Programmable– The discrete output has been assigned a default function
using the LogicsManager.– The following text describes how these functions are
assigned using the LogicsManager.– It is possible to change the function of the discrete output if
required.– The following description of the outputs, labeled with "pro
grammable", refers to the preconfiguration.
n Fixed– The discrete output has a specific function that cannot be
changed depending upon the configured application mode.– The discrete output cannot be viewed or changed in the
LogicsManager.– However, the discrete output may be programmable in
some application modes
utput Type/Preset Description
Relay output [R 01] Programmable
Fixed to "Ready for operation"
CAUTION! Only relay [R 01] has an
inverse logic. The relay opens (all other
relays close), if the logical output of the
LogicsManager becomes TRUE.
This discrete output is used to ensure that the internal functions
of the controller are operating properly.
It is possible to configure additional events, which cause the con
tacts of this discrete output to open, using the LogicsManager.
Relay output [R 02] Programmable
Preconfigured to "Centralized alarm (horn)"
When a centralized alarm is issued, this discrete output is ena
bled.
A horn or a buzzer maybe activated via this discrete output.
Pressing the button with the "3" symbol will acknowledge the
centralized alarm and disable this discrete output.
The discrete output will re-enable if a new fault condition resulting
in a centralized alarm occurs. The centralized alarm is initiated by
class B alarms or higher.
Relay output [R 03] Programmable
Preconfigured to "Starter"
The generator starting circuit is engaged when this discrete
output is enabled.
This discrete output will enable depending on the start sequence
(refer to the start sequence description in Ä Chapter 4.4.1.1
“Configure Engine (general)” on page 156) to energize the starter
for the configured starter time (parameter 3306 Ä p. 167).
Relay output [R 04] Programmable
Preconfigured to "Start/Gas"
Fuel solenoid
The fuel solenoid for the diesel engine is energized when this dis
crete output is enabled. If the engine is given a stop command or
engine speed drops below the configured firing speed, this dis
crete output is disabled immediately.
Gas valve
The gas valve for the engine is energized when this discrete
output is enabled. If the engine is given a stop command or
engine speed drops below the configured firing speed, this dis
crete output is disabled immediately
Output Type/Preset Description
Relay output [R 05] Programmable
Preconfigured to "Preglow"
Preglow
When this discrete output is enabled, the diesel engine's glow
plugs are energized. This function only occurs if the control has
been configured for diesel engine start/stop logic.
Ignition
When this discrete output is enabled, the gas engine's ignition is
enabled. This function only occurs if the control has been config
ured for gas engine start/stop logic.
Notes
Refer to Ä Chapter 4.4.1.1 “Configure Engine (general)”
on page 156
Relay output [R 06] Fixed to "Command: close GCB" Only applicable for application modes and .
The "Command: close GCB" output issues the signal for the GCB
to close. This relay may be configured as an impulse or steady
output signal depending on parameter 3414 Ä p. 219.
Impulse
If the output is configured as "Impulse", the discrete output will
enable for the time configured in parameter 3416 Ä p. 219). An
external holding coil and sealing contacts must be installed into
the GCB closing circuit if this discrete output is configured for an
impulse output signal.
Steady
If the relay is configured as "Steady", the relay will energize and
remain enabled as long as the discrete input "Reply GCB"
remains de-energized and the generator and busbar voltages are
identical. If a class C or higher alarm occurs, this discrete will dis
able and the GCB will open immediately.
Relay output [R 07] Fixed to "Command: open GCB" Not applicable for application mode
The parameter 3403 Ä p. 219 defines how this relay functions.
If this output is configured as "N.O.", the relay contacts close
resulting in the GCB opening circuit energizing.
If this output is configured as "N.C.", the relay contacts open
resulting in the GCB opening circuit de-energizing.
If this output is configured as "Not used", this relay is freely con
figurable.
Application mode
The open GCB command remains enabled until the GCB is man
ually closed and the discrete input "Reply GCB" is energized. The
open GCB command will be issued when a fault condition or an
engine shut down occurs.
Application mode or
The controller enables the open GCB command when the GCB is
to be opened for switching operations. If the discrete input "Reply
GCB" is energized, the open GCB command will be disabled.
Relay output [R 08] Fixed to "Command: close MCB" Only applicable for application mode .
The discrete output "Command: close MCB" is an impulse output
signal.
This discrete output is enabled for the time configured in param
eter 3417 Ä p. 225.
An external holding coil and sealing contacts must be utilized with
the MCB closing circuit.
Relay output [R 09] Fixed to "Command: open MCB" Only applicable for application mode .
The controller enables this discrete output when the MCB is to be
opened for switching operations.
If the discrete input "Reply MCB" is energized, the discrete output
"Command: open MCB" is disabled.
| GE | IS220PAOCH1A |
| GE | IS200SDIIH1ADB MRP683026 |
| GE | IS220PDIIH1B 336A5026ADP1 |
| GE | IS230SNIDH1A MRP689579 |
| GE | IS200TREGH1BEC |
| GE | DS3800DFXA1B1C |
| GE | HE693ADC409A-22 |
| GE | IC660ELB921M |
| GE | CP238TA |
| GE | CP238/TA1 |
| GE | SR745-W2-P5-G5-HI |
| GE | IS220PSVOH1B |
| GE | RV33-1 |
| GE | VMICPCI-7806-211000 350-657806-211000L |
| GE | SR745-W3-P5-G5-HI |
| GE | IS200EGDMH1AFF |
| GE | IS200SPIDG1ABA |
| GE | IS200EGDMH1ADF |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|