OMRON SYSMAC SCY-P1 Sequential Controller
OMRON SYSMAC SCY-P1 Sequential Controller
Specifications
Ratings
*1.There are no optional functions for the E5CC-U. Refer to Model Number Legend and List of Models on page21.
*2.This function is not supported by the E5CC-B. Refer to Model Number Legend on page20.
*3.With the E5CC-B, there can be up to four set points if event inputs are used to select them.
Power supply voltage A in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range 85% to 110% of rated supply voltage
Power consumption
Models with option selection of 000:5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at 24 VAC or
1.6 W max. at 24 VDC
All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC
Sensor input
Temperature input
Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
Analog input
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V,or 0 to 50 mV (The 0 to 50 mV range applies to the
E5CC-U only for those manufactured in May 2014 or later.)
Input impedance Current input: 150 Ω max., Voltage input: 1 MΩ min.
(Use a 1:1 connection when connecting the ES2-HB-N/THB-N.)
Control method ON/OFF control or 2-PID control (with auto-tuning)
Control
output
Relay output
E5CC/E5CC-B:SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100.000 operations,
minimum applicable load: 5 V, 10 mA (reference value)
E5CC-U: SPDT, 250 VAC, 3 A (resistive load), electrical life: 100.000 operations,
minimum applicable load: 5 V, 10 mA (reference value)
Voltage output
(for driving SSR) Output voltage: 12 VDC ±20% (PNP), max. load current: 21 mA, with short-circuit protection circuit
Linear current output 4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10.000
Auxiliary
output
Number of outputs
E5CC: 3
E5CC-B: 2
E5CC-U: 1 or 2 (depends on model)
Output specifications
SPST-NO relay outputs, 250 VAC, Models with 1 output: 3 A (resistive load), E5CC-U models with 2
outputs: 3 A (resistive load), E5CC-B models with 2 outputs: 2 A (resistive load), Models with 3
outputs: 2 A (resistive load), Electrical life: 100.000 operations, Minimum applicable load: 10 mA at
5V (reference value)
Event
| IS200AEPAH1AFD GE GER-4193A GE Power Systems Manual |
| IS200AEPAH1BKE GE printed circuit board |
| DS200ADCIH1A GE Genius Adapter Board |
| FC-IO-0001 Safety Manager System Module HONEYWELL |
| 330980-71-CN Bently Nevada NSv Proximitor Sensor |
| 330105-02-12-10-02-CN 3300 XL 11 mm Probe Bently Nevada |
| 330910-05-15-10-02-00 3300 XL 11 mm Probe Bently Nevada |
| PR6423/011-110+CON021 vibration pickup EPRO |
| 2711P-T10C4D2 Allen-Bradley PanelView Plus 1000 Operator Terminal |
| 2711P-RP2X Allen-Bradley DC-powered logic module |
| 2711P-T7C4D2 Allen Bradley PanelView Plus 700 Operator Terminal |
| SC2L-95UVS2-1CEX FIREYE flame scanners are micro-processor |
| 95UVS1E-1CEX FIREYE flame scanners are micro-processor |
| XV-230-57MPN-1-10 Touch panel EATON |
| XVS-440-10MPI-1-10 Touch panel EATON |
| XV-102-B2-35TQR-10 Touch panel EATON |
| 2198-H003-ERS Allen-Bradley Kinetix 5500 Servo Drive |
| VPL-B0753F-PJ14AA Allen-Bradley VPL Series Low Inertia servo motors |
| VPL-B1003T-PJ12AA Allen-Bradley Brushless AC asynchronous motor |
input *1
Number of inputs E5CC: 2 or 4 (depends on model)
E5CC-B: 2 (depends on model)
External contact input
specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Transfer
output *1
Number of outputs 1 (only on models with a transfer output)
Output specifications Current output: 4 to 20 mA DC, load: 500 Ω max., resolution: approx. 10.000
Linear voltage output: 1 to 5 VDC, load: 1 kΩ min., resolution: Approx. 10.000
Setting method Digital setting using front panel keys
Remote SP input *1 *2 Current input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150 Ω max.)
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V (input impedance: 1 MΩ min.)
Indication method 11-segment digital display and individual indicators
Character height: PV: 15.2 mm, SV: 7.1 mm
Multi SP *3 Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations,
or serial communications.
Bank switching None
Other functions
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater
burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital
filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root,
MV change rate limit, logic operations, temperature status display, simple programming, moving
average of input value, and display brightness setting
Ambient operating temperature −10 to 55°C (with no condensation or icing), For 3-year warranty: −10 to 50°C with standard mounting
(with no condensation or icing)
Ambient operating humidity 25% to 85%
Storage temperature-25 to 65°C (with no condensation or icing)
Altitude 2.000 m max.
Recommended fuse T2A, 250 VAC, time-lag, low-breaking capacity
Installation environment Overvoltage category II, Pollution Degree 2 (EN/IEC/UL 61010-1