Omron V680-CA5D02-V2 Programmable Controller
Omron V680-CA5D02-V2 Programmable Controller
Use two Mounting Adapters, either on the top and bottom or on the right and left.
•Setup Tool ports are provided as standard feature. Use these ports to connect a computer to the Digital Temperature Controller. The E58
CIFQ2 USB-Serial Conversion Cable is required to connect to the port on the side panel. The E58-CIFQ2 USB-Serial Conversion Cable
and E58-CIFQ2-E Communications Conversion Cable are required to connect to the port on the bottom panel. (You cannot leave either
port connected constantly during operation.)
•To install the Temperature Controller, insert it into a square hole in a panel with a thickness of 1 to 8 mm, and then insert the enclosed
adapter so that it locks into the grooves on the top and bottom or on the left and right of the rear case.
•Tighten the two mounting screws on the top and bottom or on the right and left of the Mounting Adapters alternately little by little to main
tain a balance, and tighten them to a torque of between 0.29 and 0.39 N·m.
•When two or more Temperature Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable
operating temperature range given below.

Horizontal group mounting: −10 to 55°C
Vertical group mounting of two Controllers: −10 to 45°C
Vertical group mounting of three or more Controllers: −10 to 40°C
• If you use vertical group mounting, you cannot draw out the interior body of the Controller
To mount the Temperature Controller so
that it is waterproof, insert the Waterproof
Packing onto the Temperature Controller.
Group mounting does not allow waterproof
ing.
Thru-current (Io) vs. Output Voltage (Eo)
(Reference Values)
9
E54-CT3 or E54-CT3L
Maximum continuous heater current: 120 A (50/60 Hz)
(Maximum continuous heater current for an OMRON
Digital Temperature Controller is 50 A.)
Number of windings:
Winding resistance
Mounting Adapter
Y92F-53 (Two provided.)
Waterproof Packing
Y92S-P12
Draw-out Jig
Y92F-55
Terminal Covers
E53-COV27
One pair is provided with the Temperature
Controller. Order the Mounting Adapter
separately if it becomes lost or damaged
| 1420-V2-ENT Allen-Bradley Galvanic insulation with built-in CTs |
| 3BSC610044R1 SD811V1 AC800F power supply module |
| 330710-000-60-10-02-00 3300 XL 11 mm Proximity Probes |
| 330850-90-00 Bently Nevada 3300 XL 25 mm Proximitor Sensor |
| 3BHE039724R103E PPD513A10-454000 High-performance process control system ABB |
| 38HE023784R1023 PPD113B01-10-150000 High-performance process control system ABB |
| UNITROL 5000 ABB Excitation Systems for Medium and Large Synchronous Machines |
| SPER1B1C4 ABB Trip circuit Supervision Relay |
| EPSCPE100-ACAH GE CONTROLLER FIRMWARE RELEASE 10.17 |
| 3HAC046664-001 ABB Universal joint |
| 65UV5-1004ECEX FIREYE Integrated Flame Scanner with Internal Flame Relay |
| 10310/1/1 Honeywell Earth leakage detector (ELD) |
| 369-HI-0-M-0-0 GE motor management relay |
| CI854AK01 3BSE030220R1 ABB PROFIBUS-DP/V1 interface |
| 369-HI-R-M-0-0 GE Motor Management Relay |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|