DCS; Industrial control system
NameDescriptionContent
Argument
Current Location:
PRODUCT SHOW
IBA  ibaPADU-D-8AI-U  Compact Measurement Modules
❤ Add to collection

IBA ibaPADU-D-8AI-U Compact Measurement Modules

IBA  ibaPADU-D-8AI-U  Compact Measurement Modules

9680.00
¥8566.00
¥8566.00
¥8566.00
Weight:2.000KG
Description

IBA  ibaPADU-D-8AI-U  Compact Measurement Modules


IBA  ibaPADU-D-8AI-U  Compact Measurement Modules

Fiber optic connections X10 and X11

❑ X11 (RX): FO receiving interface

❑ X10 (TX): FO sending interface

On the ibaPDA system, a FO input/output card of the ibaFOB-D or ibaFOB-Dexp type or

an ibaFOB-ioUSB adapter has to be installed for receiving and sending the data.

Maximum distance of fiber optic connections

The maximum distance of fiber optic connections between 2 devices depends on various

influencing factors. This includes, for example, the specification of the fiber (e.g.

50/125 μm, 62.5/125 μm, etc.), or the attenuation of other components in the fiber optic

cable plant such as couplers or patch panels.

However, the maximum distance can be estimated on the basis of the output power of

the transmitting interface (TX) or the sensitivity of the receiving interface (RX). A model

calculation can be found in chapter 11.3.

The specification of the transmitter's output power and the receiver's sensitivity of the

fiber optic components installed in the device can be found in chapter 11.1 "Technical

data" under "ibaNet interface".

Voltage supply X14

The ibaBM-ENetIP device has to be operated with an external DC voltage 24 V (unreg

ulated) with a maximum current consumption of 400 mA. The operating voltage should

be supplied using the 2-pin Phoenix screw connector included in delivery.

Pushbutton S10

With the S10 pushbutton, all settings can be reset to the factory settings:

1. Switch off the device.

2. Switch on the device with the pushbutton S10 keeping pushed.

3. Keep the pushbutton S10 pushed until the green LED "Run" of the operating status

display starts blinking rapidly. Now, release the pushbutton.

4. When the green LED "Run" stops blinking rapidly, the factory settings have been

applied. The device is immediately ready for operation and does not need to be

switched off and on again.

Rotary switch S2

With the 32Mbit Flex protocol, up to 15 devices can be connected in a ring topology. The

devices are addressed using the rotary switch S2.

TAP interface X42

With the TAP interface, the device can be operated in an Ethernet network without any

interferences. The whole data exchange can be recorded.

Communication via the TAP interface is maintained even if the power supply is inter

rupted.

Service interface X12

The Ethernet interface „X12 Service“ (RJ45) at the bottom of the device is designated

for service purposes.

The Ethernet interface is set to a static IP address 192.168.1.1 which cannot be changed.

The service interface is not used at the moment.

Monitor interface X13

The Ethernet interface „X13 Monitor“ (RJ45. 1Gbit/s, no autonegotiation) at the bottom

of the device is designated for connecting a network analysis tool like e.g. Wireshark1.

The communication via the TAP interface is mirrored and output on the X13 Monitor in

terface.

Shield connector X29

Connector (screw) for connecting the protective ground. Depending on the configuration

of the control cabinet, it might be necessary to connect the shields of the network cable

to the shield connector X29. Use a M6 terminal for connecting purposes.

If the shields of the network cables have been connected yet to the protective ground of

the control cabinet, also connect the shield connector X29 to the protective ground of the

control cabinet.

IS215WEMAH1A WIND   AND SOLAR ENERGY MAIN I/O CONTROL BOARD
PXIE-4302 PXI Analog Input Module
5X00785G05 Power Distribution Module
LMC101CAA10000 motion controller   transistor sercos compact Ethernet
3500/53M 288062-01 3500/53 Electronic   Overspeed Detection System
3500/15-05-05-R0 Power Supply
IS200VRTDH1DAC VMR GENERAL ELECTRIC RTD   BOARD
REM620 NBMNACAAABC1BNN11G Motor   protection and control
IS200TVBAH1AAA VIBRATION TERMINAL BOARD
1900/65A-00-00-01-00-00 General Purpose   Equipment Monitor
PR6425/010-130+CONO21/915-040 Eddy   Current Signal Converter
490NRP25400 Enhancing Connectivity with   Fiber Optic Repeater
2094-BC07-MO5-S Kinetix 6000 Drive   component
IS200TRPGH1BDE PRIMARY TRIP TERMINAL   BOARD
DS2020FECNRX020A FIELD EXCITER BOARD
900C75S-0360-00 ControlEdge HC900 IO   Modules
IS2020RKPSG3A Mark VI VME Rack Power   Supply
XV-102-B6-35TQR-10-PLC Touch panel
LXM62DC13C21000 motion servo drive
AFV30D-A41252 Duplex field control unit
MDX60A0370-503-4-00 Servo driver
F650-B-F-G-F-1-G-1-HI-E GE Multilin F650
DS200PCCAG2ACB Power Connect Card
PXIE-4305 783868-01 32-ChannelAnalog   Input Module
PXIE-6614 782353-01 PXI Counter/Timer   Module
PXIE-8842 787882-01 Embedded-Controller   PXI-Systeme


  • IBA ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • Motorola MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP)DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06C HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ETT-VGA Human-machine interface touch unit
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP CP02R-04 Human-machine interface
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930-presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • FOXBORO Fieldbus Communications Module, FCM10Ef
  • FOXBORO Fieldbus Communications Module, FCM10E
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • MVME6100 Series VMEbus Single-Board Computer
  • Configuration for AMS 6500 Protection Monitors
  • Ovation™ Controller Model OCR1100 (5X00481G04/5X00226G04)
  • ABB UCU-22, UCU-23 andUCU-24control units
  • ABB force measurement
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management Simplifying Optical Networks
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect