SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
SEL-3530-4
Real-Time Automation Controller (RTAC)
The SEL-3530-4 is a midlevel RTAC that offers complete and flexible system control, integrated security, unified logic, and reliability—all in a small form factor.
It is a 1U half-rack unit that can be configured with multiple mounting options, including rack, panel, surface, and DIN mounts.
The SEL-3530-4 is ideal for small to medium installations with space constraints and applications integrating data for up to 60 devices.

Client Protocols
CDC Type II
Courier
CP 2179
DNP3 Serial, DNP3 LAN/WAN
EtherNet/IP—Explicit Message Client*
File Transfer Protocol (FTP)/Secure FTP (SFTP)*
Flex Parse
IEC 60870-5-101/104
IEC 60870-5-103
IEC 61850 MMS and MMS Client File Services*,1
IEEE C37.118 Synchrophasors
LG 8979
Modbus RTU, Modbus TCP
OPC UA*,2
SEL Protocols
SES-92
Simple Network Management Protocol (SNMP)
Server Protocols
CDC Type II
DNP3 Serial, DNP3 LAN/WAN
EtherNet/IP—Implicit Message Adapter*
FTP/SFTP
IEC 60870-5-101/104
IEC 61850 MMS and MMS Server File Services*
IEEE C37.118 Synchrophasors
LG 8979
Modbus RTU, Modbus TCP
OPC UA*,2
SEL Protocols
SES-92
SNMP Agent
Peer-to-Peer Protocols
IEC 61850 GOOSE*
Network Global Variable List (NGVL)
SEL Mirrored Bits Communications
Field Bus Protocol
EtherCAT to SEL-2240 Axion I/O Modules*,3
*Optional feature.
1Not supported on the SEL-3505 and SEL-3505-3.
2Only supported on the SEL-3350 RTAC, SEL-3555. SEL-3560S, and SEL-3560E.
3Only supported on the SEL-3530-4. SEL-2241. SEL-3350 RTAC, SEL-3555. and 3560E. For the SEL-3555 and SEL-3560E to support EtherCAT, they should be configured to include the SEL-3390E4 expansion card.
Rugged Hardware—The RTAC is designed and tested to meet or exceed IEEE 1613 and protective relay specifications for harsh environments and to withstand vibration, electrical surges, fast transients, and extreme temperatures.
The SEL RTAC operates reliably, even in challenging environments. For added protection, you can order conformal coating to protect against harsh environments and airborne contaminants, such as hydrogen sulfide, chlorine, salt, and moisture.
Simple, Seamless Configuration—Quickly design an integrated automation system that includes protocol conversion, SCADA communications, IEC 61850 integration,
synchrophasors, time synchronization, data management, and programmable logic.
New automation tools are continuously being added to simplify complex applications, such as condition monitoring, disturbance fault recording, configuring SCADA point maps, and archiving and alarming for data changes.
See the acSELerator RTAC SEL-5033 Software manual for more information on our automation software extensions.
Extensive Protocol Support—Concentrate and manage data from new and legacy relays and other IEDs using our extensive set of protocols.
Standard SCADA protocols are included with the purchase of any RTAC, including DNP3. IEC 60870-101/104. Modbus, and many more.
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|