Features 

• Protocol conversion gateway for substation automation: 

- Process communication: LON-LAG, SPA, IEC 60870-5-103, IEC 61850-8-1, Modbus serial, Modbus TCP, DNP3 serial, DNP3 TCP - Remote communication: IEC 60870-5- 101, IEC 60870-5-104, DNP 3.0 Serial, DNP 3.0 LAN/WAN, SPA Router, External OPC Client (DA, AE) • True IEC 61850 communication gateway: 

- IEC 61850-6 

- Substation Configuration Language (SCL) - IEC 61850 -7 

- Communication modeling and cross-referencing between protocols - IEC 61850-8-1 - Mapping for MMSTCP/IP – Ethernet 

• Configuration: - Efficient and intuitive configuration tool - Cross-referencing between protocols based on the IEC61850-7 models - Drag-and-drop protocol mapping to map complete structures from the source data - Efficient handling of large amounts of data in list views - Tooltips - Remote configuration and administration 

• Communication redundancy (requires optional LAN card) - IEC 62439/PRP (parallel redundance protocol) - SFT (switch fault tolerance) 

• Extensive support for commissioning and diagnostics: - Online diagnostics for different components - Communication diagnostic counters on the network and device level - Real time process data monitoring and controlling for all devices and protocols - Source data monitoring and simulation: - Testing the data mapping for NCCs also with no online IEDs - Simulating complete IEDs - Communication diagnostic event list for all devices and protocols: - Resembles a high level protocol analyser - Monitors the reported values and events and the received control commands 

• Web server for diagnostic information: - Requires only a web browser and a TCP/IP connection - no pre-installations 

• MNS iS connectivity - Connectivity to ABB’s Low Voltage Motor Control Center MNS iS with an OPC server in COM600. COM600 receives data from the MNS iS devies and provides HMI and gateway functionality 

• Security: - User authentication - Individual user accounts - Password authentication - Role-based access control - Host-based firewalls - Communication encryption HTTPS

Application COM610 3.2 is a communication gateway that maps signals between the protection and control IEDs in industrial or utility substations and higher-level systems such as Network Control Centres (NCC) or Distributed Control Systems (DCS). COM610 3.2 sends information for monitoring and controlling the process to NCC and DCS and receives process control commands from them. COM610 3.2 also handles system co-ordination tasks, such as the dynamic assignment of control command authorisation and communication supervision. COM610 3.2 is typically connected to a NCC via a telecontrol protocol, or to a DCS using the OPC Server/Client technology. You can use different protocols to connect process devices to COM610 3.2. COM610 3.2 is a true IEC 61850 gateway and supports all applicable IEC 61850 parts. Fig. 1 displays an overview of a typical utility system with the COM610 Gateway. Fig. 2 displays an industrial system overview.

Application (cont´d) 5 The LON-LAG protocol uses a specific board to connect the fibres, both plastic and glass. COM610 3.2 can have one board, that is, one LON line. It is possible to extend COM610 3.2 by increasing the number of Ethernet interfaces thus increasing the number of Ethernets lines. Connectivity Packages To make the configuration of COM610 3.2 more efficient, Connectivity Packages are available for ABB’s protection and control IEDs. A Connectivity Package includes descriptions of data and signals available in the IED, and the descriptions are used to automatically configure the master communication in the COM610 3.2 gateway. Connectivity Packages for some IEDs are already available, and more will be released in due couse. At present the following Connectivity Packages are available: - REF 541/3/5, REM 543/5, RET 541/3/5 - REF 542plus - REX 521 - RE_610 - SPACOM (Conn Pack v. 2.0 supports SPAJ 140, SPAJ 141, SPAJ 142, SPAJ 144, SPAD 346, SACO 16D1, SACO 16D2, SACO 64D4) COM610 gateway unit’s configurability and functionality depends on the type of communication protocol used for communication between the COM610 and the IEDs. For more details, please refer to the document “Protocols versus Functions for IEDs”, 1MRS756223

The COM610 gateway consists of the OPC Data Access (DA, AE) server and client components. The OPC Servers provide the master/client protocol stacks access to the data in the devices connected with the protocol. The slave/server protocol stacks use the OPC Clients to provide the external systems access to the data available in the OPC Servers.


Available protocols The table below displays the protocols supported by COM610 Gateway. New protocols will be available according to the market demands. The process communication uses the master protocols and the upper level communication uses the slave protocols. For more detailed information on the protocols, refer to the User’s guides listed in References.


System requirements for the Communication Engineering Tool Hardware requirements The Communication Engineering Tool runs on Microsoft® Windows® XP. A PC capable of running this program is usually sufficient also for running the Communication Engineering Tool. Microsoft® .NET Framework 2.0 is required for running the Communication Engineering Tool. It is automatically installed during the installation of the Communication Engineering Tool if it is not already available on the PC. • Free hard disk space required: minimum 500 MB, recommended 1 GB. Technical data Hardware Design • Ruggedised mechanics - No moving parts - no fans, no hard disks • System - Intel® Pentium® M 1.6 GHz - 1 GB SDRAM System Memory - 2 GB Industrial SSD Compact Flash memory • Power supply units: - 76-240 V dc • Interfaces - 3 RS 232 serial ports - 1 RS 232/485 serial port - 2 10/100Base-TX RJ-45 connector - 4 USB 2.0 ports - Optional PCI extensions: - 1 LON interface (Operating temperature 0°C - +70°C) - 8 RS232/485 serial interfaces (Operating temperature 0°C - +55°C) - 2 10/100/1000Base-TX RJ-45 connectors (Operating temperature 0°C - +60°C) • Mechanics and Environment: - Operation -25°C to +70°C - Storage -40°C to +70°C - Dimensions (without fastening brackets): 214 mm (W) x 122.5 mm (H) x 313 mm (D) - Net weight: 6.8 kg - Degree of protection: IP 4x - Operating humidity: 5-95% at +40°C, non-condensing - EMC CE/FCC class B - Anti-vibration and anti-shock tests.

  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • SEL SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO HSL-4XMO-TB-D103 HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • AADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink  PICMG Single Board Computers  NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 industrial control motherboard
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC
  • ADLINK/AMPRO CM-435-v2/CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Technology 51-37111-0C1 PCB Interface Card
  • Adlink Centralized Motion Controllers PCI-8164
  • ADLINK PCI-7230/33/34 32-CH Isolated DIO PCI Cardsrd
  • ADLINK NUPRO-E320DV/NUPRO-E320 industrial control motherboard
  • Adlink PCI-8154 Advanced 4-axis Servo & Stepper Motion Controller
  • Adlink cPCI-3534/3538-S Series 4/8-port Asynchronous Serial Communications Modules
  • ADLINK Adlink Digital I/O PCI-7396
  • ADLINK 6U Rear Transition Modules cPCI-R6700 Series
  • ADLINK cPCI-6700B Industrial Control Board
  • ADLINK NuPRO-965/ NuPRO-965LV PICMG Single Board Computers
  • ADLINK HSL-DI16DO16-M-NN 16-CH Discrete Input 16-CH Discrete Output Module
  • Adlink cPCI-6770 6U CompactPCI 2.0 Blades
  • ADLINK NuPRO-598 REV A1 INDUSTRIAL CONTROL MOTHERBOARD
  • ADLINK PCI-7200 PCI Motion Control Card Acquisition Card 51-12001-0C20
  • ADLINK TECHNOLOGY EOS-1200/M4G/SSD32G(G) Industrial Systems
  • ADLINK Centralized Motion Controllers PCI-8134
  • ADLINK cPCI-HR6847E/M2G-1 COMPACT PCI BOARD
  • ADLINK PXIE-8638 BUS EXPANSION MODULE
  • ADLINK cPCI-6910 6U CompactPCI 2.0 Blades
  • Adlink NuPRO-E42 51-41808-0A30 Industrial Motherboard
  • ADLINK IH61-AA400-A4A1E (IMB-M40H) Industrial Motherboard
  • ADLINK PCIe-GIE64+ GigE Vision Frame Grabber Card
  • ADLINK MXC-6322D(G) Industrial Fanless Computer working