DCS Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
HIRSCHMANN BRS20-1200ZZZZ-STCY99HHSES
❤ Add to collection

HIRSCHMANN BRS20-1200ZZZZ-STCY99HHSES

HIRSCHMANN BRS20-1200ZZZZ-STCY99HHSES

7150.00
¥6580.00
¥6580.00
¥6580.00
Weight:2.000KG
Description

HIRSCHMANN BRS20-1200ZZZZ-STCY99HHSES


HIRSCHMANN BRS20-1200ZZZZ-STCY99HHSES 

Product: BRS20-1200ZZZZ-ETCZ99HHSESXX.X.XX

Configurator: BOBCAT configurator

Configurator Description

The Hirschmann BOBCAT Switch is the first of its kind to enable real-time communication using TSN. To effectively support the increasing real-time

communication requirements in industrial settings, a strong Ethernet network backbone is essential. This compact managed switches allow for expanded

bandwidth capabilities by adjusting your SFPs from 1 to 2.5 Gigabit – requiring no change to the appliance.

Product description

Description Managed Industrial Switch for DIN Rail, fanless design Fast Ethernet Type

Configurator Part

Number 942170999

Port Type and Quantity 12 Ports in total: 8x 10/100BASE TX / RJ45; 4x 100Mbit/s fiber ; 1. Uplink: 2 x SFP Slot (100 Mbit/s) ; 2. Uplink: 2 x SFP Slot (100 Mbit/s)

More Interfaces

Power supply/signaling

contact 1 x plug-in terminal block, 6-pin

Digital Input 1 x plug-in terminal block, 2-pin 1 x plug-in terminal block, 2-pin

Local Management and

Device Replacement USB-C

Network size - length of cable

Twisted pair (TP) 0 - 100 m

Single mode fiber (SM)

9/125 µm see SFP fiber modules see SFP fiber modules

Single mode fiber (LH)

9/125 µm (long haul

transceiver)

see SFP fiber modules see SFP fiber modules

Multimode fiber (MM)

50/125 µm see SFP fiber modules see SFP fiber modules

Multimode fiber (MM)

62.5/125 µm see SFP fiber modules see SFP fiber modules

Network size - cascadibility

Line - / star topology any

Power requirements

Operating Voltage 2 x 12 VDC ... 24 VDC

Power Consumption 9 W

Power output in BTU

(IT)/h 31

Software

Switching

CoS Queue Management, Egress Interface Shaping, Fast Aging, Flow Control (802.3X), Forward unknown multicast to query ports per vlan, GARP Multicast Registration Protocol

(GMRP), GARP VLAN Registration Protocol (GVRP), IGMP Snooping/Querier per VLAN (v1/v2/v3), Independent VLAN Learning, Ingress Storm Protection, Interface Trust Mode,

Jumbo Frames, Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP), Multiple VLAN Registration Protocol (MVRP), QoS / Port Prioritization (802.1D/p),

Queue-Shaping / Max. Queue Bandwidth, Static Unicast/Multicast Address Entries, TOS/DSCP Prioritization, TSN 802.1Qbv Support on interfaces 1/1 - 1/3., Unknown Multicast

Filtering, VLAN (802.1Q), Voice VLAN

Redundancy HIPER-Ring (Ring Switch), Link Aggregation with LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2) - Redundancy Client, Media Redundancy Protocol (MRP)

(IEC62439-2) - Redundancy Manager, Redundant Network Coupling, RSTP 802.1D-2004 (IEC62439-1), RSTP Guards

Management Dual Software Image Support, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2. HTTP, HTTPS, IPv6 Management, Traps, SNMP v1/v2/v3. SNMPv3 Traps, Telnet


  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units