DCS Industrial control system
NameDescriptionContent
NEW CENTER
Current Location:

EMERSONMVME6100 Single-Board Computer Programmer’s Reference Guide

From:EMERSON | Author:LIAO | Time :2025-08-20 | 745 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Safety Summary

The following general safety precautions must be observed during all phases of operation, service, and repair of

this equipment. Failure to comply with these precautions or with specific warnings elsewhere in this manual

could result in personal injury or damage to the equipment.

The safety precautions listed below represent warnings of certain dangers of which Motorola is aware. You, as

the user of the product, should follow these warnings and all other safety precautions necessary for the safe

operation of the equipment in your operating environment.

Ground the Instrument.

To minimize shock hazard, the equipment chassis and enclosure must be connected to an electrical ground. If the

equipment is supplied with a three-conductor AC power cable, the power cable must be plugged into an approved

three-contact electrical outlet, with the grounding wire (green/yellow) reliably connected to an electrical ground

(safety ground) at the power outlet. The power jack and mating plug of the power cable meet International

Electrotechnical Commission (IEC) safety standards and local electrical regulatory codes.

Do Not Operate in an Explosive Atmosphere.

Do not operate the equipment in any explosive atmosphere such as in the presence of flammable gases or fumes.

Operation of any electrical equipment in such an environment could result in an explosion and cause injury or

damage.

Keep Away From Live Circuits Inside the Equipment.

Operating personnel must not remove equipment covers. Only Factory Authorized Service Personnel or other

qualified service personnel may remove equipment covers for internal subassembly or component replacement

or any internal adjustment. Service personnel should not replace components with power cable connected. Under

certain conditions, dangerous voltages may exist even with the power cable removed. To avoid injuries, such

personnel should always disconnect power and discharge circuits before touching components.

Use Caution When Exposing or Handling a CRT.

Breakage of a Cathode-Ray Tube (CRT) causes a high-velocity scattering of glass fragments (implosion). To

prevent CRT implosion, do not handle the CRT and avoid rough handling or jarring of the equipment. Handling

of a CRT should be done only by qualified service personnel using approved safety mask and gloves.

Do Not Substitute Parts or Modify Equipment.

Do not install substitute parts or perform any unauthorized modification of the equipment. Contact your local

Motorola representative for service and repair to ensure that all safety features are maintained.

Observe Warnings in Manual.

Warnings, such as the example below, precede potentially dangerous procedures throughout this manual.

Instructions contained in the warnings must be followed. You should also employ all other safety precautions

which you deem necessary for the operation of the equipment in your operating environment.

Warning

Warning To prevent serious injury or death from dangerous voltages, use extreme 

caution when handling, testing, and adjusting this equipment and its 

components.

Flammability

All Motorola PWBs (printed wiring boards) are manufactured with a flammability rating 

of 94V-0 by UL-recognized manufacturers.

EMI Caution

!

Caution

Caution This equipment generates, uses and can radiate electromagnetic energy. It 

may cause or be susceptible to electromagnetic interference (EMI) if not 

installed and used with adequate EMI protection.

Lithium Battery Caution

This product contains a lithium battery to power the clock and calendar circuitry.

!

Caution

Caution Danger of explosion if battery is replaced incorrectly. Replace battery only 

with the same or equivalent type recommended by the equipment 

manufacturer. Dispose of used batteries according to the manufacturer’s 

instructions.

Attention

!

Caution Il y a danger d’explosion s’il y a remplacement incorrect de la batterie. 

Remplacer uniquement avec une batterie du même type ou d’un type 

équivalent recommandé par le constructeur. Mettre au rebut les batteries 

usagées conformément aux instructions du fabricant.

Vorsicht

!

Caution Explosionsgefahr bei unsachgemäßem Austausch der Batterie. Ersatz nur 

durch denselben oder einen vom Hersteller empfohlenen Typ. Entsorgung 

gebrauchter Batterien nach Angaben des Herstellers

CE Notice (European Community)

!

Warning

Warning This is a Class A product. In a domestic environment, this product may 

cause radio interference, in which case the user may be required to take 

adequate measures.

Motorola Computer Group products with the CE marking comply with the EMC Directive 

(89/336/EEC). Compliance with this directive implies conformity to the following 

European Norms:

EN55022 “Limits and Methods of Measurement of Radio Interference Characteristics 

of Information Technology Equipment”; this product tested to Equipment Class A

EN55024 “Information technology equipment—Immunity characteristics—Limits and 

methods of measurement”

Board products are tested in a representative system to show compliance with the above 

mentioned requirements. A proper installation in a CE-marked system will maintain the 

  • CTI 2500-ADP2-DISC Discrete Wiring Adapter for Series 500
  • CTI 2500-ADP1 Analog Wiring Adapter for Series 500
  • CTI 2500C-RADP-RS485 Remote Base Controller Adapter for Series 500
  • CTI 2500C-RADP-RBC Profibus RBC Adapter for Series 500
  • CTI 2500C-PADP-120V 120VAC 50W Power Supply for Series 500
  • CTI 2500-RADP RBC Adapter for Series 500
  • CTI 2500-R4500 520/530/DBC Adapter for Series 500 - MATURE
  • CTI 2500-PADP Power Supply Adapter for Series 500
  • CTI 2500-IADP I/O Adapter for Series 500
  • CTI 2500-VP15A-N4-W7 15" Flat-Panel PC with Windows® 7 Embedded
  • CTI 2500S-27-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 8DIO / 2UAI
  • CTI 2500S-23-1750 Slice I/O, Ethernet, RS232/485. 900MHz, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500S-27-1550 Slice I/O, RS232/485. 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1550 Slice I/O, RS232/485. 8DIO / 2UAI
  • CTI 2500S-23-1550 Slice I/O, RS232/485. 4DI / 4DO / 2UAI / 2AO
  • CTI 2500S-27-1050 Slice I/O, Ethernet, 2DIO / 4UAI / 2AI
  • CTI 2500S-26-1050 Slice I/O, Ethernet, 8DIO / 2UAI
  • CTI 2500S-23-1050 Slice I/O, Ethernet, 4DI / 4DO / 2UAI / 2AO
  • CTI 2500C-32F-CJC 32-Pin Field Wiring Connector with Cold Junction Compensation
  • CTI 2500C-32F 32-Pin Field Wiring Connector
  • CTI 2500C-8-TC Eight Thermocouple Inputs
  • CTI 2500C-8-RTD Eight RTD Inputs
  • CTI 2500C-8-RL-FC 8 Form-C Relay Outputs
  • CTI 2500C-8-IDO-24V 8 Isolated 24VDC Outputs
  • CTI 2500C-8-IDO-120V 8 Isolated 120VAC Outputs
  • CTI 2500C-16-DO-24V Sixteen 24VDC Digital Outputs
  • CTI 2500C-16-DO-120V Sixteen 120VAC Digital Outputs
  • CTI 500C-16-IDI-24V Sixteen Isolated 24V AC/DC Digital Inputs
  • CTI 2500C-16-IDI-120V Sixteen Isolated 120V AC/DC Digital Inputs
  • CTI 2500C-16-DIDO-SIM Sixteen Digital Input and Output SImulator
  • CTI 2500C-16-DI-24V Sixteen 24V AC/DC Digital Inputs
  • CTI 2500C-16-DI-120V Sixteen 120V AC/DC Digital Inputs
  • CTI 2500C-RBC-RS485 RS485 Remote Base Controller
  • CTI 2500C-RBC-PRF Profibus Remote Base Controller
  • CTI 2500C-PS-24V-35 35-Watt DC Power Supply
  • CTI 2500C-PS-120V-35 35-Watt AC Power Supply
  • CTI 2500C-R8 Eight-Slot Base
  • CTI 2500C-R4 Four-Slot Base
  • CTI 2500C-R16 Sixteen-Slot Base
  • CTI 2500C-2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2500C-J750 Compact Janus PAC with 3MB Project Memory
  • CTI 2500C-C300 CPU with 512K User Memory
  • CTI 2500C-C200 CPU with 256K User Memory
  • CTI 2500C-C100 CPU with 128K User Memory
  • CTI 2500C-8-AO 8 Analog Outputs
  • CTI 2500C-8-AI 8 Analog Inputs
  • CTI 2559-FCAL Precision Calibration Connector
  • CTI 2559-FPC 40-Position Screw-Terminal Connector
  • CTI 2500-RFC PLC to RF Modem Cable
  • CTI 2500-40F 40-Position Standard Screw-Terminal Connector
  • CTI 2505 Vibration Sensor Interface Module
  • CTI 2554-A 4-Channel Isolated High Speed Counter Module
  • CTI 2553-A 2-Channel Mag Meter Input Module
  • CTI 2502 2-Channel High Speed Counter Input Module
  • CTI 2559-TC 8-Channel Thermocouple Input Module
  • CTI 2556-A 16-Channel Isolated Thermocouple Input Module
  • CTI 2556 16-Channel Isolated Thermocouple Input Module
  • CTI 2551-A 8-Channel Isolated Thermocouple Input Module
  • CTI 2559-RTD 8-Channel RTD Input Module
  • CTI 2557-A 16-Channel RTD Input Module
  • CTI 2557 16-Channel RTD Input Module
  • CTI 2552-A 8-Channel Isolated RTD Input Module
  • CTI 2534 8-Point Form-C Relay Output Module
  • CTI 2532 16-Point Form-A Relay Output Module
  • CTI  2531 32-Point Form-A Relay Output Module
  • CTI  2530 8-Point Form-C Relay Output Module
  • CTI  2562 8-Channel Analog Output Module
  • CTI  2560-A 8-Channel Isolated Analog Output Module
  • CTI  2501 8in/4out Analog Module
  • CTI  2558 8-Channel Analog Input Module
  • CTI  2555-A 16-Channel Analog Input Module
  • CTI  2550-A 8-Channel Isolated Analog Input Module
  • CTI  2599 8/16/32-Point AC Output Module
  • CTI  2598-8 8-Point AC Output Module
  • CTI   2598 8/16-Point AC Output Module
  • CTI   2597 8/16/32-Point DC Output Module
  • CTI 2596-8 8-Point DC Output Module
  • CTI 2596 8/16-Point DC Output Module
  • CTI 2595 16-Point TTL/Word Output Module
  • CTI 2591-EF 16-Point Isolated 11-146 VDC Output with Front Panel Accessible Fuses
  • CTI 2591-A 16-Point Isolated 11-146 VDC Output Module
  • CTI 2590-EF 16-Point Isolated 20-132 VAC Output with Front Panel Accessible Fuses
  • CTI 2590-A 16-Point Isolated Discrete 20-132 VAC Output Module
  • CTI 2589-B 8/16/32-Point Universal Discrete Input Module
  • CTI 2589-A 8/16/32-Point Universal Discrete Input Module
  • CTI 2588-8 8-Point Universal Discrete Input Module
  • CTI 2585 16-Point TTL/Word Input Module
  • CTI 2582 16-Point Isolated 125 VDC Input Module
  • CTI 2581 16-Point Isolated 12-56 VDC Input Module
  • CTI 2580 16-Point Isolated 95-132 VAC Input Module
  • CTI 2500-TAP RS485 Network Tap
  • CTI 2500-RIO-B RS485 Remote Base Controller
  • CTI 2500-RIO-A RS485 Remote Base Controller
  • CTI 2500-RBC Profibus Remote Base Controller
  • CTI 2515-A 100-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2515 100-Watt AC Power Supply (MATURE - replaced by 2515-A)
  • CTI 2513-A 75-Watt DC Power Supply with Redundancy Support
  • CTI 2513 75-Watt 24VDC Power Supply
  • CTI 2512-A 75-Watt AC/DC Power Supply with Redundancy Support
  • CTI 2512 75-Watt AC/DC Power Supply
  • CTI 2510 125 VDC Power Supply
  • CTI 2500-SSB Single Slot Blank Front Panel
  • CTI 2500-R11-A Eleven-Slot Redundant Base
  • CTI 2500P-R16 Sixteen-Slot Base with High-Speed Channel
  • CTI 2500P-R8 Eight-Slot Base with High-Speed Channel
  • CTI 2500P-R4 Four-Slot Base with High-Speed Channel
  • CTI 2541 Redundant Processor Manager Module
  • CTI 2577 Profibus DP Slave Adapter
  • CTI 2573-MOD Serial Interface Adapter with MODBUS
  • CTI 2572-AF Fast Ethernet TCP/IP Adapter with Optical Fiber Connection
  • CTI 2572-A Fast Ethernet TCP/IP Adapter
  • CTI 2572 Ethernet TCP/IP Adapter
  • CTI 2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2576 DeviceNet™ Scanner Module (MATURE)
  • CTI 2500P-ECC1 Ethernet Communications Coprocessor
  • CTI 2500P-JACP Janus Application Coprocessor
  • CTI 2500P-ACP1 Application Coprocessor (MATURE - replaced by 2500P-JACP)
  • CTI 2500P-J450 Janus PAC with 2MB Project Memory
  • CTI 2500-C400 CPU with 3072K User Memory
  • CTI 2500-C300 CPU with 512K User Memory
  • CTI 2500-C200 CPU with 256K User Memory
  • CTI 2500-C100 CPU with 128K User Memory
  • CTI 2500P-J750 Janus PAC with 3MB Project Memory
  • Shinkawa WHF3006M Displacement Converter
  • Shinkawa JBP-220 (P-24-94A / P-24-94B) Circuit Board Module
  • SHINKAWA   WKN-142K5  2-WIRE VIBRATION TRANSDUCER
  • Shinkawa FRP-321 (P-26-54A / P-26-54B) Circuit Board Module