B&R2CP100.60-1 CPU MODULE
Material number:
2DS100.60-1
Description:
2010 electronic drum sequencer Absolut encoder, SSI/parallel, 16 bit 3 diff. inputs, RS422 level, 100 kHz 3 diff.
outputs, RS422 level, 100 kHz 16 digital inputs 24 VDC, 5 µsec, sink Order terminal block 1 x TB140 separately!
The I/O bus operates e.g. digital and analog I/O modules, positioning modules, intelligent I/O
processors, etc.
If there is insufficient space available on the main rack for your application, further I/O modules
can be operated on up to four expansion racks. This procedure is called local expansion or I/O
bus expansion. Data transfer to these expansion racks is made simultaneously and with secure
protocol.
4.3 System Interface
The system interface is the sum of all I/O modules, i.e. the interface between PLC and the
machine/system being controlled. All B&R SYSTEMS 2005 I/O modules are electrically isolated
from external disturbances using suitable EMC measures (standard EN61131-2). I/O modules
are enclosed (plastic housing), so that the technician cannot come into contact with the
electronics at installation.
The length and structure of the I/O bus can be adjusted to the requirements of the
machine/system. That means the connection points for I/O signals do not have to be in the same
location as the PLCs CPU. Using a combination of local and remote I/O bus segments (remote
I/O) allows the optimal structure to be created for the respective application. I/O modules are
installed on the machine/system where they are needed. Cabling to the PLC kernel is reduced
to a two conductor or fiber optic cable.
4.4 Industrial PC
The combined I/O bus and system bus is multiprocessor-capable and therefore can hold further
computer units capable of dealing with additional tasks.
4.5 Network Capability
Network capability and the possibility to communicate with systems from other manufacturers
have become a must for all industrial controllers. The B&R 2000 PLC family meets many of these
requirements using system-wide and multi-system communication possibilities
4.6 Software Concept
Special attention was given to simple operation and programming. Standard PLC programs run
cyclically, i.e. the program is repeated in a loop. To increase efficiency, the B&R SYSTEM 2000
also offers the possibility to use various tasks with different cycle times. In this way, time critical
program sections (e.g. reaction to trigger signals) can be processed faster than the evaluation
of slower events (e.g. polling keys).
4.7 Programming
Programming is carried out using B&R Automation Studio™. Several programming languages
are available:
• Automation Basic (previously PL2000)
• ANSI C
• IEC 1131 Ladder Diagram (LAD)
• IEC 1131 Sequential Function Chart (SFC)
• IEC 1131 Structured Text (ST)
• IEC 1131 Instruction List (IL)
Differences in data type names between B&R Automation Studio™ and PG2000
The B&R 2005 is made up of individual modules that are housed in plastic. The modules (with
the exception of the power supply and the CPU) can be inserted in any order on a backplane.
The power supply must always be located on both far left slots of the backplanes. The CPU must
be operated directly next to the power supply.
Both the bus system and the supply lines are on the backplane. Backplanes are available in
different lengths (6. 9. 12 and 15 slots).
5.1.1 Mounting the Backplane
The backplane is installed on a mounting rail (DIN EN 50022 - 35 x 7.5 mm). This mounting rail
is attached conductively to the back wall of the switching cabinet.
In addition to mounting rail installation, the backplane can also be screwed directly onto the back
wall of the switching cabinet
| 3ASC25H208 DATX100 Pulse transformer board |
| 3ASC25H209 DATX110 high-performance I/O module |
| D202593 high-performance industrial automation controller module |
| HP5519A helium-neon (HeNe) laser system primarily |
| UAB016BE HIEE200114R1 Ground fault monitoring |
| FC-SDO-0824 8-channel fail-safe digital output module |
| 1786-RPFRL Fiber Ring Repeater Module |
| D26MRD704A1 multi-pole DC relay |
| IC670ALG310-JA Rx7i PACsystem IC670ALG310 module |
| MS-NAE5510-3E network automation engine (NAE) |
| F8621A 984862160 communication module for Safety Instrumentation systems |
| SR469-P5-HI-A20-E SR 469 Motor Management Relay line |
| DS200TCRAG2A RELAY OUTPUT BOARD |
| UG-25 8528-105 UG-25+ governor |
| 9907-167 505E Digital Governor for Extraction Steam Turbines |
| PR6423/003-131 8mm Eddy Current Sensor |
| 151X1235BC01SA01 Ethernet Switch 10-slot |
| SST-PFB3-VME-1 interface cards |
| VE4006P2 M-series Serial Interface Series 2 |
| UNITROL1000 Z.V3 3BHE014557R0003 Automatic voltage regulators (AVR) |
| Shinkawa VM-5K VM-5 Series monitor |
| IS200AEADH4A ALTERNATIVE ENERGY APPLICATION D |
| IS200WETBH1B Top Box B Board Assembly |
| IS220PDIAH1A Discrete Input Pack |
| TIS600-128-RED switching power |
| IS220PDIOH1A DISCRETE CONTACT INPUT/OUTPUT TERMINAL BOARD |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|