.x / Classic Software Release).

Environmental Tolerance Conditions

Operating Temperature: $0^circtext{C}$ to $+60^circtext{C}$ ($32^circtext{F}$ to $140^circtext{F}$)

Storage/Transport Temperature: $-40^circtext{C}$ to $+70^circtext{C}$

Relative Humidity: 10% to 95% (completely non-condensing)

Ingress Protection Rating: IP20 (robust aluminum chassis acting as a passive heatsink)

Shock/Vibration Standards: IEC 60068-2-27 (shock), IEC 60068-2-6 (vibration)

Hazardous Area Certification: ATEX Zone 2 / Class I Div 2 (ISA 12.12.01) certified for safe operation in explosive atmospheres.

Installation Method

[DIN Rail Attachment Hook]

||

/

====|==== <-- Rest top groove on 35mm DIN rail

|

[ RS20 ]

|

====|==== <-- Push bottom in until metal latch clicks

Mounting: Hang the upper notch of the built-in metal DIN-rail attachment on the back of the housing over the top edge of a standard 35 mm DIN rail (EN 50022).

Locking Down: Push the bottom half of the switch body firmly toward the rail until the bottom spring-loaded metal clip snaps closed over the bottom rail edge.

PE Chassis Grounding: Connect the grounding terminal screw at the bottom front edge of the chassis to your cabinet's primary functional ground bus to shield the internal network processors from static and power surges.

Operating Instructions

1. Wiring the Interfaces

Copper Ports (Ports 3–16): Use standard Category 5e or better twisted-pair RJ45 cables. Auto-MDI/MDI-X automatically adjusts for patch or crossover cables.

Fiber Optic Ports (Ports 1–2): Pull off the plastic dust caps. Connect single-mode fiber optic patch cords with SC connectors. Ensure the Tx (transmitter) line on the switch connects to the Rx (receiver) line on the remote device.

2. Network Interface Access

Initial Boot: By default, the switch requests an IP address via DHCP or BOOTP. To set a static IP, connect to the RJ45 console port using an RJ11-to-DB9 cable (V.24 interface), or scan the local subnet using the Hirschmann HiDiscovery software utility.

Web Management: Enter the switch's IP address into a web browser. Log in with the default username admin and default password private (you will be prompted to update this on first login for cybersecurity compliance).


  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter