OMRON CJ1W-MD261 Digital I/O
CJ1W-MD261
CJ I/O, 32 in, NPN/PNP 24 VDC schakelvertraging instelbaar, 32 uit, transistor NPN
, 24 VDC / 0.3 A, met 2 x 40 punts Fujitsu aansluiting
Specificaties
I/O system CJ I/O Bus
Expansion unit type Basic I/O Unit
Type of module Digital I/O
Number of digital inputs 32
Digital input type PNP/NPN
Permitted voltage at input 20.4-26.4 V
OFF/ON delay 0-32 ms
Number of digital outputs 32
Digital output type NPN
Permitted voltage at output 10.2-26.4 V
Output current 0.3 A
Short-circuit protected outputs
I/O connection type FCN (plug not included)
Number of I/O connectors 2
Detachable I/O terminal block
Suitable for safety functions
Number of IOV (V+) terminals 4
Number of IOG (V-) terminals 4
Number of COM terminals 4
Product Height (unpacked) 90 mm
Product Width (unpacked) 31 mm
Product Depth (unpacked) 66.5 mm
Product Weight (unpacked) 110 g

Forced Status Hold Bit at
Startup
Power
ON
Non-retained parts
of I/O memory:
Retained
Power on Retained
IOM Hold Bit: 1
(ON)
Not retained when
power is turned ON.
Retained when
power is turned ON.
The Forced Status Hold Bit (A50013) can be turned ON to retain the forced
status of all bits that have been force-set or force-reset when the CPU Unit’s
operating mode is switched between PROGRAM mode and RUN/MONITOR
mode. When the PLC is turned on, the Forced Status Hold Bit itself will be
cleared (OFF) unless it is protected with this PLC Setup setting.
If the Forced Status Hold Bit at Startup setting is ON, the status of the Forced
Status Hold Bit will be protected when the PLC is turned on. If this setting is
ON and the Forced Status Hold BIt itself is ON, all force-set and force-reset
bits will retain their forced status when the PLC is turned on.
Note If the backup battery fails or is disconnected, the Forced Status Hold Bit will
be cleared whether this setting is ON or OFF.
OFF (0): Forced Status Hold Bit cleared at start-up
Forced bit status
Mode switch Retained
Forced Status
Hold Bit: 1 (ON)
Forced bit status
Mode switch Retained
Power
OFF
Power
ON
Forced bit status
Power ON Not retained
Forced Status
Hold Bit: 0 (OFF)
ON (1): Forced Status Hold Bit protected at start-up
Power
OFF
Forced Status
Hold Bit: 1 (ON)
Startup Mode Setting
Power
ON
Forced bit status
Power ON Retained
Forced Status
Hold Bit: 1 (ON)
Not retained
when power is
turned ON.
Retained when
power is turned
ON.
This setting determines whether the startup mode will be the mode set on the
Programming Console’s mode switch or the mode set here in the PLC Setup.
Note If this setting specifies the mode set on the Programming Console’s mode
switch (0) but a Programming Console isn’t connected, the CPU Unit will auto
matically enter RUN mode at startup. (This differs from the default operation
for CS-series CPU Units.)
PRCN: Programming Console's mode switch
Mode switch
setting
Power ON
Other: PC Setup's Startup Mode setting
PRG: PROGRAM mode
MON: MONITOR mode
RUN: RUN mode
Power ON
RUN mode when
disconnected.
Power ON
Note If a Programming Console is not connected when the PLC Setup is set to use
the mode set on the Programming Console’s mode switch, the CPU Unit will
start in RUN mode.