SEL SEL-5705 Synchrowave Reports
SEL-5705 Synchrowave Reports
Automated Meter Data and Power Quality Reporting Software
Visualize high-resolution power system data and generate reports using Synchrowave Reports.
This web-based software helps you better analyze, organize, and share the historical data you collect from SEL meters and other devices across your system.
It supports you in making planning, operating, and accounting decisions to improve efficiency and reduce costs.
Synchrowave Reports can be configured with report templates designed to support metering data analysis and power quality monitoring.
Synchrowave Reports can be licensed with a Meter Data option or a Power Quality option.
The Meter Data option offers report types that support data analysis through tables, static graphs, and dynamic charts.
The Power Quality option offers all Meter Data reports and adds IEEE 519 compliance reports. Both the Meter Data and Power Quality options can be bundled with SEL software for automated data collection

Visualize and Analyze Power System Data
Derive more insights out of the historical data you collect from meters or other power system devices.
Analyze long-term data trends or use interactive graphs to drill down and isolate events or time periods of interest.
Examine data in the Synchrowave Reports web interface or export data for further analysis.
Retrieve Reports on Demand or by Email
Generate reports on demand, or have them automatically delivered to your email inbox at 15-minute, hourly, daily, weekly, or monthly intervals. Choose between PDF or CSV file formats.
Simplify Access With Web-Based Software
Access Synchrowave Reports from any location, and simplify software licensing and maintenance.
Take advantage of security features that maintain data confidentiality, such as Transport Layer Security (TLS) encryption and Lightweight Directory Access Protocol (LDAP) authentication.
Optimize Your System With Meter Data Reports
Visualize and report on system-wide meter data, including voltage sag, swell, and interruption (VSSI) data; Load Data Profile (LDP) information; Sequential Events Recorder (SER) data; and water, air, gas, electricity, and steam (WAGES) consumption details.
Use meter data to validate usage patterns and identify areas for improvement, such as opportunities to avoid peak demand charges by moving overlapping electric processes to off-peak hours.
ITI (CBEMA) curves and detailed voltage event tables help you recognize power disturbance issues before they affect equipment.
Monitor Power Quality and Confirm Compliance
Easily monitor power quality and confirm compliance with IEEE Std 519. Standard for Harmonic Control in Electric Power Systems. Innovations in ac/dc and dc/ac power conversion have led to the growing adoption of technologies that increase harmonic distortion on distribution and transmission lines, which negatively affect neighboring loads and generation sources.
With Synchrowave Reports, you can monitor a single point or an entire power system to support compliance activities and help detect distortions that cause excess heat, efficiency loss, system capacity reduction, and other issues.
Device Overview Report
Visualize device status and measurement point names, locations, time zones, time offsets, and more. SER Report
Quickly identify the exact time of power loss events, settings changes, voltage disturbances, digital state changes, and meter access in a precise time-stamped summary report of device and system events.LDP Report
Aggregate LDP data from one or more measurement points, up to 16 distinct channels, including timed interval quantities like current, voltage, frequency, and power.
Refine data selection with an interactive graph that displays metering data for a specified time period. Analyze trends and inspect records from a metering point, device, or group that you select.
VSSI Summary and Detail Reports
View event summaries, including ITI categorization, with the VSSI Summary Report. Use the VSSI Detail Report to analyze events with detailed VSSI data (using variable sampling rate records) in tabular format.
Identify points of interest with 4 ms resolution. Interactive charts help determine the time, duration, severity, and location of power quality disturbances.Signals Report
Combine WAGES consumption from third-party pulse-output meters and convert pulses to engineering units using the scaling features of the Signals Report.
Interactive charts and tabular reports help you thoroughly analyze system-wide resource consumption.
IEEE 519 Compliance Report
Identify distortion at the point of common coupling that produces undesirable harmonics on the power system. Easily confirm compliance with IEEE 519. One-page summary reports document pass or fail information for voltage and current.
Summary reports also provide site information, including location, device type, and system configuration, to support asset management. Detailed reports combine summary report information with individual voltage and current harmonic values for each metering point, up to the 50th harmonic.
This granularity helps identify exact frequency ranges that cause harmonic distortion.