To develop and maintain a competitive advantage, it’s time to take your plant digital, with the first fully digital automation system—the DeltaV™ system. With a suite of digital busses, precision advanced control, and easy enterprise integration and optimization, the DeltaV system helps you improve your operations—easy

The DeltaV Digital Automation System

igital plants made easy PlantWeb® is a digital plant architecture that delivers proven results, and the DeltaV system makes it easy. Designed with this digital architecture in mind, the DeltaV system fully integrates “smart plant” capabilities including HART®, FOUNDATION™ fieldbus, high-speed discrete busses, embedded advanced control, and advanced unit and batch management. This seamless, intelligent field integration provides the infrastructure for advanced applications such as AMS Suite: Intelligent Device Manager for quick, easy device re-ranging, configuration and diagnostics. The results are better process efficiency and reduced process variability. Any size you want The DeltaV system scales in both size and functionality. It’s the first fully digital system to offer you a single architecture with full functionality from a few to hundreds of thousands of I/O, so you can cost-effectively implement applications of any scope. You pick the functions that work best for your application across the entire system size. The DeltaV system integrates easily with your existing automation systems to provide you a path forward, allowing you to benefit from the latest costsaving technologies. Leading the way The DeltaV system has delivered a host of industry firsts—including simple plug-and-play OPC and XML integration, FOUNDATION fieldbus, batch control, and advanced control technologies. Being first with these technology innovations has made our users pacesetters in their industries. But more important, it’s delivered dramatic operational improvements: the kind of improvements you can start profiting from today. Results that deliver It’s no wonder that process automation professionals like you have voted the DeltaV system the leading process automation system for four consecutive years.† In the following pages, see why

A Better Approach to Digital

The DeltaV system, a key component of the PlantWeb architecture, is the world’s first digital automation system

Built with today’s technologies like PC workstations, Ethernet, digital busses, OPC and XML, the DeltaV system delivers more precise control, and predictive maintenance. And it delivers that information where and when it’s required. Unlike other systems, the technologies were built from the ground up into a digital automation architecture, not bolted on after the fact. That’s what makes the DeltaV system easy to learn, easy to use, easy to maintain, and easy to connect to your existing automation.

Availability While the DeltaV system is built with quality components, many customers seek further assurance—like the demands of increased uptime. You can choose the level of redundancy your application requires, including: „ Redundant Ethernet network communications „ Redundant controllers „ Redundant power supplies „ Redundant H1 FOUNDATION fieldbus interface and bus power

„ Redundant digital HART I/O „ Redundant MODBUS and other RS485 serial communicatio

Rugged control and field interfaces Built to mount anywhere— minimizing your installation costs and ensuring safety. Meets: „ Class 1, Div. 2 „ Zone 1 and 2 „ Intrinisically safe options „ G3 corrosion resistance „ -40 to 70°C.

Commercial off-the-shelf technologies Proven, low-cost, easily integratable commercial technologies are the fundamental building blocks of the DeltaV system: technologies proven across many industries and known by a wide pool of professionals. „ Windows workstation and server-based PCs „ Ethernet technology „ Bus standards.

Automation–Easy

“The unique design of the DeltaV digital automation system simplifies the installation and commissioning process, enabling us to complete the project five months ahead of schedule ....The quality of the gas is better than the standard of the Grade A specification.” — Mr. Liu Yi Changquing Oil Field Company

You are faced with many options for automating your plants. What separates the DeltaV digital automation system?

Key system services built into the DeltaV software include: „ Peer-to-peer communications „ History services „ Event services „ Alarm services „ Time handling „ Hot expansion services „ Tag look-up services „ Diagnostic services „ On-line upgrades.

Peer-to-peer awareness The DeltaV system keeps a realtime database available to all connected PCs and controllers. Functions difficult or impossible to implement in component-based solutions easily done in the DeltaV system include: „ System-wide alarm management „ Global security by user and function „ System and device diagnostics.

Precision time keeping Across all PC workstations and controllers, precise time can be synchronized to the atomic clock. Time synchronization is available with full redundancy. Precision time means: „ Accurate, system-wide history „ Faster root cause analysis „ Sequence of events is built-in, not a 3rd-party add-on.

ughout the Architecture

Time-stamped and validated at the source Digital automation systems, like the DeltaV system, are built to receive, store and use data timestamped in digital field devices (where supported). With the addition of a GPS time server, these time stamps are within 1msec. Health of the information comes from status data sent by field devices and propagated throughout the DeltaV system. For your traditional field devices, the DeltaV system offers digital Sequence of Events (SOE) interfaces that provide time stamping in the SOE cards to 1msec resolution

User security Built on Windows workstation security, the DeltaV system provides easy, flexible, system-wide security management for all users including operators, engineers, technicians, and other automation users. Based on user login, these keys control both system functionality and span of operator control. Security settings include: „ Operating span of control by plant area „ Alarm limits, tuning parameters change privilege „ Security by both user and by physical location.

The DeltaV control hardware delivers big savings in the installation process. The compact, modular design allows you to cost-effectively meet your process needs. Easy, flexible installation Installation is easy since I/O is automatically auto-sensed when added to the system. No-value engineering is eliminated. DeltaV control hardware is built rugged and flexible to mount almost anywhere. It’s built for: „ Class 1, Division 2 areas „ CENELEC Zone 1/2 areas „ ISA-S71.04-1985 Airborne Contaminants Class G3. Shared Zone 1 Remote I/O Additionally, shared remote I/O is available for Zone 1 and Zone 2 installations. Unlike other remote I/O, shared remote I/O can be shared among several controllers for a greater range of applications and installation flexibility. The DeltaV control hardware has many mounting options available to reduce your installation costs. Some options include: „ DIN-rail field junction box „ High-density cabinet mount „ DIN-rail wall mount „ Skid mount. Hot swappable Unlike other automation solutions, the DeltaV system lets you add system components including controllers, I/O, field devices and workstations while the system is powered and running. You can expand and upgrade your system on the fly with no downtime. Classic field interfaces The DeltaV system also supports a full range of analog, discrete, thermocouple, and RTDs for your existing field devices. Intrinsically safe The DeltaV intrinsically safe field interface subsystem connects intrinsically safe field circuits and field devices into Class 1, Division 1, Zone 1, and Zone 0 hazardous areas for most standard analog input, analog output, discrete input, and discrete output applications. Field power injection Unlike most existing automation systems, the DeltaV system injects field power right at the field interface terminations, significantly reducing installation cost by: „ Eliminating marshalling wiring „ Reducing cabinet or junction box footprint „ Reducing labor for additional terminations










  • CTI 2512 75-Watt AC/DC Power Supply
  • CTI 2510 125 VDC Power Supply
  • CTI 2500-SSB Single Slot Blank Front Panel
  • CTI 2500-R11-A Eleven-Slot Redundant Base
  • CTI 2500P-R16 Sixteen-Slot Base with High-Speed Channel
  • CTI 2500P-R8 Eight-Slot Base with High-Speed Channel
  • CTI 2500P-R4 Four-Slot Base with High-Speed Channel
  • CTI 2541 Redundant Processor Manager Module
  • CTI 2577 Profibus DP Slave Adapter
  • CTI 2573-MOD Serial Interface Adapter with MODBUS
  • CTI 2572-AF Fast Ethernet TCP/IP Adapter with Optical Fiber Connection
  • CTI 2572-A Fast Ethernet TCP/IP Adapter
  • CTI 2572 Ethernet TCP/IP Adapter
  • CTI 2572-B Fast Ethernet TCP/IP Adapter
  • CTI 2576 DeviceNet™ Scanner Module (MATURE)
  • CTI 2500P-ECC1 Ethernet Communications Coprocessor
  • CTI 2500P-JACP Janus Application Coprocessor
  • CTI 2500P-ACP1 Application Coprocessor (MATURE - replaced by 2500P-JACP)
  • CTI 2500P-J450 Janus PAC with 2MB Project Memory
  • CTI 2500-C400 CPU with 3072K User Memory
  • CTI 2500-C300 CPU with 512K User Memory
  • CTI 2500-C200 CPU with 256K User Memory
  • CTI 2500-C100 CPU with 128K User Memory
  • CTI 2500P-J750 Janus PAC with 3MB Project Memory
  • Shinkawa WHF3006M Displacement Converter
  • Shinkawa JBP-220 (P-24-94A / P-24-94B) Circuit Board Module
  • SHINKAWA   WKN-142K5  2-WIRE VIBRATION TRANSDUCER
  • Shinkawa FRP-321 (P-26-54A / P-26-54B) Circuit Board Module
  • Shinkawa IOP-160 (P-25-72A / P-25-72B) Circuit Board Module
  • Shinkawa PK-147B-1 / PK-147A-1 Circuit Board Module
  • Shinkawa CPP-91A Circuit Board Module
  • Shinkawa FRP-177 PCB Module
  • Shinkawa CPP-127 (P-26-74A / P-26-74B) Circuit Board Module
  • Shinkawa FRP-227 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa MDP-104 (P-25-83A / P-25-83B) Circuit Board Controller
  • Shinkawa VK-143P2 High-precision eddy current sensor driver/signal conditioner
  • Shinkawa FRP-226 (P-24-86A / P-24-86B) Circuit Board Module
  • Shinkawa CPP-107A P-22-99A P-22-99B Circuit Board Module
  • SHINKAWA VW-202AL-8 Axial Displacement Sensor
  • Shinkawa VL-202A08L-1A42 Vibration Sensor Transducer Probe
  • Shinkawa VL-202A08L-1A42 Vibration Sensor Transducer Probe
  • Shinkawa FRP-209A & FRP-206 Wire Bonder Circuit Board Module
  • Shinkawa MGP-72 MGP72 P-26-50A P-26-50B Circuit Board Module
  • Shinkawa FRP-249 P-25-1A P-25-1B Circuit Board Module
  • Shinkawa FRP-320 P-26-54A P-26-54B Circuit Board Module
  • Shinkawa FRP-282 P-24-35A P-24-35B Circuit Board Module
  • Shinkawa FRP-338 P-26-54A P-26-54B Circuit Board Module
  • GE IS200AEPBH1B IS200AEPBH1B‑REV‑AA Pitch-Charger Control PCB Board
  • GE IS200EDEXG1ADA EX2100 SCR Trigger Control Board
  • GE 151X1207CK01SA01 IS200EDEXG1A EX2100 SCR
  • GE 151X1233DD02SA02 IS200AEPBH1B - Variant for pitch control charger assembly
  • GE 151X1233DB01SA01 IS200AEPBH1B - 10kW Wind Power Converter
  • GE 151X1233DB01SA01R | IS200AEPBH1B 10KW Converter
  • GE 151X1233DD01SA02 Pitch Battery Charger (109W6931P001)
  • GE 151X1233DD01SA02 Pitch Battery Charger Assy IS200AEPBH1B
  • GE 151X1233DB02SA02 Rev A IS200AEPBH1B Wind Turbine Converter
  • GE 151X1207CK02SA02 SCR 4400 V 1850 A IS200EDEXG1ADA General Electric EX2100
  • Triconex 3723X 32-Channel TMR Analog Input Module with HART
  • SHINKAWA VM-21G  SIGNAL CONDITIONER SOCKET
  • SHINKAWA VM-21R REVOLUTION SIGNAL CONDITIONER
  • SHINKAWA VM-21T DISPLACEMENT INPUT THRUST SIGNAL CONDITIONER
  • SHINKAWA VM-21D 6-WIRE LVDT SIGNAL CONDITIONER
  • SHINKAWA VM-21P 3-WIRE LVDT SIGNAL CONDITIONER
  • SHINKAWA VM-21A  VIBRATION SIGNAL CONDITIONER
  • SHINKAWA VM-21K DISPLACEMENT INPUT VIBRATION SIGNAL CONDITIONER
  • SHINKAWA VM-25S01 CONDITION MONITORING SYSTEM
  • SHINKAWA VM-25 CONDITION MONITORING SYSTEM
  • SHINKAWA VM-772B DEVICE CONFIG
  • SHINKAWA VM-771B MCL VIEW
  • SHINKAWA VM-76B INSTRUMENT RACK
  • SHINKAWA VM-75B POWER SUPPLY MODULE
  • SHINKAWA VM-742B NETWORK COMMUNICATION MODULE
  • SHINKAWA VM-741B LOCAL COMMUNICATION &  PHASE MARKER MODULE
  • SHINKAWA VM-722B 9-CHANNEL RELAY MODULE
  • SHINKAWA VM-707B AERODERIVATIVE GAS TURBINE  MONITOR MODULE
  • SHINKAWA VM-706B ROD DROP MONITOR MODULE
  • SHINKAWA VM-705B 18-CHANNEL TEMPERATURE   MONITOR MODULE
  • SHINKAWA VM-704B TEMPERATURE MONITOR MODULE
  • SHINKAWA VM-702B ABSOLUTE VIBRATION  MONITOR MODULE
  • SHINKAWA VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE
  • SHINKAWA MODEL VM-5X INTERFACE UNIT
  • SHINKAWA MODEL VM-5W2 DUAL POWER SUPPLY INSTRUMENT RACK
  • SHINKAWA MODEL VM-5H4  INSTRUMENT RACK (for VM-5Z5.6.7)
  • SHINKAWA MODEL VM-5G  SINGLE UNIT   INSTRUMENT RACK
  • SHINKAWA MODEL VM-5Z5,6,7  POWER SUPPLY UNIT
  • SHINKAWA MODEL VM-5Y1,2,3 RELAY MODULE UNIT
  • SHINKAWA MODEL VM-5P3 PHASE MARKER UNIT
  • SHINKAWA MODEL VM-53 DUAL COMMUNICATION UNIT
  • SHINKAWA MODEL VM-52 BOTTOM HOLD MONITOR
  • SHINKAWA MODEL VM-51 ROD DROP MONITOR
  • SHINKAWA MODEL VM-5R TACHOMETER
  • SHINKAWA MODEL VM-5S DUAL TACHOMETER
  • SHINKAWA MODEL VM-5A DUAL VALVE
  • SHINKAWA MODEL VM-5E DUAL CASE
  • SHINKAWA MODEL VM-5L COMPLEMENTARY INPUT
  • SHINKAWA MODEL VM-5N RAMP DIFFERENTIAL
  • SHINKAWA MODEL VM-5D DUAL DIFFERENTIAL
  • SHINKAWA MODEL VM-5T DUAL THRUST MONITOR
  • SHINKAWA MODEL VM-5C ECCENTRICITY MONITOR
  • SHINKAWA MODEL VM-5M DUAL PATH MONITOR
  • SHINKAWA MODEL VM-5B DUAL ACCELERATION MONITOR
  • SHINKAWA MODEL VM-5U DUAL SEISMIC MONITOR
  • SHINKAWA MODEL VM-55 VIBRATION MONITOR
  • SHINKAWA VM-742B1-5 VIBRATION MONITORING SYSTEM CARD
  • Shinkawa PSP-17B P-24-64A P-24-64B Circuit Board Module
  • SHINKAWA MGP-67 PCB
  • Shinkawa JBP-278 P-22-48A-1 P-22-48B-1 Circuit Board Module
  • Shinkawa VM-721B 18-CHANNEL RELAY MODULE
  • Shinkawa FRP-337 P-26-54A P-26-54B Circuit Board Module
  • Shinkawa CPP-111 P-25-59A P-25-59B Circuit Board Module
  • Shinkawa WKN-142K2-2 Vibration Transmitter
  • SHINKAWA VL-202A08L-1012 Rotor Position Monitor Probe Sensor
  • Shinkawa CPP-128 P-26-74A P-26-74B Circuit Board Module
  • Honeywell 51402755-100 PROCESSOR CARD
  • Honeywell 51107595-100 Power
  • HONEYWELL 51304544-100 Control Board
  • HONEYWELL 51109919-100 BOARD
  • HHoneywell 51204160-175 Digital Input Module
  • Honeywell 51304754-150 High Level Analog Input Module
  • HONEYWELL 51304690-100 DIGITAL INPUT CARD
  • Honeywell 51401635-150  COMM CONTROL
  • HONEYWELL 51204174-175 MC-TAOY 52 ANALOG OUTPUT BOARD
  • HONEYWELL  51400596-100
  • HONEYWELL 51401291-100 board card
  • HONEYWELL 51401642-150 I/O LINK MODULE
  • Honeywell LCN‑E Hub Power Supply 38500148‑300
  • Honeywell LCN‑E Hub redundant 38500143‑202 Twisted‑pair LCN
  • Honeywell LCN‑E Hub non‑redundant,38500143‑102