IBA ibaPADU-8AI-I Compact Measurement Modules
IBA ibaPADU-8AI-I Compact Measurement Modules
Modules in the I/O Manager
If you want to use ibaBM-ENetIP with ibaPDA, you have to configure the device in the
ibaPDA I/O Manager. Use the step-by-step procedure described in chapter 9.1.
In the following paragraphs, we describe the available modules.
"ibaBM-ENetIP“ device module
The module "ibaBM-ENetIP" contains of 4 different tabs. The "General" and "Diagnos
tics" tabs are always visible. The "Analog" and the "Digital" tab contain dynamic online
views of the analog and digital signals acquired by the device. This is why these two tabs
are only visible after modules of „EtherNet/IP sniffer“ type have been added and the
configuration has been transferred to the device.
Locked
A module can be locked in order to prevent accidental or unauthorized changes in the
module settings.
❑ Enabled
Disabled modules are excluded from signal acquisition.
❑ Name
Enter here the name for the module as clear text.
❑ Timebase
Timebase for the data acquisition which is used for this device in ms. Cycles of down to
1 ms are possible (depending on the number of the signals).
❑ Use name as prefix
The module name is placed in front of the signal name as prefix.
Connection
❑ IP address
IP address of the device (via FO); cannot be changed.
❑ Auto enable/disable
If the value is TRUE, the data acquisition is started even though the device is miss-ing.
The missing device is temporarily disabled in the configuration. During the measurement
process, ibaPDA tries to re-establish the connection to the missing device. If this is suc
cessful, the measurement is restarted automatically including the device that has been
missing. If the value is FALSE, the measurement will not be started, in case ibaPDA
cannot establish a connection to the device.
9.2.1.2 “Analog“ tab
If analog signals have been configured in the modules „EtherNet/IP sniffer“ and the con
figuration has been transferred to ibaBM-ENetIP, you will see here an overview of all
acquired analog signals with an online overview of the currently acquired values.
“Digital“ tab
If digital signals have been configured in the modules „Device slot“ and the configuration
has been transferred to ibaBM-ENetIP, you will see here an overview of all acquired
digital signals with an online overview of the currently acquired values.
| IPFAN12 Fan Unit 230 Vac |
| 2RCA025059A0901 Control of AC and DC power circuits |
| 2711-K6C16 PanelView Standard Operator Terminals |
| 51304754-176 MC-PAIH03 High Level Analog Input Processor-16 Inputs |
| 02000-A-1645 Series 2000 Calibration Flow Housing Assembly |
| FC-SSWM01 SC SWITCH MODULE PROGRAM/FORCE/RESET |
| FC-TSPKUNI-1624 Safe Functional Test Adapter (FTA) |
| FC-GMLA16 16-Channel Digital Input FTA Dual Channel CC |
| FC-TPSU-2430 Safety Manager System Module |
| FC-SAO-0220M HONEYWELL Safe Digital Output FTA |
| FC-TSDO-0824C HONEYWELL Safe Digital Output FTA |
| 560PSU02 R0001 1KGT011900R0001 Communication unit ABB |
| SPCJ4D34-DASPAJ 140 C Overcurrent and earth-fault relay |
| REF615 HCFKAEADABC2BAA11E聽 Feeder Protection and Control |
| 8220-DI-IS8-channel Intrinsically Safe RTD input |
| REM615C_E Motor Protection and Control |
| 8215-DO-IS 8-channel Intrinsically Safe RTD input |
| 8205-TI-IS 8-channel Intrinsically Safe RTD input |
| S71202-NANANA servo driver KOLLMORGEN |
| FX-USI-0002 Safety Manager System Module |
| 833-004563-007 Radio-frequency matcher Suitable |
| 853-028873-510 Radio-frequency matcher Suitable |
| 810-028296-173 Radio-frequency matcher Suitable |
| 810-800256-207 Radio-frequency matcher Suitable |
| 839-195167-001 Radio-frequency matcher Suitable |
| 772-032738-005 SMC regulator |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|