Omron Safety Input Unit NX-SIH400
Omron Safety Input Unit NX-SIH400
Alarm Types
Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit. (see note.)
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note:In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed.
To use alarm 1. set the output assignment to alarm 1.
Set
value Alarm type
Alarm output operation
Description of function When alarm value X
is positive
When alarm value X
is negative
0 Alarm function OFF Output OFF No alarm
1 Upper- and lower-limit *1 *2
Set the upward deviation in the set point for the alarm upper
limit (H) and the lower deviation in the set point for the alarm
lower limit (L). The alarm is ON when the PV is outside this
deviation range.
2
(default) Upper-limit
Set the upward deviation in the set point by setting the alarm
value (X). The alarm is ON when the PV is higher than the
SP by the deviation or more.
3 Lower-limit
Set the downward deviation in the set point by setting the
alarm value (X). The alarm is ON when the PV is lower than
the SP by the deviation or more.
4 Upper- and lower-limit
range *1 *3
Set the upward deviation in the set point for the alarm upper
limit (H) and the lower deviation in the set point for the alarm
lower limit (L). The alarm is ON when the PV is inside this
deviation range.
5 Upper- and lower-limit with
standby sequence *1 *4 A standby sequence is added to the upper- and lower-limit
alarm (1). *6
6 Upper-limit with standby
sequence A standby sequence is added to the upper-limit alarm (2). *6
7 Lower-limit with standby
sequence A standby sequence is added to the lower-limit alarm (3). *6
8 Absolute-value upper
limit
The alarm will turn ON if the process value is larger than the
alarm value (X) regardless of the set point.
9 Absolute-value lower-limit The alarm will turn ON if the process value is smaller than the
alarm value (X) regardless of the set point.
10
Absolute-value upper
limit with standby
sequence
A standby sequence is added to the absolute-value upper
limit alarm (8). *6
11 Absolute-value lower-limit
with standby sequence
A standby sequence is added to the absolute-value lower
limit alarm (9). *6
12 LBA (alarm 1 type only)-*7
13 PV change rate alarm-*8
14 SP absolute-value
upper-limit alarm
This alarm type turns ON the alarm when the set point (SP)
is higher than the alarm value (X).
15 SP absolute-value
lower-limit alarm
This alarm type turns ON the alarm when the set point (SP)
is lower than the alarm value (X).
16 MV absolute-value
upper-limit alarm *9
Standard Control Standard Control
This alarm type turns ON the alarm when the manipulated
variable (MV) is higher than the alarm value (X). Heating/Cooling
Control (Heating MV)
Heating/Cooling
Control (Heating MV)
Always ON
| BMXDDI3202K Schneider remote IO drop E/IP Modicon X80 |
| BMXCRA31210 Schneider remote IO drop E/IP Modicon X80 |
| BMXAMI0800 Schneider analog output module |
| IS220PHRAH1BD JG3A0S1 I/O pack module GE |
| IS220PDIIH1BD JG3C0WZ I/O pack module GE |
| IS220YDOAS1AJ Speedtronic Turbine Control PCB board GE |
| IRDH275-435 BENDER Digital Ground Fault Monitor / Ground Detector |
| 1783-HMS8T4CGN Allen Bradley Stratix 5400 Industrial Managed Switch |
| AINT-02C ABB Spare PCB Main Interface Kit |
| D201832 Metso RT node PC AP31 D200137 personality module |
| D201138 Metso RT node PC AP31 D200137 personality module |
| D201473 Metso RT node PC AP31 D200137 personality module |
| D201479 Metso RT node PC AP31 D200137 personality module |
| 5X00270G01 ANALOG INPUT MODULE EMERSON |
| 9907-173 Woodward Inc Load Sharing units |
| PP885R 3BSE069296R1 Touch Panel 15,4ABB |
| DSQC1003 3HAC046408-001 ABB Robot communication board |
17 MV absolute-value
lower-limit alarm *9
Standard Control Standard Control
This alarm type turns ON the alarm when the manipulated
variable (MV) is lower than the alarm value (X). Heating/Cooling
Control (Cooling MV) Heating/Cooling
Control (Cooling MV)
Always ON
18 RSP absolute-value
upper-limit alarm *10
This alarm type turns ON the alarm when the remote SP
(RSP) is higher than the alarm value (X).
19 RSP absolute-value
lower-limit alarm *10
This alarm type turns ON the alarm when the remote SP
(RSP) is lower than the alarm value (X)
1.With set values 1. 4 and 5. the upper and lower limit values can
be set independently for each alarm type, and are expressed as
“L” and “H.”
*2.Set value: 1. Upper- and lower-limit alarm
*3.Set value: 4. Upper- and lower-limit range
*4.Set value: 5. Upper- and lower-limit with standby sequence
For Upper- and Lower-Limit Alarm Described Above *2
• Case 1 and 2
Always OFF when the upper-limit and lower-limit hysteresis overlaps.
• Case 3: Always OFF
*5.Set value: 5. Upper- and lower-limit with standby sequence
Always OFF when the upper-limit and lower-limit hysteresis
overlaps.
*6.Refer to the E5@C Digital Temperature Controllers User's Manual
(Cat. No. H174) for information on the operation of the standby
sequence.
*7.Refer to the E5@C Digital Temperature Controllers User's Manual
(Cat. No.H174) for information on the loop burnout alarm (LBA).
*8.Refer to the E5@C Digital Temperature Controllers User's Manual
(Cat. No. H174) for information on the PV change rate alarm.
*9.When heating/cooling control is performed, the MV absolute
upper limit alarm functions only for the heating operation and the
MV absolute lower limit alarm functions only for the cooling
operation.
*10.This value is displayed only when a remote SP input is used. It
functions in both Local SP Mode and Remote SP Mode.
Remote SP input is supported only for the E5CC.

| User name | Member Level | Quantity | Specification | Purchase Date |
|---|