Introduction 

Mark* VIe is a flexible control system for multiple applications. It features highspeed, networked I/O for simplex, dual, and triple redundant systems. Industrystandard Ethernet communications are used for I/O, controllers, and supervisory 

interface to operator and maintenance stations, and third-party systems. 

ToolboxST* is used for Mark VIe and related controls as a common software 

platform for programming, configuring I/O, trending, and analyzing diagnostics. It 

provides a single source of quality, time-coherent data at the controller and plant 

level for effectively managing equipment assets.

Architecture 

A single-board controller is the heart of the system. It includes the main processor 

and redundant Ethernet drivers for communicating with networked I/O and 

additional Ethernet drivers for the control network. A QNX® real-time, multitasking 

operating system is used for the main processor and I/O. Application software is 

provided in a configurable control block language, and is stored in non-volatile 

memory. It conforms to IEEE-854 32-bit floating-point format. 

IONet is a dedicated, full-duplex, point-to-point protocol that provides a 

deterministic, high-speed 100 MB communications network suitable for local or 

remote I/O with a fiber interface. It provides communication between the main 

processor(s) and networked I/O blocks, called I/O packs. 

100 MB Ethernet is used for 

communication to local and 

remote I/O packs. The IONet 

is available in single, dual, 

and triple configurations. 

Each I/O pack is mounted on a board with barrier or box-type terminal blocks. The 

I/O pack contains two Ethernet ports, a power supply, a local processor, and a data 

acquisition board. Computation power grows as I/O packs are added to the control 

system, enabling an overall control system frame rate of 10 ms in simplex, dual, or 

triple redundant configuration. Some process sub-systems require even more 

performance; therefore, the local processors in each I/O pack run algorithms at 

higher rates as required for the application. 

Redundancy 

Every application has different requirements for redundancy depending on the 

importance of the process. Mark VIe provides a wide range of redundancy options 

that can be supplied in virtually any combination and mounted local or remote. Some 

of these redundancy options include: 

• Power sources and supplies single, dual, and triple 

• Controllers (main processor) single, dual, and triple 

• I/O network redundancy single, dual, and triple 

• I/O packs per terminal board single, dual, and triple 

• Ethernet Ports / I/O pack single or dual 

System Architecture 

Controllers are continuously online and read input data directly from IONet. Dual 

redundant systems transmit inputs from one or redundant I/O packs on dual IONets 

to dual controllers. Outputs are transmitted to an output I/O pack that selects either 

the first healthy signal or the signal of choice. Three output packs can be provided to 

vote output signals for mission-critical field devices. 

Dual redundant systems can be configured for single, dual, and triple sensors. Their 

dual internal networks and controllers keep the process online if a controller or 

power supply fails. Triple redundant systems are available to protect against soft or 

partial failures of devices that continue to run but with incorrect signals/data. 

These systems out vote a failed component with a 2-out-of-3 selection of the signal. 

Application software in all three controllers runs on the voted value of the signal 

while diagnostics identify the failed device. These sophisticated diagnostics 

minimize the mean-time-to-repair (MTTR) while the on-line repair capability 

maximizes the mean-time-between-forced-outages (MTBFO). Field sensors for these 

systems can be single, dual, or triple. 

A second controller can be provided to separate the application software for different 

pieces of equipment. For example, a core engine control for an air-fuel governor can 

run in one controller while a second controller can be dedicated to auxiliary control. 

Note Every I/O pack communicates directly on IONet, which enables each I/O pack 

to be replaced individually without affecting any other I/O in the system. Also, the 

I/O pack can be replaced without disconnecting any field wiring. 

I/O Interface 

One or multiple I/O packs are mounted on each board to digitize the sensor signal, 

perform algorithms, and communicate with a separate controller that contains the 

main processor. I/O packs have a local processor board that runs a QNX operating 

system and a data acquisition board that is unique to the type of input device. Local 

processors run algorithms at faster speeds than the overall control system. 

An on-board temperature sensor 

provides continuous monitoring of 

the environment in remote 

  • NZMH2-A80-NA Eaton Series NZM complete molded case circuit breaker
  • Eaton Cutler-Hammer HFD3030 6639C86G87 3 Pole 30A 600V Circuit Breaker
  • Moeller XV-230-57CNN-1-13-1 HMI PLC Panel Touchscreen 5.7"
  • EATON CEAG CU CG-S , 40071360300 Control Unit
  • EATON SDN90186 MOTOR CONTROL CENTER
  • EATON HMCP150U4 CIRCUIT BREAKER
  • Eaton 7801C57 Digitrip Optimizer Hand Held Programmer
  • Eaton HMCP400R5 Circuit Breaker
  • EATON MP-3000 SAFETY RELAY 66D2032GX1 5A
  • EATON PGGLOBL1701DPRO 1785T Touch Panel
  • Eaton, Moeller, Easy MFD-CP8-NT
  • Eaton WL-35717F Vacuum Interrupter
  • EATON VICKERS EEA-PAM-535-A-32 AMPLIFIER CARD
  • EATON FP5000-00 / FP5200-00 66D2041G11 FEEDER PROTECTION RELAY
  • Eaton IQ-504 120VAC Modular Overload Relay
  • Beckhoff CX5620-0225    CPU module
  • Beckhoff CX5620-0220    CPU module
  • Beckhoff CX5620-0215    CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0210 CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0195    CPU module
  • Beckhoff CX5620-0190    CPU module
  • Beckhoff CX5620-0185    CPU module
  • Beckhoff CX5620-0175    CPU module
  • Beckhoff CX5620-0170    CPU module
  • Beckhoff CX5620-0163    CPU module
  • Beckhoff CX5620-0161 CPU module
  • Beckhoff CX5620-0160 CPU module
  • Beckhoff CX5620-0100 CPU module
  • Beckhoff CX5120-0195    CPU module
  • Beckhoff CX5120-0190 CPU module
  • Beckhoff CX5120-0185 CPU module
  • Beckhoff CX5120-0175 CPU module
  • Beckhoff CX5120-0170    CPU module
  • Beckhoff CX5120-0163    CPU module
  • Beckhoff CX5120-0162    CPU module,
  • Beckhoff CX5120-0161    CPU module
  • Beckhoff CX5120-0150 CPU module
  • Beckhoff CX5120-0143 CPU module
  • Beckhoff CX5120-0142 CPU module
  • Beckhoff CX5120-0141 CPU module
  • Beckhoff CX5120-0140 CPU module
  • Beckhoff CX5120-0130 CPU module
  • Beckhoff CX5120-0123 CPU module
  • Beckhoff CX5120-0122 CPU module
  • Beckhoff CX5120-0120 CPU module, Microsoft Windows Embedded Standard 7 P
  • Beckhoff CX5120-0113 CPU module
  • Beckhoff CX5120-0112 CPU module
  • Beckhoff CX5120-0111 CPU module
  • Beckhoff CX5120-0110 CPU module, Microsoft Windows Embedded Compact 7
  • Beckhoff CX5120-0100 CPU module, no operating system
  • Beckhoff C6017-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6017 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0030  | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff CX2500-M510 | Fieldbus master module
  • Beckhoff CX2500-M310 | Fieldbus master module
  • Beckhoff CX2500-B510 | Fieldbus slave module
  • Beckhoff CX2500-B310 | Fieldbus slave module PROFIBUS for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0070 | USB 3.0 module for CX20xx, CX52xx, CX53x0. CX56x0
  • Beckhoff CX2500-0062 | 2.5 Gbit Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1061 | Power over Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1060 | Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0031 | Serial Interface RS485/RS422 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0030 | Serial Interface RS232 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX5230-0195 CPU module
  • Beckhoff CX5230-0190  CPU module
  • Beckhoff CX5230-0175    CPU module,
  • Beckhoff CX5230-0170    CPU module
  • Beckhoff CX5230-0100   CPU module, no operating system, no TwinCAT
  • Beckhoff CU8130-0240 | UPS modul, battery-backed
  • Beckhoff CU8130-0120 | UPS module, battery-backed
  • Beckhoff CU8110-0120 | UPS module, capacitive
  • Beckhoff CU8110-0060 | UPS module, capacitive
  • Beckhoff CX5130-0195    CPU module
  • Beckhoff CX5130-0190    CPU module
  • Beckhoff CX5130-0185 CPU module
  • Beckhoff CX5130-0170    CPU module, Microsoft Windows 10 IoT Enterprise 2019 LTSC
  • Beckhoff  CX5130-0163 CPU module
  • Beckhoff  CX5130-0162    CPU module
  • Beckhoff CX5130-0161 CPU module
  • Beckhoff CX5130-0160    CPU module
  • Beckhoff CX5130-0155  CPU module
  • Beckhoff CX5130-0150    CPU module
  • Beckhoff CX5130-0143    CPU module
  • Beckhoff CX5130-0142 CPU module
  • Beckhoff CX5130-0140    CPU module
  • Beckhoff CX5130-0135 CPU module
  • Beckhoff CX5130-0130 CPU module
  • Beckhoff CX5130-0125  CPU module
  • Beckhoff CX5130-0123    CPU module
  • Beckhoff CX5130-0122    CPU module
  • Beckhoff CX5130-0121    CPU module
  • Beckhoff CX5130-0115    CPU module
  • Beckhoff CX5130-0113    CPU module
  • Beckhoff CX5130-0112 CPU module
  • Beckhoff CX5130-0111   CPU module
  • Beckhoff CX5130-0110 CPU module, Microsoft Windows Embedded Compact 7. no TwinCAT
  • Beckhoff CX5130-0100 CPU module, no operating system, no TwinCAT
  • DEIF FAS-113DG Synchronisation & circuit breaker closing
  • DEIF FAS-115DG Synchronisation & circuit breaker closing
  • DEIF HAS-111DG Synchronisation & circuit breaker closing
  • DEIF LSU-122DG Load sharing, paralleling & operation
  • DEIF LSU-114DG Load sharing, paralleling & operation
  • DEIF LSU-113DG Load sharing, paralleling & operation
  • DEIF LSU-112DG Load sharing, paralleling & operation
  • DEIF RMF-112D Frequency relay
  • DEIF RMC-142D Current relay
  • DEIF RMC-132D Current relay
  • DEIF RMC-131D Current relay
  • DEIF RMC-122D Current relay
  • DEIF RMC-121D Current relay
  • DEIF RMC-111D Current relay
  • DEIF MVR-V211 Busbar Protection
  • DEIF MVR-T257 Transformer Differential Protection
  • DEIF MVR-T256 Transformer Differential Protection
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Differential Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF MVR-G257 Generator Differential Protection
  • DEIF MVR-G215 Generator Protection
  • DEIF MVR-F255 Directional Feeder Protection
  • DEIF MVR-F215 Directional Feeder Protection
  • DEIF MVR-F210 Feeder Protection